Sale price$32.74

Special Order Item

Est. Delivery:
<p>Earn%20[points_amount]%20when%20completing%20this%20purchase.</p>

Description

Hillrom . Patented new Axial PointScource Optics. Illumination system converges the light to a point at the cornea, allowing easy entry into small, undilated pupils. The illumination pathway then diverges to the retina, illuminating a very wide area of the fundus. Viewing system enables the operator to view the illuminated area on virtually the same axis, creating the widest field-of-view attainable. Provides a five-times larger view of the fundus than every before achieved with a standard ophthalmoscope in an undilated eye. Increases magnification by 26% over a standard ophthalmoscope. Patented Glare Extinguishment System prevents interference from unwanted glare and reflections. Works with all existing Welch Allyn 3.5v power sources (battery handle or wall transformer) saving additional investment. The patient eyecup establishes and maintains proper viewing distance, provides stabilization for the view, is a pivoting point for leverage in panning around the retina, occludes ambient light, and helps with orientation. The dynamic focusing wheel adjusts the focus in a continuous, smooth action for more precise control and the optimum view with a focusing range of -20 to +20 diopters. The aperture dial has micro, small, and large spot sizes, a slit aperture, and red-free filter, and cobalt blue filter with add-on corneal magnifying lens (Model 11820 only).

Frequently asked questions

Does it offer a larger field of view?

Yes, the iExaminer SmartClip provides a five-times larger view of the fundus compared to a standard ophthalmoscope, specifically in an undilated eye.

How much more magnification does it provide?

This SmartClip delivers a 26% increase in magnification over standard ophthalmoscopes, allowing for more detailed examination.

Is glare reduction effective?

Absolutely. It features a patented Glare Extinguishment System designed to prevent unwanted glare and reflections, ensuring a clearer view.

Is it compatible with my existing power sources?

Yes, it is designed for versatile use with all existing Welch Allyn 3.5v power sources, including battery handles and wall transformers.

What is the purpose of the patient eyecup?

The integrated patient eyecup serves multiple purposes: it establishes and maintains proper viewing distance, stabilizes the view, acts as a pivoting point, occludes ambient light, and aids orientation.

Can I adjust the focus easily?

It includes a dynamic focusing wheel that allows for precise focus control, with a range of -20 to +20 diopters.

What specialized aperture options are included?

The iExaminer SmartClip features a versatile aperture dial that provides several essential options for comprehensive ophthalmic examinations:

  • Micro spot size
  • Small spot size
  • Large spot size
  • Slit aperture
  • Red-free filter
  • Cobalt blue filter

Note that while the cobalt blue filter is included, the add-on corneal magnifying lens intended for use with this filter is compatible only with Model 11820.

How does the illumination system work?

The Welch Allyn iExaminer SmartClip features Axial PointSource Optics for its illumination system. This technology works by:

  • Converging light at the cornea to easily enter even small, undilated pupils.
  • Diverging the light once inside to illuminate a wide area of the fundus.
What is included in the package?

The package contains two iExaminer SmartClips.

What is the product's weight?

Each Welch Allyn iExaminer SmartClip unit weighs 0.02 POUNDS, making it a very lightweight accessory for your ophthalmic instruments.