Description
The Edan VE-300 Veterinary EKG (#VE-300) includes a built-in thermal printer and a rechargeable lithium battery. It is simple and easy-to-use and works as a single or 3 channel ECG for animals with interpretive analysis included in the form of automatic measurement calculation. It is also extremely portable thanks to a lightweight design and a built-in handle.
Warranty: 2 Years.
Features
Edan VE-300 Veterinary EKG Features
- 3-channel display on 3.5 inch LCD color screen.
- Complete digital design.
- LCD display waveforms with configurable parameters.
- Lead-Off detection and display.
- Complete digital filter to avoid baseline drift, AC, and EMG interference.
- Automatic ECG parameter measurement.
- Veterinary five-lead ECG cable and alligator clips.
- AHA/IEC color coding for lead identification.
- The baseline is automatically adjustable.
- Portable design with built in handle.
- Simple, one-button operation.
- Well designed touch panel.
- Built-in rechargeable Lithium battery and AC/DC supply.
- Built-in thermal printer.
- High resolution thermal printing.
- Capable of directly printing out with external inkjet printer.
- Copy mode prints additional copies of the last Auto ECG.
- Select your printing format: 1 lead, 3 lead, rhythm lead, or average template.
- Waterproof mambrane keyboard.
- Input/Output and RS-232 port and Ethernet network capability.
- USB Interface for patient data transferring to flash disk.
- Auto/manual operation.
Specifications
Edan VE-300 Veterinary EKG Specifications
- Input Circuit: Protection from defibrillation.
- Lead: Standard 7 leads.
- Acquisition: 7 leads simultaneously.
- A/D Resolution: 12 bits.
- Measurement Range: ±5mVpp.
- Time Constant: ≥3.2s.
- Frequency Response: 0.05Hz ~ 150Hz.
- Calibration Voltage: 1mV ±3%.
- Sensitivity: 2.5, 5, 10, 20 (mm/mV).
- Input Impedance: ≥50m Ω.
- Input Circuit Current: ≥50nA.
- Noise Level: ≥15µVp-p.
- Anti Baseline Drift: Automatic.
- Patient Leakage Current: ≤10µA (220V~240V).
- Patient Auxiliary Current: ≤0.1µA (DC).
- Filters:
- EMG Filter: 25Hz/35Hz/45Hz/OFF.
- DFT Filter: 0.05/0.15/0.25/0.5Hz.
- Lowpass Filter: 150Hz/100Hz/75Hz.
- AC Filter: 50Hz/60Hz.
- CMRR: >100dB.
- Recording Modes: Auto/Manual/Rhythm/OFF/USBPRT.
- Rhythm Lead: Single lead selectable.
- Safety Standard: IEC 1/CF.
- Power Supply:
- AC: 100V-115V/220V-240V, 50/50Hz.
- Built-in rechargeable Li-ion battery.
- More than 3 hrs continuous work under battery supply.
- Thermal Recorder: Thermal dot array, 8 dots/mm vertical.
- Recording Paper: 80mm x 20m.
- Recording Speeds: 5mm/s, 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s (±3%).
- Dimensions: 300mm x 260mm x 75mm.
- Weight: 2.5kg (with battery).
- Display: 192 x 64 dots LCD.
- External Input/Output:
- Input: ≥100kΩ; Sensitivity 10mm/V ±5%.
- Output: ≤100Ω; Sensitivity 1VmV ±5%.
- Communication Interface: Ethernet, RS232, USB.