The CPAC RapidHeat RH-Pro11 HVHA Sterilizer includes four removable instrument trays, one pair of tray removal safety gloves, instructions & care card, and the user manual.

Warranty: 3 Years - Parts and Labor.

An advancement in "RapidCycle" sterilization, the CPAC RapidHeat RH-Pro11 HVHA Sterilizer is a proven method of raising sterilization efficiency. Thanks to state-of-the-art High-Velocity Hot Air (HVHA) technology, the RH-Pro11 provides the fastest instrument turnaround time of any FDA-cleared sterilization technology on the market today. Plus, no steam or water means no prolonged drying cycle and helps ensure a longer product life free of corrosion.

With four removable trays, the RH-Pro11 chamber can be easily modified to handle all sizes of instrument sets.

Features

CPAC RapidHeat RH-Pro11 HVHA Sterilizer Features

  • Accommodates both small and large cassettes.
  • Waterless sterilization with no chemicals.
  • Uses 85% less energy than steam.
  • Documents cycles for easy log retrieval.
  • Self-locking door ensures cycle completion.
  • Up to six large instrument trays per cycle.
  • Large table-top capacity (2295 cubic inches).
  • Non-corrosive sterilizer environment.
  • FDA-cleared six minute cycles (unwrapped).
  • FDA-cleared 12 minute cycles (wrapped).
  • Validate and verify 12-log kill sterilization.
  • Choice of three low-temperature cycles.

Specifications

CPAC RapidHeat RH-Pro11 HVHA Sterilizer Specifications

  • Weight: 90 lb (41 kg).
  • Dimensions: 22.5" (D) x 22.5" (W) x 19.5" (H) (572 mm x 572 mm x 495 mm).
  • Chamber Dimensions: 17.75" (D) x 11" (W) x 11.75" (H) (433 mm x 279 mm x 299 mm).
  • Chamber Capacity: 2294 cubic inches (10 gal / 38 L).
  • Instrument Tray: 15" (D) x 9" (W) x 1" (H) (381 mm x 229 mm x 28 mm).
  • Sterilization Temperature: 375 degrees F (190 degrees C).
  • Sterilization Times:
    • Cycle 1: Six minutes for unwrapped instruments.
    • Cycle 2: Eight minutes for hand pieces and medical drills.
    • Cycle 3: 12 minutes for wrapped instruments.
  • Low Temperature Sterilization Times:
    • 320 degrees F: 42 minute cycle.
    • 300 degrees F: 58 minute cycle.
    • 280 degrees F: 126 minute cycle.
  • N95 FFR Mask Decontamination (175 degrees F): 30 minute cycle.
  • Wrapped Cassettes:
    • 5.5" x 8" x 1.5": 8 Cassettes (Total: 64 Instruments).
    • 6" x 8" x 1.5": No 2-Tier Cassettes.
    • 8" x 11" x 1.5": 4 Cassettes (Total: 80 Instruments).
  • Instrument Capacity:
    • Unwrapped: 3.2 kg; 160 Dental Instruments.
    • Handpieces (Unwrapped): 24 Handpieces; 6 per Tray.
    • Wrapped Instruments: 3.2 kg; 8 Dental Instruments/Pouch; 5 Pouches/Tray; 4 Trays/Load. Total Instruments/Load: 160.
  • Electrical:
    • 110 - 120 V, 60 Hz, 1400 Watts warm up, 300 Watts operating.
    • 220 - 240 V, 50 Hz, 1400 Watts warm up, 300 Watts operating.
  • Safety: Meets requirements of U.S. Electrical Safety Standards.
  • Shipping Weight: 109 lb (49 kg).

Voltages

CPAC RapidHeat RH-Pro11 HVHA Sterilizer Voltages

  • #RH-Pro11: 110 - 120 V.
  • #RH-Pro11-230V: 220 - 240 V.

