Sale price$4,888.50
Est. Delivery:
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Bovie Bantam PRO A952-G Electrosurgical Generator Package combines the powerful Bantam PRO A952 Electrosurgical Generator with the innovative Smoke Shark II System. This combination creates a smoke-free, odor-free environment that is comfortable for both users and patients.

Warranty: 4 Years. The handpiece is covered for 1 year or 25 autoclave cycles, whichever comes first.

The Bovie Bantam PRO A952-G Electrosurgical Generator Package includes the following:

  • Bovie Bantam PRO A952-G Electrosurgical Generator (#A952):
    • Handpiece (#A902).
    • (2) Disposable Handpiece Sheaths - Non-Sterile (#A910).
    • (2) Disposable Handpiece Sheaths - Sterile (#A910ST).
    • Sterile Disposable Electrodes: (3) #ES01, (1) #ES02, (1) #ES20.
    • Non-Sterile Disposable Dermal Tips: (5) #A804, (5) #A806, (2) #A806DE.
    • Sterile Disposable Dermal Tips: (2) #A805, (2) #A807, (2) #A807DE.
    • (2) Reusable Grounding Cords (#A1252C).
    • (5) Disposable Split Grounding Pads (#ESRE).
    • Wall Mount Kit (#A837).
    • 110 VAC Hospital-grade power cord.
    • User's Guide (#MC-55-238-001).
  • Bovie Smoke Shark II System:
    • Smoke Shark II with Pneumatic Footswitch (FSSEP) (#SE02).
    • 35-Hour Filter (#SF35).
    • 6' Long 7/8" Tube (#786T).
    • Reducer Fitting (attaches to vaginal speculum) (#SERF).
  • ESLK Electrosurgical Loop Kit
    • 10 mm x 10 mm loop (#ES09).
    • 15 mm x 10 mm loop (#ES11).
    • 20 mm x 8 mm loop (#ES12).
    • 20 mm x 15 mm loop (#ES13).
    • 10 mm x 8 mm square (#ES16).
    • (5) Extended Ball Electrodes (#ES07).
  • A812-C Electrosurgical Mobile Stand
    • Mobile Stand (#A812-C).
    • Height Extender (#A812-E).
    • Instrument Tray (#A808-T).
    • Bottom Tray (#A812-BT).

The Bantam PRO A952-G Electrosurgical Generator Package enables users to tackle the toughest skin conditions, while also ensuring that the smoke and odors are removed during the process. The Bantam PRO A952-G Electrosurgical Generator itself is a high frequency desiccator that can remove skin tags, cherry angiomas, and more, through electrosurgical cutting, coagulation, fulguration, and bipolar procedures. The Smoke Shark II ensures that any smoke, toxic plumes, aerosols, or odors produced at the surgical site are taken away.

The A952 Electrosurgical Generator produces up to 50 watts of power for six different modes of electrosurgery. The power can be adjusted in 1/10th increments, to ensure the most accurate output for each case. In addition, there's no grounding pad required when working with the desiccator. The Smoke Shark II contains a filter with up to 35 hours of performance and a monitoring system that lets the user know when it's time to change the filter.

Features

Bovie Bantam PRO A952-G Electrosurgical Generator Package Features

  • Full system comes complete with a mobile stand for portability.
  • A952 Electrosurgical Generator comes with digital error detection for continuous safety monitoring while in use.
  • Smoke Shark II coms ready to use with a filter that lasts 35 hours.
  • Two devices in one efficient package.

Specifications

Bovie Bantam PRO A952-G Electrosurgical Generator Package Specifications

  • Shipping Weight: ~ 20 lb.
  • Bovie Bantam PRO A952-G Electrosurgical Generator:
    • Weight: 5 lb (2.26 kg).
    • Dimensions: 4.13" (L) x 8.98" (W) x 7.4" (H) (10.5 cm x 22.8 cm x 18.8 cm).
    • Output Power Modes:
      • Cut, Blend, Coagulation: 50 watts.
      • Fulguration, Bipolar Micro Bipolar: 40 watts.
    • Output Frequency: 304 - 451 kHz.
    • Line Frequency: 50 Hz.
  • Bovie Smoke Shark II Smoke Evacuator:
    • Weight: 10 lb (4.3 kg).
    • Dimensions: 15.5" (L) x 11" (W) x 6" (H) (39.4 cm x 27.9 cm x 15.2 cm).
    • Line Frequency: 50 - 60 Hz (auto-sensed).
    • LED Display Shows: Filter Status, Flow Rate, Service Required notifications.
    • Noise Level: 55 dBA maximum.

