2+ In Stock

Estimated Delivery: 
<p>Earn%20[points_amount]%20when%20completing%20this%20purchase.</p>

Description

The Masimo LNCS Reusable SpO2 Sensor is comfortable, durable, and reliable. The integrated cable means that the sensor is even simpler to set up and offers improved moisture resistance over sensors with the connector at the monitoring site. It is compatible with all Masimo SET/Nellcor DB9 9-pin connectors.

Warranty: 6 Months From First Use, Within 8 Months of Shipment.

Features

Masimo LNCS Reusable SpO2 Sensor Features

  • LNCS (Low Noise Cabled Sensor).
  • Three foot cable.
  • Easy to move and reapply.
  • Long-lasting sensor.
  • Recessed detector and flexible side flaps reduces ambient light interference.
  • EM resistant.
  • Integrated cable offers increased moisture resistance.
  • Provides accurate readings even during low perfusion and patient movement.
  • Compatible with all Masimo SET Oximeters.

Configurations

Masimo LNCS Reusable SpO2 Sensor Configurations

  • #1863: DC-I (Adult).
  • #1895: TC-I (Tip-Clip EAR).
  • #1896: TF-I (Forehead).
  • #2258: Y-I (Multisite).
  • #2653: DB-I (Adult Soft).

Frequently asked questions

Does the sensor maintain accuracy during movement?

Yes, the Masimo LNCS Reusable SpO2 Sensor is engineered for high performance and reliability. It is designed to provide accurate oxygen saturation (SpO2) readings even under challenging monitoring conditions, including:

  • Patient movement
  • Low perfusion (reduced blood flow)

This ensures consistent and dependable data collection in active clinical environments.

Is the sensor effective during low perfusion?

Yes, the Masimo LNCS Reusable SpO2 Sensor is designed to deliver accurate SpO2 readings even during periods of low perfusion and patient movement, ensuring reliable data when it matters most.

Is this reusable sensor designed for durability?

Yes, the Masimo LNCS Reusable SpO2 Sensor is engineered for exceptional durability and consistent performance in demanding clinical settings. Its robust design features include:

  • Integrated Cable Construction: The hardwired, three-foot cable significantly enhances moisture resistance, providing better protection than sensors that rely on patient-site connectors.
  • Interference Mitigation: It utilizes a recessed detector protected by flexible side flaps to shield against ambient light, ensuring reliable signal integrity.
  • EM Resistance: The sensor is built to be electromagnetic (EM) resistant, allowing it to maintain accurate pulse oximetry readings even in busy environments filled with electronic noise.
  • Reliable Performance: Featuring proprietary LNCS technology, this sensor remains precise even during challenging patient conditions, such as movement or low perfusion.
Does the integrated cable improve moisture resistance?

Yes, the integrated cable design is a key feature of the Masimo LNCS Reusable SpO2 Sensor, enhancing both durability and reliability.

Integrating the three-foot cable directly into the sensor provides two main benefits:

  • Increased Moisture Resistance: This design eliminates a common connection point near the monitoring site, significantly increasing resistance to moisture ingress.
  • Simplified Setup: The streamlined architecture makes the sensor easier to apply and connect to the Masimo SET/Nellcor DB9 9-pin monitoring system.
What sensor configurations are available?

The Masimo LNCS Reusable SpO2 Sensor is available in multiple application-specific configurations to ensure accurate and reliable monitoring across various patient needs and anatomical sites. This allows for optimal placement whether the patient is experiencing motion or low perfusion.

Available configurations include:

  • DC-I (Adult): The standard durable clip configuration for general adult monitoring.
  • TC-I (Tip-Clip EAR): Specifically designed as an ear clip sensor for alternative site monitoring.
  • TF-I (Forehead): Optimized for placement on the forehead.
  • Y-I (Multisite): A versatile configuration suitable for different monitoring locations.
  • DB-I (Adult Soft): A soft probe intended for comfortable adult use.
Does the LNCS sensor minimize ambient light interference?

Yes, the Masimo LNCS Reusable SpO2 Sensor is specifically engineered to minimize interference from ambient light sources.

It achieves this through two key design features:

  • A recessed detector
  • Flexible side flaps

These elements work together to shield the measurement site, ensuring the sensor provides reliable and accurate readings, even in brightly lit clinical environments.

