Description
The Quinton Q-Stress Cardiac Stress System includes a PC workstation with keyboard and mouse configured with cardiac stress application software (Version 6), 24" wide-screen color monitor, Z200+ thermal printer (with two starter packs of full-grid 8" paper), AM12Q Wired Acquisition Module with Trigger Module, isolation transformer, system cart with base, keyboard tray, storage shelf, large storage drawer, side storage pocket, 10-lead ECG patient cable with leadwires, stress belt to support the patient cable, local area network (LAN) support, and US/Canada power cord.
Warranty: 13 Months - Parts and Labor.
The Q-Stress is designed to perform a variety of functions, from routine exams to complex cardiac evaluations. The Cardiac Stress System is a customizable, scalable platform offering highly flexible configurations that can be adapted for each application, user, and site.
Features
Quinton Q-Stress Cardiac Stress System Features
- VERITAS algorithm offers exceptional accuracy in real-time ST-Segment Monitoring, arrhythmia detection, and resting ECG interpretation.
- Source Consistency Filter removes noise and baseline artifact offering an accurate picture of the ECG waveform.
- Real-time full disclosure lets you review historical ECG data throughout the exam.
- Connected workflows help you improve patient care and information access.
- Flexible user configurations tailor over-reads, billing, and data storage to your workflow.
- 12-lead ECG interpretation for adults, adolescents, and children.
- Communicate bidirectionally using HL7 or DICOM to reduce errors while providing an electronic, editable format to your team.
- Label, store, print, and review events on the fly and include them in final report.
- Wireless Acquisition Module (WAM) digitally transmits ECG data to help make exams easier and more comfortable for patients.
- AM12Q Wired Acquisition Module with Trigger Module for TTL/analog signal output and low voltage treadmill.
Specifications
Quinton Q-Stress Cardiac Stress System Specifications
- Power Requirements: 100/120 VAC, 50/60 Hz, 2.5 A nominal; 200/240 VAC, 50/60 Hz, 1.3 A nominal.
- Operating System: Microsoft Windows 10 Pro 64-bit.
- Protocols:
- Standard: Bruce, Modified Bruce, Modified Balke, Naughton, USAF/SAM 2.0, USAF/SAM 3.3, Ramped-low, Ramped-medium, Ramped-high, Time-Ramp, and METs Ramp, Astrand (ergometer), pharmacological, and more.
- Custom: Up to 100 custom protocols assorted.
- Front-End Module:
- AM12Q with AHA 10-electrode pinch or snap connectors.
- AM12Q with IEC 10-electrode-pinch or snap connectors.
- WAM module for wireless ECG acquisition with AHA 10-electrode-pinch connectors.
- WAM module for wireless ECG acquisition with IEC 10-electrode-pinch connectors.
- ECG:
- Lead Groups: Cabrera 12-lead.
- Display Format: 3, 6, 6 x 2, or 12 x 1 channels.
- Performance Standard: IEC 60601-2-25: gain accuracy, frequency response, CMRR, system noise, dynamic range, and input impedance.
- Display and Analysis Filters: Source Consistency Filter (SCF), muscle artifact, baseline wander, 40 Hz low pass, line frequency.
- Reports:
- In-Test: 12-Lead, average beat report, 1-page write screen, continuous rhythm, arrhythmia events.
- Final: Summary, tabular, worst case, average beats by stage or by minute, in-test ECG reports, trend graphs and peak exercise. Reports can be viewed, printed, saved in PDF format, emailed or exported in PDF, XML, and DICOM.
- Custom: Unlimited customizable reports.
- Outputs: TTL pulse and analog signals for QRS detection synchronization using any ECG lead.
- External Device Interfaces:
- Treadmills: Trackmaster TMX428 and TMX425.
- Ergometers: Compatible with Ergoline and Lode communication protocols.
- Blood Pressure Monitors: SunTech Tango+ and Tango M2.
- Printers:
- Thermal: High-resolution Z200+ with automatic feed and continuous printing capability (requires additional network port).
- Laser: Optional compact HP M501dn laser printer with high-quality print (recommended).
- Paper: 8.5" x 11" (letter) or 210 mm x 300 mm (A4).
- Network Interface: Microsoft-compatible networking for storage, distribution, and email; 100 Mbps connection or better is required.
- Paper: Smart (210 x 280 mm), perforated Z-fold thermal cued paper with full grid; 250 sheets stored in paper tray.
- Export/Communication Protocol/Format: TCP/IP, PDF, XML, HL7, DICOM.
- Remote Technical Service Interface: Remote service increases system uptime availability and decreases the user's requirement to assist the troubleshooting process. Available via network or desktop connections (only in the US).
- Display: 24" (609 mm) flat panel LCD (24" touchscreen display is optional).
- System Dimensions: 22.5" (D) x 24.6" (W) x 62.5" (H) (57 cm x 63 cm x 159 cm).
- Weight: Approximately 270 lb (122.5 kg).
Configurations
Quinton Q-Stress Cardiac Stress System Configurations
- #QS6-MLTCX: Mid Level - With LCD Screen and PDF/XML Connectivity.
- #QS6-MLTC1: Mid Level - With LCD Screen, Treadmill, and PDF/XML Connectivity.
- #QS6-ATTDX: Pro Level - With Touch Monitor and DICOM Connectivity.
- #QS6-ATTD1: Pro Level - With Touch Monitor, Treadmill, and DICOM Connectivity.
Accessories
Quinton Q-Stress Cardiac Stress System Accessories
The following accessories are compatible and commonly purchased with the Q-Stress Cardiac Stress System:
- #4100-036-51: WAM Kit with AHA Short Lead Set.
- #9100-026-60: Thermal Paper - 8.5" x 11".
- #9911-023-33: SunTech Tango Mount Kit for use with ELO 24" Touch Monitor.
- #9922-017-52: SunTech Tango+ and Tango M2 SpO option.
- #9922-019-50: SunTech Tango M2 BP Monitor Kit.
- Q-Stress Protection+ Smartcare Service 3-Year Program:
- #S9-QS-PROPLUS-PS: For Standard Systems.
- #S9-QSTM-PROPL-PS: For Systems with Treadmill.