Sale price$148.82
Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Rhythmlink Disposable Parallel Pair Stimulating Sticky Pad EMG Surface Electrodes are versatile, robust pads that feature an aggressive hydrogel which keeps the electrodes in place and enhances physiologic stimulations.

Warranty: Until Use or Expiration.

Specifically constructed for stimulating, Rhythmlink's stimulating electrodes minimize burn risk during stimulation. These self-adhesive EMG electrodes are 100% disposable, and the only on the market designed just for stimulation.

Quantity: Two pairs (four electrodes) per pouch.

Features

Rhythmlink Disposable Parallel Pair Stimulating Sticky Pad EMG Surface Electrodes Features

  • Innovative leadwire glue enables custom separation - as little or as much as needed.
  • Stimulating pads feature a specially formulated stimulating hydrogel that minimizes stimulation risks.
  • Identifying letters distinguish between pads.
  • Molded safety connectors with ample built-in strain relief.

Specifications

Rhythmlink Disposable Parallel Pair Stimulating Sticky Pad EMG Surface Electrodes Specifications

  • Materials:
    • Pad: Conductive vinyl layer coated with cotton micropore.
    • Pad Backing: Mylar.
    • Stimulating Hydrogel: AG702 stimulating.
    • Leadwire: Tinned copper with PVC jacket.
    • Leadwire Pairing: Chemically bonded.
    • Connector: DIN 42 802.
    • Sterilized: No.
  • Environment:
    • Latex-free electrode.
    • PVC-free packaging.
  • Packaging:
    • Pouch: Metallized foil.
    • Pouch Size: 130 mm x 150 mm.
    • Box: Cardboard.

Configurations

Rhythmlink Disposable Parallel Pair Stimulating Sticky Pad EMG Surface Electrodes Configurations

Product Number Pad Size Lead Length Quantity Weight (Box)
#PSTCUS30026 Small (15 mm x 20 mm) 3.0 m 20 Pairs -
#PSTCUS15026 Small (15 mm x 20 mm) 1.5 m 40 Pairs 1.45 lb
#PSTCUS25026 Small (15 mm x 20 mm) 2.5 m 40 Pairs 2.05 lb
#PSTCUL15026 Large (20 mm x 25 mm) 1.5 m 40 Pairs 1.5 lb
#PSTCUL25026 Large (20 mm x 25 mm) 2.5 m 40 Pairs 2.11 lb
Colors: Black/Red and Blue/Green

Literature

Rhythmlink Disposable Parallel Pair Stimulating Sticky Pad EMG Surface Electrodes Literature

Rhythmlink Disposable Sticky Pad Surface Electrode Instructions

Rhythmlink Disposable Paired Sticky Pad Surface Electrode Datasheet

Frequently asked questions

Is the AG702 hydrogel engineered to minimize burn risk?

Yes, the Rhythmlink electrodes utilize a specialized, safety-focused design for stimulation applications:

  • Stimulating Hydrogel: They feature the AG702 stimulating hydrogel, which is specifically engineered to enhance physiological stimulations while actively minimizing the risk of burns.
  • Secure and Stable Contact: The aggressive hydrogel ensures superior adhesion, keeping the electrodes firmly in place throughout the procedure, which is crucial for reliable and safe stimulation delivery.

These disposable sticky pads are exclusively intended for physiological stimulating applications.

Is the leadwire separation distance adjustable?

Yes, the leadwire separation distance is fully customizable.

These electrodes feature an innovative leadwire glue that allows users to adjust the separation between the parallel leadwires, providing crucial flexibility in managing your setup. This feature is designed to help you:

  • Customize the configuration for specific stimulation protocols.
  • Tailor the distance to suit various patient or instrument arrangements.
Are high-quality materials used?

The Rhythmlink electrodes are constructed using specialized components designed for enhanced safety and reliable physiological stimulation:

  • Safety Hydrogel: They feature an aggressive AG702 stimulating hydrogel. This unique, specially formulated adhesive ensures superior adhesion for secure placement while actively minimizing the risk of patient burns during stimulation procedures.
  • Pad Construction: The pad consists of a conductive vinyl layer coated with cotton micropore, backed by durable Mylar.
  • Leadwires and Connectors: The robust leadwires are made of tinned copper with a PVC jacket, terminating in molded DIN 42 802 safety connectors. These connectors also include built-in strain relief for longevity.
  • User Safety: The entire assembly is latex-free, and the packaging material (metallized foil pouch and cardboard box) is PVC-free.
Are these electrodes latex-free?

Yes, the Rhythmlink Disposable Parallel Pair Stimulating Sticky Pad EMG Surface Electrodes are latex-free, making them suitable for use with patients who have latex allergies.

How many electrodes are included in each pouch?

Each pouch contains two pairs (four electrodes).

Are these electrodes optimized for physiologic stimulation?

Yes, these Rhythmlink electrodes are optimized exclusively for physiologic stimulation applications. They are reportedly the only self-adhesive EMG electrodes on the market specifically tailored for this purpose, which helps maximize performance and safety.

Key features ensuring reliable and safe stimulation include:

  • Minimized Risk: They utilize a specially formulated AG702 stimulating hydrogel designed to significantly mitigate the risk of burns and irritation during electrical stimulation protocols.
  • Superior Adhesion: An aggressive hydrogel compound ensures the electrodes remain securely in place, guaranteeing stable contact and consistent signal delivery.
  • Customizable Leadwires: The innovative leadwire glue allows users to safely separate and adjust the parallel leadwires to the exact distance needed for custom setups.
  • Quality Connection: They feature molded DIN 42 802 safety connectors with built-in strain relief.
What sizes and lead lengths are offered?

These disposable stimulating electrodes are available in two different pad sizes and multiple lead wire lengths to accommodate various clinical and diagnostic needs:

  • Small Pad: 15 mm x 20 mm
  • Large Pad: 20 mm x 25 mm

Available Lead Lengths:

  • 1.5 m
  • 2.5 m
  • 3.0 m (Available for small pad sizes)

Each pair is equipped with durable, color-coded leadwires designed for secure connectivity and ease of identification during setup.

How do identifying letters help with pad placement?

The electrodes are clearly distinguished by identifying letters printed on the pads.

This feature helps users easily differentiate between the parallel pairs, ensuring proper configuration and ease of setup during physiologic stimulation protocols.