Regular price$829.00 Sale price$805.00
Est. Delivery: 
<p>Earn%20[points_amount]%20when%20completing%20this%20purchase.</p>

Description

Zoll Pro-Padz Gel Radiolucent Multi-Function Electrodes are designed to provide an unobstructed view of the coronary arteries during x-ray studies. Zoll Pro-Padz are specifically designed, tested, and validated for use with Zoll defibrillators and pacemakers.

Specifications

Zoll Pro-Padz Solid Gel Radiolucent Multi-Function Electrode Specifications4

  • Gel Type: Polymer Hydrogel.
  • Shelf Life: 12 months.
  • Conductive Element: Silver/silver chloride.
  • Packaging: Polyester foil peelbound laminate.
  • Lead Wire Length: 32" (81.3 cm).

Configurations

Zoll Pro-Padz Gel Radiolucent Multi-Function Configurations


Part Number Quantity Gel
#8900-2105-01 12 pairs Liquid
#8900-2106-01 1 pair Liquid
#8900-4005 12 pairs Solid
#8900-4006 1 pair Solid

Literature

Zoll Pro-Padz Gel Radiolucent Multi-Function Electrodes Literature

Zoll Pro-Padz Specification Sheet

Zoll Complete Electrode Product Guide

Frequently asked questions

Are Pro-Padz compatible with Zoll devices?

Yes, the Zoll Pro-Padz Gel Radiolucent Multi-Function Electrodes are explicitly designed and validated for seamless integration and reliable performance with Zoll equipment. They are fully compatible with: * Zoll Defibrillators * Zoll Pacemakers This specific compatibility ensures safety and optimal function in critical medical environments.

What is the guaranteed shelf life of these electrodes?

The shelf life for the Zoll Pro-Padz varies depending on the specific gel formulation you select:

  • Liquid Gel Variants: These electrodes have a guaranteed shelf life of 12 months.
  • Solid Gel Variants: These electrodes provide an extended shelf life of 24 months, which is beneficial for managing inventory.

All products are supplied in Factory New condition.

Are liquid and solid gel pads offered?

Yes, the Zoll Pro-Padz are offered in two distinct gel configurations to meet varied clinical preferences and applications:

  • Liquid Gel (Polymer Hydrogel): Designed to ensure optimal contact and reliable conductivity.
  • Solid Gel: Provides a robust application for secure, dependable electrical contact.

Regardless of the gel type selected, all Pro-Padz feature a crucial radiolucent design. This unique feature allows medical professionals to maintain an unobstructed view of the coronary arteries while the patient undergoes simultaneous x-ray studies. These electrodes are available in packages containing either 1 pair or 12 pairs.

Are these electrodes radiolucent?

Yes, the Zoll Pro-Padz are specifically engineered with a radiolucent design. This is a crucial feature that ensures the electrodes maintain transparency during diagnostic imaging.

This radiolucency provides a significant clinical advantage by allowing for the unobstructed viewing of coronary arteries when the patient is undergoing necessary X-ray or fluoroscopy studies.

Key features of the electrodes include:

  • Tested and validated for exclusive use with Zoll defibrillators and pacemakers.
  • Utilize a reliable Silver/silver chloride conductive element.
  • Available in both Liquid Gel (Polymer Hydrogel) and Solid Gel configurations to suit clinical preference.
What is the primary benefit of the radiolucent design of these electrodes?

The radiolucent design allows for an unobstructed view of coronary arteries during X-ray studies, which is essential in cardiac procedures.

What high-quality conductive material is used?

The Zoll Pro-Padz Gel Electrodes utilize a Silver/silver chloride conductive element. This material is chosen specifically for its excellent conductivity, ensuring reliable and accurate electrical function during defibrillation, pacing, and monitoring procedures.

What is the length of the electrode lead wire?

The lead wire included with the Zoll Pro-Padz electrodes is 32 inches (81.3 cm) long.

What material is used for the packaging?

The Zoll Pro-Padz electrodes are sealed in polyester foil peelbound laminate. This specialized packaging material helps maintain the integrity and sterility of the electrodes before clinical use.

What gel types and quantities are available?

The Zoll Pro-Padz electrodes are offered in configurations that provide flexibility in both gel type and packaging quantity.

Available Configurations:

  • Gel Type: You can choose between Liquid Gel (Polymer Hydrogel) or Solid Gel. Both types feature a high-performance Silver/silver chloride conductive element for reliable contact.
  • Quantity: They are packaged in convenient single 1-pair pouches or bulk 12-pair boxes.

Key Specification Note:
While the general shelf life is 12 months, the 12-pair Solid Gel configuration offers an extended 24-month shelf life. Regardless of the configuration, all electrodes retain their primary feature: a radiolucent design for unobstructed viewing during X-ray procedures.

Are these electrodes factory new?

Yes, Zoll Pro-Padz Gel Radiolucent Multi-Function Electrodes are factory new, ensuring optimal performance and reliability for critical medical procedures.