Sale price$5,099.46
Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+

Description

The Wallach WA1000B Cryosurgical System includes the general purpose console and mobile base, standard.

Warranty: 5 Years (Freezer) / 1 Year (Console) - Free from Defects in Material and Workmanship.

The WA1000B Cryo Console System offers the ideal combination of easy-to-use controls and built in safety features. It uses the powerful Wallach LL100 two-trigger freezer for nitrous oxide (carbon dioxide units are designed differently due to the properties of the gas). Freeze and defrost only occur when triggered, and can be stopped instantly. A console-mounted switch must be activated to permit gas to flow into the freezer, and a color-coded gauge provides gas pressure reading at a glance. The Wallach temperature indicator gives surgeons unparalleled control and efficiency during cryosurgery.

The console system is used for a variety of gynecology and dermatology cryosurgical procedures.

A large selection of Wallach Reusable Sterilizable Cryotips and Disposable Plastic Shields (#900221AA) are available.

Features

Wallach WA1000B Cryosurgical System Features

  • All the advantages of the Wallach LL100 or LLCO2 Freezers.
  • Read the depth of freeze using an independent hypodermic thermocouple.
  • Temperature indicator with integrated timer for precise documentation.
  • Cart carries a single 20 lb cylinder.
  • Audible freeze timer starts when freezing temperature is reached and records total time the tip is actually freezing.

Configurations

Wallach WA1000B Cryosurgical System Configurations

  • #900506-1-N2O: Standard Console with LL100 Multi-Tip Freezer (N2O).
  • #900506-1-CO2: Standard Console with LLCO2 Multi-Tip Freezer (CO2).
  • #900506-2-N2O: Console with Digital Temp Indicator, Timer, and LL100 Multi-Tip Freezer with Thermocouple (N2O).
  • #900506-2-CO2: Console with Digital Temp Indicator, Timer, and LLCO2 Multi-Tip Freezer with Thermocouple (CO2).

Frequently asked questions

Is the system suitable for multiple procedures?

The Wallach WA1000B Cryosurgical System is specifically designed for a wide range of cryosurgical procedures in both gynecology and dermatology.

Does the standard mobile base support a gas cylinder?

Yes, the Wallach WA1000B Cryosurgical System includes a standard mobile base that provides essential mobility in a clinical setting.

Key features of the mobile base include:

  • Inclusion: It is a standard component supplied with the general purpose console.
  • Mobility: Equipped with wheels for easy movement.
  • Capacity: The cart is specifically designed to safely accommodate and carry a single 20 lb gas cylinder.
Which freezers are compatible with the system?

The Wallach WA1000B Cryosurgical System is compatible with both Wallach LL100 and LLCO2 Freezers. This allows for flexibility depending on whether you are using Nitrous Oxide (N2O) or Carbon Dioxide (CO2) gas options for your cryosurgical procedures.

Does the system include advanced control and safety features?

Yes, the Wallach WA1000B Cryosurgical System is engineered for superior safety and precise operational control, which is essential for accurate gynecological and dermatological procedures.

Key control and safety features include:

  • Instant Operational Control: Freeze and defrost cycles are governed by a two-trigger freezer system. Both actions only occur when actively triggered, and they can be stopped instantly by the clinician at any time.
  • Gas Flow Safety: Gas flow requires explicit activation via a console-mounted switch, preventing accidental cryogen release.
  • Precise Monitoring & Documentation: The system incorporates a dedicated Wallach temperature indicator for enhanced control. This indicator includes an integrated timer that starts automatically when the target freezing temperature is reached, ensuring accurate documentation of the freeze duration.
  • Pressure Monitoring: A highly visible, color-coded gauge allows clinicians to monitor gas pressure instantly.
  • Depth Measurement (Option): The system supports the use of an independent hypodermic thermocouple for accurately reading the depth of the freeze.
Does the Wallach system offer precise freeze control?

Yes, the Wallach WA1000B Cryosurgical System is engineered for highly precise control and accurate documentation, which is a key selling point for gynecological and dermatological procedures.

