Description

The B. Braun Surecan Safety II Port Access Needle (100/Case) is a highly-pressure-resistant needle for port access. Safety engineered for accessing implanted intravenous ports, the Safety II Port features non-coring and angled needles that are suitable for power injections up to 325 psi. Designed with the idea of reducing needlestick injuries, it also features a manually activated safety mechanism that is designed to deploy upon needle removal and to shield the tip. It is available with or without a Y-site and pre-attached Caresite luer access device.

Features

B. Braun Surecan Safety II Port Access Needle Features

  • A green dot appears through the clear bottom plate when the safety mechanism is successfully engaged.
  • Low profile foam pad helps with the placement of a securement dressing.
  • The nonabsorbent pad and closed cell materials reduce the potential for needlestick injuries.
  • Flexible and ergonomic wings keep handling secure throughout the insertion and removal of the needle.
  • The small, transparent, and round based plate increases stability and helps you visualize the placement of the needle.
  • Available with or without a Y-site and pre-attached Caresite luer access device.

Specifications

B. Braun Surecan Safety II Port Access Needle Specifications

SKU
Total Shelf Life
Ordering Unit
Units per Case
Dimensions per Case
Shipping Weight per Case
#4447001-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447002-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447004-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447006-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447007-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447008-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447009-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447011-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447012-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447013-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447044-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447000-02 60 Months Case 100 24.016" x 12.205" x 6.693" 4.409 lb
#4447043-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447005-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447010-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447046-02 36 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447047-02 36 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447051-02 60 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447052-02 36 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447055-02 36 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447056-02 36 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447045-02 36 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447058-02 36 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447050-02 36 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
#4447059-02 36 Months Case 100 24.016" x 12.598" x 6.693" 4.409 lb
  • DEHP Information: Not made with DEHP.
  • Latex Information: Not made with natural rubber.
  • Sterile: Yes.
  • Sterilization Method: EO.

Configurations

B. Braun Surecan Safety II Port Access Needle Configurations

  • #4447001-02: 19 G x 0.8 in (20 mm).
  • #4447002-02: 19 G x 1 in (25 mm).
  • #4447004-02: 19 G x 1.5 in (38 mm).
  • #4447006-02: 20 G x 0.8 in (20 mm).
  • #4447007-02: 20 G x 1 in (25 mm).
  • #4447008-02: 19 G x 1.3 in (32 mm).
  • #4447009-02: 20 G x 1.5 in (38 mm).
  • #4447011-02: 22 G x 0.8 in (20 mm).
  • #4447012-02: 22 G x 1 in (25 mm).
  • #4447013-02: 22 G x 1.3 in (32 mm).
  • #4447044-02: 22 G x 0.5 in (12 mm).
  • #4447000-02: 19 G x 0.6 in (15 mm).
  • #4447043-02: 20 G x 0.5 in (12 mm).
  • #4447005-02: 20 G x 0.6 in (15 mm).
  • #4447010-02: 22 G x 0.6 in (15 mm).
  • #4447046-02: with Caresite Y Injection Site 19 G x 0.8 in (20 mm).
  • #4447047-02: with Caresite Y Injection Site 19 G x 1 in (25 mm).
  • #4447051-02: with Caresite Y Injection Site 20 G x 0.8 in (20 mm).
  • #4447052-02: with Caresite Y Injection Site 20 G x 1 in (25 mm).
  • #4447055-02: with Caresite Y Injection Site 22 G x 0.8 in (20 mm).
  • #4447056-02: with Caresite Y Injection Site 22 G x 1 in (25 mm).
  • #4447045-02: with Caresite Y injection site 19 G x 0.6 in (15 mm).
  • #4447058-02: with Caresite Y injection site 20 G x 0.5 in (12 mm).
  • #4447050-02: with Caresite Y injection site 20 G x 0.6 in (15 mm).
  • #4447059-02: with Caresite Y injection site 22 G x 0.5 in (12 mm).