Configurations

Bovie Bantam PRO A952-G Electrosurgical Generator Package Configurations

  • #A952-G: 100 - 120 VAC Smoke Shark II.
  • #A952-220-G: 220 - 240 VAC Smoke Shark II.

Frequently asked questions

What procedures does the Bantam PRO generator support?

The Bovie Bantam PRO A952-G is a highly versatile generator, engineered as a high-frequency desiccator capable of supporting a wide range of electrosurgical procedures. It is particularly effective for dermatological conditions, such as treating localized lesions like skin tags and cherry angiomas.

The generator offers six distinct output modes for maximum surgical flexibility:

  • Cutting (Max 50W)
  • Blending (Max 50W)
  • Coagulation (Max 50W)
  • Fulguration (Max 40W)
  • Bipolar (Max 40W)
  • Micro Bipolar (Max 40W)

Power output is highly precise, adjustable in 1/10th increments. This system is ideal for use in fields like dermatology and gynecology.

How precise are the six electrosurgical output modes?

The Bovie Bantam PRO A952 Generator ensures precise energy delivery with power adjustable in fine 1/10th increments. It offers six distinct electrosurgical modes for versatile procedures, with the following maximum outputs:

Mode Maximum Power Output
Cut 50 watts
Blend 50 watts
Coagulation 50 watts
Fulguration 40 watts
Bipolar 40 watts
Micro Bipolar 40 watts
Is the Bovie generator a complete system?

Yes, the Bovie Bantam PRO A952-G package is a comprehensive, ready-to-use electrosurgical system designed for immediate clinical use.

It is bundled as a complete mobile setup, including:

  • Electrosurgical Generator: The Bantam PRO A952 generator (up to 50 watts).
  • Smoke Evacuation: The integrated Smoke Shark II System for removing toxic plumes and odors.
  • Mobile Stand: The A812-C Mobile Stand with trays for easy portability and organization.
  • Accessories: The package includes the handpiece, sheaths, sterile and non-sterile dermal tips, various electrodes, grounding cords, and the ESLK Electrosurgical Loop Kit.
Does the Bovie Bantam PRO A952 Electrosurgical Generator include grounding pads?

Yes, the Bovie Bantam PRO A952-G Electrosurgical Generator Package includes (5) Disposable Split Grounding Pads (#ESRE), along with two reusable grounding cords, to ensure safe and effective operation.

How long does the Smoke Shark II filter last?

The Smoke Shark II System includes a filter designed for up to 35 hours of use. It also features a monitoring system that indicates when the filter needs to be changed, ensuring consistent performance and a smoke-free environment.

Is the generator configured for standard US voltage?

The Bovie Bantam PRO A952-G Electrosurgical Generator Package is configured for 100 – 120 VAC operation. This configuration is designed for standard US power requirements and includes a 110 VAC hospital-grade power cord.

Is the Smoke Shark II system quiet?

Yes, the Smoke Shark II smoke evacuator operates at a maximum noise level of 55 dBA, contributing to a quiet and comfortable surgical environment for both users and patients.

How portable is the Bantam PRO A952-G Generator?

The Bovie Bantam PRO A952-G Electrosurgical Generator is highly portable, weighing just 5 lb (2.26 kg) and featuring compact dimensions of 4.13” (L) x 8.98” (W) x 7.4” (H) (10.5 cm x 22.8 cm x 18.8 cm). This design ensures easy transport and maneuverability, especially when combined with the included mobile stand.

Is a mobile stand included for portability?

Yes, the Bovie Bantam PRO A952-G Package includes the A812-C Electrosurgical Mobile Stand to ensure the system can be easily moved between locations.

The complete mobile stand assembly includes:

  • The A812-C Mobile Stand base
  • Height Extender (#A812-E)
  • Instrument Tray (#A808-T)
  • Bottom Tray (#A812-BT)
Does the generator have continuous safety monitoring?

The Bovie Bantam PRO A952-G Electrosurgical Generator offers continuous safety monitoring through its digital error detection system.