Description

The Surgimedics 7/8" x 10' Smoke Evacuation Tubing with Integral Wand and Sponge Guard (#905057-000 / 24 per Box) is compatible with all smoke evacuators with a 7/8" port.

Surgimedics offers a wide selection of vacuum hose, medical tubing, adapters, and collection wands for efficient capture of the airborne contaminants and odor found in surgical smoke when used with a smoke evacuator. To maximize flow rates and to minimize noise levels, Surgimedics' corrugated tubing is offered with a smooth bore inner surface. And with a number of adapters and reducers also available, Surgimedics provides optimum flexibility in choosing the right tubing for each laser or electrosurgical procedure.

Using the right tubing size or positioning the tubing in the right location is as critical to efficient smoke evacuation as the smoke evacuator's filter. A filtration system can remove particulate matter or odor from surgical smoke only if it has been captured by the collection device. Every effort, then, should be made to position the tubing as close as possible to the procedure site to maximize the amount of surgical smoke captured. The further a hose or tubing is from the procedure site, the efficiency of the smoke evacuator will decrease significantly, allowing laser plume or surgical smoke to escape into the room.

Specifications

Surgimedics 7/8" x 10' Smoke Evacuation Tubing with Integral Wand and Sponge Guard Specifications

  • Diameter: 7/8".
  • Length: 10 ft.
  • Non-sterile.

Literature

Surgimedics 7/8" x 10' Smoke Evacuation Tubing with Integral Wand and Sponge Guard Literature

CLS-Surgimedics Product Brochure

Frequently asked questions

Is this tubing compatible with all 7/8" port evacuators?

Yes, this Surgimedics smoke evacuation tubing offers broad compatibility and is designed to integrate seamlessly with all smoke evacuator units that utilize a 7/8” port connection.

What are the benefits of the integral wand and sponge guard?

The integral wand and sponge guard are key components designed to optimize the efficiency and ease of use of the smoke evacuation system directly at the surgical site.

Benefits include:

  • Enhanced Source Capture: These integrated components facilitate the precise, close-range collection of laser plume, surgical smoke, and airborne contaminants and odors right at the source. This is crucial for maximizing filtration efficacy, as evacuation efficiency drops significantly the further the tubing is placed from the smoke source.
  • Improved Usability: The integrated design simplifies setup and provides enhanced maneuverability, ensuring the tubing can be optimally positioned during surgical procedures.

This system is essential for effective surgical smoke management by enabling efficient capture where it matters most.

Is the tubing optimized for maximum flow rates?

Yes, the tubing is specifically engineered for optimal performance in smoke evacuation.

It features a unique construction that helps maximize efficiency:

  • Design: The tubing is corrugated on the exterior but incorporates a smooth bore inner surface.
  • Benefit: This smooth interior design is crucial for maximizing suction flow rates and minimizing associated noise levels during operation, ensuring efficient capture of surgical smoke.
How many tubes are included per box?

The tubing is supplied in bulk quantity suitable for continuous use in surgical environments. You will receive 24 units of the Surgimedics 7/8” x 10’ Smoke Evacuation Tubing with Integral Wand and Sponge Guard in each box.

Is the surgical smoke evacuation tubing sterile?

No, the Surgimedics smoke evacuation tubing is non-sterile. It is supplied factory new and packaged in boxes of 24 units.

What are the specific dimensions of the tubing?

The Surgimedics smoke evacuation tubing features the following dimensions:

  • Diameter: 7/8 inches
  • Length: 10 feet

This standard 7/8-inch sizing ensures broad compatibility, allowing it to connect seamlessly with all smoke evacuator units that utilize a 7/8-inch port. Additionally, the tubing is corrugated but includes a smooth bore inner surface designed to maximize suction flow rates and minimize noise during surgical procedures.

What procedures is this tubing used for?

The Surgimedics smoke evacuation tubing is intended for use in surgical environments during electrosurgical or laser procedures.

Its primary function is to efficiently capture airborne contaminants and odors (surgical plume) produced during these procedures, helping to maintain air quality.

For compatibility, this tubing is designed to integrate seamlessly with any smoke evacuator unit that utilizes a 7/8” port connection.

Does the integrated sponge guard enhance collection efficiency?

Yes, the integral sponge guard significantly contributes to the effectiveness of the smoke evacuation process. It is part of the built-in functionality designed for surgical smoke management.

Key benefits include:

  • Enhanced Collection Efficiency: The integrated wand and sponge guard facilitate the precise capture of airborne contaminants and odors directly at the source.
  • Ease of Use: This component provides enhanced ease of use and helps ensure the tubing is optimally positioned at the procedure site to maximize filtration effectiveness.