Frequently asked questions

Is this used for implanted intravenous ports?
<p>Yes, the B. Braun Surecan Safety II Port Access Needle is engineered specifically for <strong>accessing implanted intravenous ports</strong>.</p>

<p>It is designed to ensure safe and reliable high-pressure access, featuring:</p>

<ul>
<li><strong>Power Injection Support:</strong> Non-coring and angled needles are suitable for power injections up to <strong>325 psi</strong>.</li>
<li><strong>Injury Prevention:</strong> Includes a manually activated safety mechanism that deploys upon needle removal, shielding the tip to reduce the risk of needlestick injuries.</li>
<li><strong>Secure Handling:</strong> Designed with flexible, ergonomic wings and a transparent base plate for stable insertion and visualization.</li>
</ul>
How is the safety mechanism deployed and confirmed?
<p>The B. Braun Surecan Safety II features an advanced system that combines manual activation with visual confirmation to help reduce the risk of needlestick injuries. The process is as follows:</p>

<ul>
<li><strong>Activation:</strong> The safety mechanism must be manually activated by the user.</li>
<li><strong>Deployment:</strong> The safety shield automatically deploys upon the <strong>removal of the needle</strong> from the implanted port, instantly covering the sharp tip.</li>
<li><strong>Confirmation:</strong> Successful engagement is confirmed visually. A clear <strong>green dot</strong> becomes visible through the transparent bottom plate, ensuring the user knows the safety device is fully deployed.</li>
</ul>
Can this needle handle high-pressure power injections?
<p>Yes, the B. Braun Surecan Safety II Port Access Needle is specifically engineered to be highly pressure-resistant and reliable during power injections.</p>

<p>It features a non-coring, angled needle design that is suitable for maximum pressures up to <strong>325 psi</strong>, making it fully compatible with high-flow procedures.</p>
How does the safety mechanism deploy?
<p>The Surecan Safety II needle features a manually activated, multi-step safety mechanism designed to prevent needlestick injuries upon removal:</p>

<ul>
<li><strong>Activation and Shielding:</strong> The mechanism is <strong>manually activated</strong> by the clinician and deploys immediately upon the <strong>withdrawal of the needle</strong> from the implanted port, effectively shielding the non-coring tip.</li>
<li><strong>Visual Confirmation:</strong> Successful safety engagement is confirmed by a visible <strong>green dot</strong> indicator that appears through the small, transparent base plate.</li>
<li><strong>Secure Handling:</strong> The assembly includes flexible, ergonomic wings that facilitate <strong>secure handling</strong> throughout the insertion and removal process.</li>
</ul>
What sizes and configurations are offered?
<p>The B. Braun Surecan Safety II Port Access Needles are available in multiple sizes and configurations. All variants feature a non-coring, angled design suitable for <strong>power injections up to 325 psi</strong>.</p>

<p><strong>Available Sizes (Gauge x Length):</strong></p>
<ul>
<li><strong>Gauges:</strong> 19 G, 20 G, and 22 G</li>
<li><strong>Needle Lengths:</strong> Ranging from 0.5 in (12 mm) up to 1.5 in (38 mm)</li>
</ul>

<p><strong>Available Configurations:</strong></p>
<ul>
<li><strong>Needle-Only:</strong> The standard port access needle.</li>
<li><strong>Integrated Option:</strong> Configurations pre-attached with a <strong>Caresite Y Injection Site</strong> (luer access device).</li>
</ul>
How many Surecan Safety II needles are in a case?
<p>Each case of the B. Braun Surecan Safety II Port Access Needles includes <strong>100</strong> port access needles.</p>
Is a Caresite Y Injection Site option available?
<p>Yes, the B. Braun Surecan Safety II Port Access Needle is available in configurations that include a Y-site connection, providing enhanced versatility for access and administration.</p>

<p>When ordering, you can select from two main configurations:</p>

<ul>
<li><strong>Standard Access Needle:</strong> The port access needle supplied without an attached accessory device.</li>
<li><strong>Accessory Configuration:</strong> The needle pre-attached with a <strong>Caresite luer access device</strong>, which includes the integrated Caresite Y Injection Site.</li>
</ul>
What is the typical shelf life for these needles?
<p>The shelf life for the B. Braun Surecan Safety II Port Access Needle depends on the specific variant you order:</p>

<ul>
<li>The typical shelf life for most configurations is <strong>60 months</strong>.</li>
<li>Please note that some specific product variants may have a shorter shelf life of <strong>36 months</strong>.</li>
</ul>