OEMs & Models > AUTOCLAVES AND STERILIZERS > PELTON & CRANE > Validator 10 (AA) > PCK149

AUTOCLAVES AND STERILIZERS
PELTON & CRANE
Validator 10 (AA)

Tech Support Library

RPI Part #PCK149
OEM Part #(OEM Part # Not Available)

PRESSURE/TEMPERATURE CONVERSION KIT

  • Includes: Steam Sensor Assembly (RPI Part #PCS100), Pressure/Temperature Board (RPI Part #PCB098), and Pressure Tube Kit (RPI Part #RPK282)
  • RPI Steam Sensor (RPI Part #PCS100) can only be used with RPI Pressure/Temperature Board (RPI Part #PCB098)

Fits: PCB mounts on pressure/temperature module bracket and sensor connects to lower back of chamber or tee block and plugs into PCB

Frequently asked questions

Does this kit provide a comprehensive conversion solution?

Yes, the RPI PCK149 is a complete kit designed to fully update or replace your pressure and temperature monitoring system. It includes:

  • Steam Sensor Assembly (PCS100)
  • Pressure/Temperature Board (PCB098)
  • Pressure Tube Kit (RPK282)
Is this kit specifically engineered for Pelton & Crane units?

Absolutely. This kit is specifically designed for the PELTON & CRANE Validator 10 (AA) autoclave and sterilizer, ensuring precise compatibility and reliable performance.

Are there specific component requirements for this system?

Yes, for optimal system integrity, it is crucial to note that the RPI Steam Sensor (PCS100) must be used in conjunction with the included RPI Pressure/Temperature Board (PCB098). The kit is engineered to function as an interdependent assembly.

Is the equipment supplied in new condition?

Yes, all components in the PCK149 kit are supplied in Factory New condition, ensuring the highest level of reliability for your critical medical sterilization equipment.

How is the PCB installed in the unit?

Installation is straightforward: the Pressure/Temperature Board (PCB098) is designed to mount directly onto the existing pressure/temperature module bracket within your sterilization unit.

Where does the steam sensor connect within the autoclave?

The steam sensor is designed to connect to the lower back of the sterilization chamber or the tee block, and it plugs directly into the provided Pressure/Temperature Board for seamless integration.

Does this kit help maintain sterilization accuracy?

Yes, this conversion kit is essential for ensuring both regulatory compliance and high accuracy in pressure and temperature readings during your sterilization cycles.

Is this a suitable kit for overhaul operations?

It is ideal for maintenance, repair, and overhaul (MRO) operations. Providing a complete assembly, it simplifies the process of restoring or upgrading the monitoring functionalities of the Validator 10 (AA) model.

How long should I expect for order processing?

This item is shipped directly from the manufacturer with an estimated lead time of 1 to 2 weeks (approximately 7 days).

Is technical support available if I have installation questions?

Yes, RPI provides dedicated customer support. If you have questions regarding the installation or specific technical requirements, you can reach out for assistance at (800) 221-9723.