Does this sensor offer broad ventilator compatibility?
Yes, the Maxtec MAX-16 Oxygen Cell is an essential FiO2 (Fraction of Inspired Oxygen) Sensor designed for broad compatibility with many critical respiratory support systems. It can be used as a direct replacement component for various ventilators from major manufacturers, including:
- Carefusion: SIPAP and Avea models
- Maquet: Servo 300 and 900 models
- Covidien: Models 740, 760, 840, and the PB2000 Tester
- Versamed: iVent 201
This product is available in two configurations: the original Maxtec branded sensor (R114P70) or a reliable, equivalent cell (G0-160) manufactured by Cables and Sensors.
Are two high-quality configurations available?
Yes, the Maxtec MAX-16 O₂ Cell is available in two distinct, factory-new configurations to suit different performance and longevity requirements. Both function as FiO2 (Fraction of Inspired Oxygen) Sensors for medical ventilators.
1. Original Maxtec Brand (MPN: R114P70)
- Shelf Life/Warranty: 18 Months
- Response Time: ≤ 30 seconds
- Output Range: 8.5 to 15.0 mV
- Linearity: Maximum ± 1% full scale error
2. Equivalent by Cables and Sensors (MPN: G0-160)
- Shelf Life/Warranty: 16 Months
- Faster Response Time: Less than 12 seconds
- Connector Type: 3-Pin Molex
What is the shelf life for each configuration option?
The shelf life of the oxygen cell depends on the configuration you choose, as this is tied to the manufacturer:
- Maxtec Original Brand (MPN: R114P70): Provides an 18-month shelf life.
- Cables and Sensors Equivalent (MPN: G0-160): Provides a 16-month shelf life.
What is the output range of the Maxtec R114P70 cell?
The original Maxtec MAX-16 Oxygen Cell (R114P70) provides a specific electrical output range:
- Output Range: 8.5 to 15.0 mV
- Linearity: The sensor maintains high accuracy with linearity rated at only ± 1% full scale error maximum.
What is the linearity specification for the original Maxtec oxygen cell?
The linearity specification for the original Maxtec R114P70 unit is ± 1% full scale error maximum.
What connector does the G0-160 equivalent cell use?
The Maxtec equivalent MAX-16 O₂ Cell, manufactured by Cables and Sensors (SKU CAS-G0-160), is equipped with a 3-Pin Molex connector.
Which OEM sensors is the MAX-16 equivalent to?
The MAX-16 Oxygen Cell is designed for broad interchangeability, functioning as a direct replacement for several established industry-standard sensors. It simplifies maintenance by offering high compatibility with various respiratory systems and equipment from major manufacturers.
This sensor is equivalent to the following part numbers:
- Analytical Industries: PSR-11-917M
- Covidien: 10097559
It also functions as a direct equivalent to sensors from other manufacturers, including Puritan Bennett.
Is this O2 cell highly accurate for ventilator FiO2 monitoring?
Yes, the Maxtec MAX-16 Oxygen Cell is an FiO2 (Fraction of Inspired Oxygen) Sensor designed specifically for accurate monitoring within a wide range of medical ventilators (including models from Carefusion, Maquet, and Covidien).
This factory-new cell ensures precise oxygen concentration readings, which is critical for patient safety and maintaining the operational integrity of the life support machinery.
For the highest precision:
- The Original Maxtec R114P70 unit provides detailed performance metrics, including a linearity specification of $\pm$ 1% full scale error maximum and an output range of 8.5 to 15.0 mV.
- The G0-160 Compatible Equivalent also offers reliable measurement with a fast response time of under 12 seconds.
Does this oxygen cell have wide ventilator compatibility?
Yes, the MAX-16 Oxygen Cell is designed to serve as an essential FiO2 sensor replacement component for a broad range of medical ventilators.
It is compatible with systems from leading manufacturers, including:
- Carefusion (SIPAP, Avea)
- Maquet (Servo 300, 900)
- Covidien (740, 760, 840)
- Versamed (iVent 201)
This sensor is intended to integrate seamlessly as a direct replacement component for these specified OEM ventilator systems.
Does the FiO2 sensor provide precise readings?
Yes, the MAX-16 Oxygen Cell is engineered for reliable and precise FiO2 (Fraction of Inspired Oxygen) monitoring, which is critical for ventilator applications. Performance specifications vary based on the configuration selected:
1. Maxtec Original Brand (R114P70)
This option is designed for stability and high precision:
- Precision (Linearity): Guarantees a linearity of ± 1% full scale error maximum.
- Output Range: Rated output is 8.5 to 15.0 mV.
- Shelf Life: Offers a superior 18-month shelf life.
- Response Time: Detects oxygen concentration changes in ≤ 30 seconds.
2. Cables and Sensors Equivalent (G0-160)
This equivalent option is noted for speed:
- Response Time: Significantly faster, responding in < 12 seconds.
- Connectivity: Utilizes a 3-Pin Molex connector.
- Shelf Life: Provides a 16-month shelf life.
Both configurations are Factory New and are compatible with a wide array of systems, including ventilators from Carefusion, Maquet, Covidien, and Versamed.