Description

B. Braun Standard Manifolds are specially designed to maximize fluid flow control. Using two or three port normally closed valves, B. Braun's innovative manifolds provide unmatched fluid and drug delivery efficiency in the operating room.

Features

B. Braun Standard Manifolds Features

  • Backcheck valves in each port.
  • Not made with DEHP or natural rubber latex.

B. Braun Standard Manifolds - Anesthesia Tri-Connector with Normally Closed Valves:

  • Two normally closed valves - for injection only.
  • Priming Volume: 1.2 mL.

B. Braun Standard Manifolds - Anesthesia Triple Valve Manifold with In-Line Check Valve:

  • Features in-line check valve and three normally closed low profile valves, which are for injection only.
  • Priming Volume: 2.0 mL.

Specifications

B. Braun Standard Manifolds Specifications

SKU
Priming Volume
Latex Information
Total Shelf Life
Ordering Unit
Units per Case
Dimensions per Case
Shipping Weight per Case
Sterile
#472026 1.2 mL Not made with natural rubber 60 Months Case 50 10.950 x 9.950 x 8.890 inches 1.764 lb Yes
#472090 2.0 mL Not made with natural rubber 60 Months Case 100 14.070 x 12.700 x 14.640 inches 6.001 lb Yes

Configurations

B. Braun Standard Manifolds Configurations

  • #472026: Anesthesia Tri-Connector with Normally Closed Valves.
  • #472090: Anesthesia Triple Valve Manifold with In-Line Check Valve.

Frequently asked questions

Are these manifolds free of DEHP and natural rubber latex?

Yes, patient safety is a key priority for the B. Braun Standard Manifolds. They are explicitly manufactured without common materials of concern, making them suitable for use in sensitive clinical environments.

These sterile manifolds are formulated to exclude:

  • DEHP (a plasticizer).
  • Natural rubber latex, which helps minimize the risk of allergic reactions.
Are these manifolds supplied sterile?

Yes, B. Braun Standard Manifolds are supplied sterile for immediate use in critical environments.

They are provided in Factory New condition, which ensures they are safe and ready for efficient fluid and drug delivery in settings like the operating room.

Do B. Braun Standard Manifolds ensure safe backflow prevention?

Yes, B. Braun Standard Manifolds are designed with backcheck valves in each port to prevent backflow and enhance safety during fluid and drug delivery.

Do these manifolds offer a long shelf life?

Yes, the B. Braun Standard Manifolds offer a substantial total shelf life of 60 months (5 years). This ensures the product maintains its sterility and effectiveness for an extended period, which is ideal for inventory management in clinical settings.

Is the manifold designed for critical fluid control?

Yes, the B. Braun Standard Manifolds are specifically designed for use in critical care environments where precise fluid control is essential. They are ideal for managing fluid and drug delivery efficiency in settings such as:

  • Operating Rooms
  • Anesthesia Delivery Systems

These manifolds are engineered with two or three port normally closed valves and integrated backcheck valves to ensure optimized, controlled, and unidirectional flow, which is crucial for managing complex intravenous or intra-arterial setups.

Do B. Braun Standard Manifolds use normally closed valves?

Yes, B. Braun Standard Manifolds are specifically engineered to maximize fluid flow control and efficiency using normally closed valves.

This precise configuration ensures controlled delivery and includes critical safety features:

  • Valve Configuration: The manifolds utilize either two-port or three-port normally closed valves (injection only).
  • Unidirectional Flow Control: Essential backcheck valves are integrated into every port to prevent undesirable backflow, enhancing procedural safety and flow optimization.
Are these B. Braun manifolds designed for precise control?

Yes, B. Braun Standard Manifolds are specifically engineered for optimal fluid flow control and highly efficient fluid and drug delivery, which is essential for critical environments like the operating room.

Key features that ensure precision and safety include:

  • Controlled Administration: They utilize two or three port normally closed valves for precise, controlled administration in injection-only applications.
  • Safety Against Backflow: Each port integrates a backcheck valve to enforce unidirectional flow and prevent retrograde flow.
  • Material Safety: These manifolds are manufactured without DEHP or natural rubber latex, addressing common patient sensitivities.
  • Sterile Availability: The units are supplied sterile and have a long shelf life of 60 months.
What advanced valve configurations are offered?

The B. Braun Standard Manifolds line is optimized for precise fluid and drug delivery in anesthesia settings. All units are designed for patient safety, featuring backcheck valves in each port and manufacturing that is free of DEHP and natural rubber latex.

Currently, the available configuration is the Anesthesia Tri-Connector with Normally Closed Valves (Model 472026). This specialized configuration provides:

  • Two normally closed valves suitable for injection-only use.
  • A low priming volume of 1.2 mL.
  • It is supplied sterile, with 50 units per case.

Note: The previously available Anesthesia Triple Valve Manifold (Model 472090), which featured three low-profile valves and an in-line check valve, has been discontinued.

Are different valve configurations available?

Yes, B. Braun Standard Manifolds offer different configurations tailored for specific fluid management needs, both featuring normally closed valves and integrated backcheck valves in every port to ensure safety and unidirectional flow.

The two primary configurations are:

  • Anesthesia Tri-Connector (SKU BBN-472026): This configuration includes two normally closed valves designed for injection-only use. It has a priming volume of 1.2 mL and is packaged 50 units per case.

  • Anesthesia Triple Valve Manifold (SKU BBN-472090): This configuration features three normally closed, low-profile valves and includes an additional in-line check valve. It has a priming volume of 2.0 mL and is packaged 100 units per case. (Note: This variant has been discontinued by the manufacturer.)

Are these high-quality manifolds DEHP and latex-free?

The B. Braun Standard Manifolds are designed with patient safety and biocompatibility as a primary focus, ensuring they are free from common sensitizing materials:

  • They are not made with DEHP (Di-ethylhexyl phthalate).
  • They are not made with natural rubber latex.

In addition to these material exclusions, the manifolds are supplied sterile for immediate use in critical environments and feature integrated backcheck valves in each port for enhanced safety and controlled, unidirectional fluid flow.