Accessories

CPAC RapidHeat RH-Pro11 HVHA Sterilizer Accessories

The following accessories are compatible and commonly purchased with the RapidHeat RH-Pro11 HVHA Sterilizer:

  • #400597B: SteriSURE Dry Heat Sterilizer Bags.
  • SteriDent Spore Test Monitoring Service - Dry Heat or Steam:
    • #400633: Box of 12.
    • #400634: Box of 52.
  • #400635: Dry Heat Indicator Strips 4".
  • Self-Seal Nylon Pouches:
    • #400636: 2" x 10".
    • #400651: 3" x 10".
    • #400637: 4" x 10".
    • #400638: 7" x 10.5".
    • #400639: 9.5" x 13".
  • #400640: In-Office Biological Monitoring System.
  • Spore Culture Refill:
    • #400644: Box of 20.
    • #400645: Box of 100.

Frequently asked questions

What are the fastest sterilization cycles?

The CPAC RapidHeat RH-Pro11 offers some of the fastest FDA-cleared sterilization cycles using High-Velocity Hot Air (HVHA) technology at 375°F (190°C):

  • Unwrapped Instruments: 6 minutes
  • Wrapped Instruments: 12 minutes

This waterless, chemical-free method enhances instrument longevity by preventing corrosion.

Can this sterilizer be used to decontaminate N95 masks?

Yes, in addition to the standard sterilization cycles, there is a dedicated cycle for N95 FFR mask decontamination that runs at 175 degrees F for 30 minutes.

What components are included with the sterilizer?

The CPAC RapidHeat RH-Pro11 HVHA Sterilizer is shipped complete with essential items for immediate and safe operation:

  • Four Removable Instrument Trays: These trays (15” x 9” x 1” each) help you maximize the large 2294 cubic inch chamber capacity, allowing the accommodation of various instrument sets and cassettes.
  • One Pair of Tray Removal Safety Gloves: Necessary for safely handling the hot trays after high-temperature sterilization cycles.
  • Instructions & Care Card
  • User Manual
What are the sterilizer's dimensions?

The CPAC RapidHeat RH-Pro11 HVHA Sterilizer features a spacious and flexible design to accommodate various instrument loads.

  • Chamber Dimensions (D x W x H): 17.75” x 11” x 11.75” (433 mm x 279 mm x 299 mm)
  • Exterior Dimensions (D x W x H): 22.5” x 22.5” x 19.5” (572 mm x 572 mm x 495 mm)

The internal chamber provides 2294 cubic inches (approximately 38 liters or 10 gallons) of usable space. It comes with four removable instrument trays, each measuring 15” (D) x 9” (W) x 1” (H), and can hold up to six large instrument trays per cycle.

What are the sterilization cycle durations?

The CPAC RapidHeat RH-Pro11 HVHA Sterilizer offers a range of efficient sterilization cycles:

  • High-Temperature Cycles (375°F / 190°C):
    • Unwrapped Instruments: 6 minutes
    • Hand pieces/Drills: 8 minutes
    • Wrapped Instruments: 12 minutes
  • Low-Temperature Cycles:
    • 320°F: 42 minutes
    • 300°F: 58 minutes
    • 280°F: 126 minutes

Additionally, there is a 30-minute cycle at 175°F specifically for N95 FFR Mask Decontamination. This unit utilizes High-Velocity Hot Air (HVHA), which is a waterless method, preventing instrument corrosion and extending their lifespan.

Does the sterilizer use waterless technology?

Yes, the CPAC RapidHeat RH-Pro11 is a completely waterless sterilization system. It utilizes High-Velocity Hot Air (HVHA) technology instead of steam or water, which offers significant advantages for instrument care.

Key benefits of this waterless system include:

  • Non-Corrosive: Eliminating moisture and chemicals creates a non-corrosive environment that prevents instrument corrosion and prolongs their functional life.
  • Efficiency: It requires no drying time and allows for the fastest FDA-cleared turnaround times (as fast as six minutes for unwrapped instruments).
  • Energy Savings: The HVHA technology also makes the unit highly energy efficient, using 85% less energy than steam sterilizers.
What are the voltage and energy needs?

