Maxtec MAX-1 Oxygen Cell

(0)
Regular price
$133.00
Sale price
$133.00
Regular price
$108.00
Sold out
Unit price
Quantity must be 1 or more

Description

The Maxtec MAX-1 Oxygen Cell is an FiO (Fraction of Inspired Oxygen) Sensor. It is compatible with a variety of systems and is primarily used with anesthesia machines, ventilators, O monitors, O analyzers; check the Configurations tab for specific compatibility information.

Warranty:

  • Generic Equivalent: 18 Months - Free of Manufacturing Defects.
  • Original: 1 Year Shelf Life.

Note: Can only be shipped within the U.S.

Specifications

Maxtec MAX-1 Oxygen Cell Specifications

  • Electrical Interface: Gold plated slip rings.

#G0-010 (Generic Equivalent) specific:

  • Response Time: < 12 seconds.
  • Latex-free.
  • Non-sterile.
  • Weight: 0.2 lb.
  • Certifications: FDA, CE, ISO10993-1, 5, 10:2003E, TUV, RoHS Compliant.

#R113P90 (Original) specific:

  • Range of Measurement: 0 to 100%.
  • Output Range: 14 to 20 mV.
  • Zero Offset: ≤ 0.30 mV.
  • Response Time: ≤ 17 seconds.
  • Linearity: < 3% full scale.
  • Expected Lifetime: > 500,000 %O hours.
  • Operational Temperature Range: 10 to 40 °C.
  • Storage Temperature Range: -20 to 50 °C.
  • Humidity Range: 0 to 90% RH, non-condensing.
  • Ambient Pressure Range: 700 to 1250 mbar.
  • Interference: Per EN ISO 80601-2-55.

Configurations

Maxtec MAX-1 Oxygen Cell Configurations

  • #G0-010: Generic Equivalent (Manufactured by Cables and Sensors):
    • Compatible with Datex-Ohmeda models such as the 125, 205, 51, 510, 5100, 5125, 5140, 5200, 5250, 5250 RGM, 5400, 7200, 7800, 7810, Excel 210-7800, Excel 7800, Modulus 4700, Modulus 7800, Modulus II 7810, Oxicap, S5172802.
    • OEM Part Number Cross References: Analytical Industries: PSR-11-915 / Biotest: S101 / CR: R-15 / Ceramatec: CAG-1 / City Technologies: MOX-6 / Datex-Ohmeda: 0237-2034-700 / Draeger - Air Shields: C-100 / Draeger: 6803290 / Envitec: OOM101 / Hamilton Medical: HM-10, HM-13 / Hudson RCI: 5556 / Integral Process: 65001 / MSA: 655264, 655263 / Mercury Medical: 10-103-17 / Nuova: E-15/0 / Philips: 15201A / Sensidyne: SV-14A / SensorTech: ST-10 / Sensoronics - Pacifitech: SS-10A, PT-10 / Teledyne: #C-41131 / VTI: VT1272, 101272, 100352.
  • #R113P90: Original (Manufactured by Maxtec):
    • Replacement For: Analytical Industries: PSR-11-915 / Datascope: Multinex Analyzer / GE Datex-Ohmeda: 0237-2034-700 Excel Modulus, 5250 RGM, 5150 Handheld Monitor / GE Ohmeda: 5120, 5100, 5250 RGM, 4700 Oxicap, 7800, 5125, 5150, Handheld Monitor, 0237-2034-700, Excel Modulus / Hewlett Packard: 15201A / Mercury Medical: 10-103-07 / Pacifitech: PT-10 / Teledyne: R15 #C-4113 / Teleflex (Hudson): 5556 / VTI: 100352, 101272, 100352.

Literature

Open Full Site: mfimedical.com