Description
This Maxtec MAX-12 O Cell is an FiO2 (Fraction of Inspired Oxygen) Sensor that is compatible with a variety of systems. Primarily used with Ventilator Machines and O Monitors/ Analyzers; check below for specific compatibility information.
*Note: Can only be shipped within the U.S.
Warranty: 16 Month Shelf Life.
Maxtec KOH Oxygen Sensors Safety Data Sheet
Maxtec MAX-12 Oxygen Cell Specifications Sheet
*Note: Can only be shipped within the U.S.
Warranty: 16 Month Shelf Life.
Maxtec MAX-12 O Cell Specifications:
- Compatible with:
- Analytical Industries.
- Bird Avea Ventilator.
- Citi Technologies.
- Datascope 0600-00-0002.
- Envitec.
- EME Hamilton Medical: Viasys Arabella, Galileo, Raphael, Aladdin, 51254, Carefusion Viasys Avea 16448.
- Emerson Infant Flow.
- Datex-Ohmeda.
- Hamilton Instruments: G5, Raphael, Arabella, Multinex, Analyser, Aladdin, Galileo, 51254, 396008, 396009.
- Hudson: 5556.
- IMT: PF300.
- Infrasonics: Adult Star 601T.
- Maxtec.
- MSA.
- Nuova.
- Puritan Bennett: NP 840 Ventilator 4-074925-00.
- Sensidyne: Acutonic Hi Frequency Jet Ventilator, 00M102.
- Siemens: Servo 900C, 900D, 900E, Servo 300, 300A, SV 300, Servo 700, 710, SV900, V710, C/D, 9000, Infinity Delta.
- Spacelabs: Capnograph, 90513.
- Taema: Cesar 2, Horus 4, YR049700.
- Teledyne TED 160, TED 190.
- Viamed.
- Equivalent to:
- Analytical Industries: PSR-11-917-J, PSR-11-917-M
- Ceramatec: CAG-12.
- City Technologies: MOX-9, R-24.
- Envitec: OOM-202.
- Datex Ohmeda: 6051-0000-222.
- Hamilton Medical: 396008, 396009, HM-12.
- Hudson RCI: 5566, V-12.
- Integral Process: 65016.
- International Technologies: M-04.
- IMT Medical: PF300.
- Maxtec: MAX-12 R109P45.
- Mercury Medical: 10-103-06.
- MSA: 472062,470644.
- Nuova: E-17/M.
- Ohio Medical: 472062, 470644.
- Pacifitech: PT-12A.
- Siemens: 9004979-E347E, 6419332-E380E.
- Sensidyne: SV-12A.
- SensorTech: ST-01.
- Spacelabs: 90513.
- Taema: YR049700.
- Teledyne: R24 MED, B-62321.
- Ventrex: V-12A.
- Viamed: R-24Med.
- VTI Vascular Technology: 103100.
- G0-040 (Maxtec Equivalent) Specifications:
- Response Time: < 12 seconds.
- Connector Type: 3-Pin Molex gold plated.
- R109P45 (Maxtec) Specifications:
- Output: 14.5 ± 1.5 mV.
- Response Time: ‰¤ 13 seconds.
- Linearity: < 2% relative.
Maxtec MAX-12 O Cell Configurations:
- G0-040: MAX-12 Cell Equivalent manufactured by Cables and Sensors.
- R109P45: Maxtec MAX-12 Cell manufactured by Maxtec.
Maxtec MAX-12 O Cell Literature:
Maxtec KOH Oxygen Sensors Safety Data Sheet
Maxtec MAX-12 Oxygen Cell Specifications Sheet