Is the SpO2 sensor EM resistant?

Yes, the Masimo LNCS Reusable SpO2 Sensor is designed to be EM resistant, ensuring reliable performance even in environments with electromagnetic interference.

Does this sensor ensure reliable SpO2 accuracy?

Yes, the Masimo LNCS Reusable SpO2 Sensor is engineered for consistent, professional-grade monitoring even in challenging clinical conditions. Its design specifically focuses on maintaining signal integrity and accuracy through the following features:

  • LNCS Technology: Specifically designed to provide accurate pulse oximetry readings during difficult scenarios, such as patient movement or low perfusion.
  • Advanced Interference Mitigation: The sensor housing utilizes a recessed detector protected by flexible side flaps, which effectively blocks out ambient light that can disrupt readings. It is also designed to be resistant to electromagnetic (EM) interference.
  • Robust Construction: The integrated three-foot cable design enhances durability and offers superior moisture resistance, helping to maintain a reliable connection compared to sensors with exposed connectors at the patient site.
What is the cable length for this sensor?

The sensor features a three-foot integrated cable, simplifying setup and enhancing moisture resistance compared to designs with separate connectors.

Does this sensor offer broad system compatibility?

Yes, the Masimo LNCS Reusable SpO2 Sensor is engineered for seamless integration across a wide range of clinical environments. It features a standard DB9 9-pin connector and is fully compatible with:

  • All Masimo SET Oximeters
  • Monitoring systems utilizing Nellcor-compatible DB9 9-pin connections

This high level of compatibility makes it an efficient and versatile solution for facilities using mixed monitoring equipment.

  • 5 stars: 1 (100%)
  • 4 stars: 0 (0%)
  • 3 stars: 0 (0%)
  • 2 stars: 0 (0%)
  • 1 star: 0 (0%)
W
Walter M.
Love

Love it

Hi Walter, we're thrilled to hear you love the Masimo LNCS Reusable SpO2 Sensor! Thanks for sharing your positive experience.

D
Diana B.

Is this sensor compatible with a Masimo Rad-97 Rainbow Pulse Oximeter?

MFI Medical

Hi Diana,

Thank you for your inquiry.

The Masimo LNCS Reusable SpO2 Sensor is designed for compatibility with all Masimo SET Oximeters. While it is generally compatible with the Masimo SET technology used in the Rad-97 series, we recommend verifying the specific cable requirements for your Rad-97 Rainbow Pulse Oximeter to ensure a proper connection.

For the most accurate technical specifications regarding this compatibility, we recommend consulting the manufacturer directly. You can reach Masimo support at (800) 326-4890. Please provide them with the following part numbers for reference:

Masimo LNCS Reusable SpO2 Sensor (Adult DC-I): MSO-1863
Masimo Rad-97 Pulse CO-Oximeter: MSO-9738
You can view the product details and available configurations on our website here:

Masimo LNCS Reusable SpO2 Sensor: https://mfimedical.com/products/masimo-lncs-reusable-spo2-sensor
Masimo Rad-97 Pulse CO-Oximeter: https://mfimedical.com/products/masimo-rad-97-pulse-co-oximeter

Let us know if you have any additional questions.

B
Brad W.

Will this fit a zoll x?

MFI Medical

Hello Bradley Wing,

The Masimo LNCS Reusable SpO2 Sensor is designed to work with patient monitors that use Masimo SET technology. This includes many Zoll models, however, compatibility can vary depending on the specific device and its configuration.

I recommend reaching out to Masimo or Zoll directly to confirm compatibility before making your purchase.

It's important to ensure compatibility when purchasing medical device accessories and sensors, as using incompatible devices can result in inaccurate readings or potential damage to the equipment.

Thank you for reaching out, and please let me know if you have further questions.

Best regards,
MFI Medical

N
Neil S.

What is this device for?

MFI Medical

Hello Neil,

The Masimo LNCS Reusable SpO2 Sensor is a Low Noise Cabled Sensor that measures SpO2. It is used with devices that measure a patient’s oxygen saturation, such as a pulse oximeter, and is compatible with all Masimo SET/Nellcor DB9 9-pin connectors.

We’re here if you have any other questions!