Frequently asked questions
Does the oxygen cell offer broad system compatibility?
Yes, the Maxtec MAX-1 Oxygen Cell is designed for extensive compatibility across various medical gas monitoring systems as a critical FiO2 (Fraction of Inspired Oxygen) sensor.
It is engineered to integrate seamlessly with:
- Anesthesia machines
- Ventilators
- O2 monitors
- O2 analyzers
This broad utility is especially reinforced by the Generic Equivalent configuration (#G0-010), which cross-references numerous OEM part numbers from leading manufacturers such as Datex-Ohmeda, Draeger, and Philips.
Does the Generic Equivalent sensor meet strict compliance standards?
Yes, the Generic Equivalent configuration of the MAX-1 Oxygen Cell is extensively certified and meets strict international compliance standards, ensuring reliability for critical medical applications.
Key certifications and features include:
- FDA and CE Marked for regulatory approval.
- RoHS Compliant (Restriction of Hazardous Substances).
- TUV Certified for quality and safety.
- Adherence to comprehensive ISO10993 biocompatibility standards (1, 5, and 10:2003E).
- The sensor is manufactured to be Latex-free.
This variant also includes an extended 18-month warranty against manufacturing defects, providing added assurance.
What is the fast response time for this oxygen sensor?
The response time for the MAX-1 Oxygen Cell varies based on the configuration you choose, but both options ensure rapid results crucial for continuous patient monitoring:
- Generic Equivalent (Cables and Sensors): Features a rapid response time of less than 12 seconds.
- Original (Maxtec): Has a maximum response time of $\le 17$ seconds.
While the Original unit has a slightly longer response time, it offers high durability, rated for an operational lifetime exceeding 500,000 %O₂ hours.
Are there different sensor configurations available?
Yes, the Maxtec MAX-1 Oxygen Cell is available in two distinct, Factory New configurations—the Original unit manufactured by Maxtec and a Generic Equivalent manufactured by Cables and Sensors—allowing selection based on performance requirements and budget.
Both cells are essential $\text{FiO}_2$ sensors with a reliable gold-plated slip ring electrical interface. Key differences include:
| Feature | Original Maxtec Unit (#R113P90) | Generic Equivalent (#G0-010) |
|---|---|---|
| Manufacturer/Origin | Maxtec (Germany) | Cables and Sensors (US) |
| Operational Longevity | Excellent longevity (> 500,000 %$\text{O}_2$ hours) | Not specified |
| Response Time | $\le$ 17 seconds | Faster (< 12 seconds) |
| Compliance | Per EN ISO 80601-2-55 | FDA, CE, TUV, RoHS Compliant |
| Material/Sterility | Standard | Latex-free and Non-sterile |
| Warranty | 1 Year Shelf Life | Longer (18 Months) |
What is the impressive lifetime of the original oxygen cell?
The Original (Maxtec) configuration is built for maximum durability and reliable performance. It boasts an impressive expected operational lifetime of more than 500,000 % O₂ hours, which is a key advantage for critical care and operating room environments.
What is the full measurement range of the Original MAX-1?
The Original Maxtec MAX-1 Oxygen Cell (Part #R113P90) is engineered to cover the entire clinically necessary spectrum of oxygen measurement. Its key performance specifications include:
- Measurement Range: 0 to 100% oxygen concentration.
- Expected Lifetime: Exceeds 500,000 %O2 hours.
- Precision: Features high accuracy with a linearity of less than 3% full scale and a zero offset of
≤ 0.30 mV. - Response Time:
≤ 17 seconds.
What is the output range for the Original Maxtec cell?
The Original Maxtec MAX-1 Oxygen Cell (Part #R113P90) is designed for reliable and precise performance in critical monitoring environments.
Key specifications for this configuration include:
- Output Range: 14 to 20 mV
- Measurement Range: 0 to 100% FiO2
- Response Time: Rapid, at less than or equal to 17 seconds
- Linearity: Excellent, at less than 3% full scale
- Zero Offset: Minimal, at less than or equal to 0.30 mV
Furthermore, this sensor offers exceptional durability, featuring an expected operational lifetime exceeding 500,000 %O2 hours.
What is the sensor's operational temperature range?
The operational temperature range for the Original Maxtec MAX-1 Oxygen Cell variant is 10 to 40 °C.
For reference, the Original unit is also specified for optimal performance within the following environmental conditions:
- Storage Temperature Range: -20 to 50 °C
- Humidity Range: 0 to 90% RH, non-condensing
- Ambient Pressure Range: 700 to 1250 mbar
What is the storage temperature range?
The specified storage temperature range applies to the Original Maxtec MAX-1 Oxygen Cell variant. It is rated for safe storage between -20 to 50 °C.
What is the Original Maxtec humidity range?
The Original Maxtec MAX-1 Oxygen Cell is engineered for reliable performance across a wide range of humidity levels. The operational specification is:
- Operational Humidity Range: 0 to 90% RH (Relative Humidity)
This range requires the environment to be non-condensing.