The CPAC RapidHeat RH-Pro11 HVHA Sterilizer is highly energy efficient, using 85% less energy than steam sterilizers. It has two electrical configurations:

Requirement 110-120 V Model 220-240 V Model
Voltage/Frequency 110 - 120 V, 60 Hz 220 - 240 V, 50 Hz
Warm-up Power 1400 Watts 1400 Watts
Operating Power 300 Watts 300 Watts

This sterilizer also meets U.S. Electrical Safety Standards.

Who is the ideal customer for this sterilizer?

The CPAC RapidHeat RH-Pro11 HVHA Sterilizer is an ideal solution for a range of professional environments due to its efficiency and advanced features:

  • High-Volume Clinical Environments: It’s perfect for settings that require rapid instrument turnaround.
  • Dental Offices: Enhances infection control and efficiency for dental practices.
  • Microsurgical Centers: Provides precise and quick sterilization, crucial for delicate instruments.

This sterilizer is designed for those prioritizing fast, waterless, and non-corrosive sterilization cycles to optimize instrument readiness and extend product life.

Is the sterilizer highly energy efficient?

The sterilizer is exceptionally energy efficient due to its High-Velocity Hot Air (HVHA) technology. Because this unit uses a waterless sterilization method, it eliminates the high energy consumption associated with generating steam and prolonged drying cycles. In fact, the RH-Pro11 uses 85% less energy compared to conventional steam sterilization methods.

What are the temperature settings for sterilization?

The sterilizer operates at a high temperature of 375 degrees F (190 degrees C) for rapid cycles. It also offers lower temperature sterilization options at 320 degrees F, 300 degrees F, and 280 degrees F for specific needs, and 175 degrees F for N95 mask decontamination.

  • 5 stars: 1 (100%)
  • 4 stars: 0 (0%)
  • 3 stars: 0 (0%)
  • 2 stars: 0 (0%)
  • 1 star: 0 (0%)
R
Robert D.
A honest review so far.

The product I received seems to be of good quality. I had thought I was ordering the N95 sterilizer because I was on that website. I received the Pro11 instead. The Pro11 did come in as promised just the wrong machine. I have tried multiple times to contact customer service. Only the initial person was helpful. I was referred up the chain and have not heard back from anyone. . Our office is relying on the N95 for our masks and safety.. Our health is counting on this machine and I was hoping for a quick turn around. I think customer service is critical in business. I spent good money on a machine I did not get. Once this is resolved I can give a better review. Thank you

N
Norbert T.

What does the fda require for validation to use this unit commercially?
We make small medical silicone devices to ship to hospitals sterile and this size is perfect . If the validation info is available and not too onerous we are ready to order. Urgent

MFI Medical

Hello Norbert,

Thank you for your inquiry about the CPAC RapidHeat RH-Pro11 HVHA Sterilizer. We understand that you need information regarding FDA validation requirements for commercial use of this unit.

To use the CPAC RapidHeat RH-Pro11 HVHA Sterilizer for commercial purposes, the FDA requires validation testing to ensure that the unit can consistently achieve sterilization in accordance with FDA guidelines. Validation testing typically involves running a series of test cycles using biological indicators to demonstrate that the unit is capable of achieving sterilization under a variety of conditions.

To obtain specific information on validation requirements and procedures for commercial use of the CPAC RapidHeat RH-Pro11 HVHA Sterilizer, we recommend contacting CPAC directly or consulting with a qualified healthcare professional or regulatory specialist who can provide guidance on FDA validation requirements.

If you have any additional questions or concerns, please don't hesitate to reach out to us. We're here to help you find the best solution for your needs.

Best regards,
MFI Medical

C
Christy R.

con we sterilize our handpieces is this Rapidheat Pro11 Sterilizer?

MFI Medical

Hello Christy,

If your handpiece is autoclavable, the RapidHeat RH-Pro11 HVHA Sterilizer will sterilize it!

We recommend checking the manufacturer recommendations for the handpiece you want to sterilize. The maker of the handpiece will be able to tell you if it can be autoclaved.

The RapidHeat RH-Pro11 HVHA Sterilizer can sterilize; wrapped/unwrapped instruments, handpieces, medical drills, and pouches.

We're here if you have any other questions!