Key features ensuring this precise control and documentation include:

  • Instant Activation Control: Freeze and defrost cycles are governed by a two-trigger freezer system that allows cycles to be instantly started and stopped, providing immediate operational command.
  • Temperature Monitoring: The console incorporates a Wallach temperature indicator for enhanced control and real-time feedback.
  • Accurate Timing: The temperature indicator includes an integrated timer that automatically starts when the freezing temperature is reached, ensuring accurate documentation of the total active freeze time.
  • Depth of Freeze Measurement: An independent hypodermic thermocouple option is available to precisely read and document the depth of the freeze.
What precise control and safety features are included?

The Wallach WA1000B Cryosurgical System is engineered with multiple integrated features to ensure both safety and highly precise control during cryosurgical procedures.

Key features include:

  • Instant Stop Control: The freezer unit (LL100 or LLCO2) uses a two-trigger mechanism. Freeze and defrost actions are triggered only when activated and can be stopped instantly by releasing the triggers.
  • Operational Safety Switch: Gas flow requires activation via a console-mounted switch, acting as an essential safeguard against unintended operation.
  • Precision Temperature Monitoring: The console features a dedicated Wallach temperature indicator, ensuring enhanced, continuous control of the tip temperature. A color-coded gauge also provides immediate, visual monitoring of the gas pressure.
  • Optional Documentation Timer: Advanced configurations include a Digital Temperature Indicator and Timer. The audible timer starts only when the necessary freezing temperature is achieved, accurately recording the total time the tip is actively freezing for procedural documentation.
  • Freeze Depth Measurement: An independent hypodermic thermocouple is available (on select configurations) for practitioners to precisely read and document the depth of the freeze.
Does the system accommodate a 20 lb cylinder?

The Wallach WA1000B Cryosurgical System’s mobile base is designed to carry a single 20 lb cylinder, ensuring convenient mobility for your procedures.

Does the system offer precise temperature control?

Yes, the Wallach WA1000B Cryosurgical System is engineered for highly precise control and reliable performance during cryosurgery. It incorporates several advanced features to maximize efficiency and safety:

  • Precise Temperature Monitoring: The console is equipped with a dedicated Wallach temperature indicator for continuous, accurate monitoring during the procedure.
  • Instantaneous Control: Operation uses a robust two-trigger freezer mechanism (LL100/LLCO2). Freeze and defrost functions can be stopped instantly upon trigger release, providing surgeons with maximum control.
  • Safety Protocol: Gas flow is strictly regulated and only permitted when activated via a console-mounted switch, with system pressure continuously monitored via a color-coded gauge.
  • Advanced Documentation (Optional): Configurations featuring the Digital Temperature Indicator and Timer include an audible timer that starts automatically when the target freezing temperature is reached, accurately recording the total active freeze time for documentation purposes.
  • Freeze Depth Measurement (Optional): The system supports the use of an independent hypodermic thermocouple for accurately measuring the depth of the freeze.
Does the system offer precise freezing control?

Yes, the Wallach WA1000B Cryosurgical System is specifically designed for precision and safety in gynecological and dermatological procedures. It features multiple integrated mechanisms for enhanced control and accurate documentation:

  • Instantaneous Control: Freeze and defrost cycles are governed by a two-trigger mechanism. Actions only occur when activated and can be stopped instantly for rapid procedural management.
  • Temperature Monitoring: The console includes a Wallach temperature indicator providing surgeons with precise, real-time feedback on the freezing process.
  • Accurate Documentation: The temperature indicator integrates an audible freeze timer. This timer automatically starts recording only after the target freezing temperature is achieved, ensuring accurate documentation of the effective treatment duration.
  • Depth Measurement: For maximum procedural accuracy, an optional independent hypodermic thermocouple is available to accurately measure and monitor the depth of the freeze.
Does the system support different gas types?

Yes, the Wallach WA1000B Cryosurgical System provides flexibility by supporting two major types of cryosurgical gases, depending on the chosen configuration.

The system is compatible with the following Wallach freezer units:

  • Nitrous Oxide (N₂O): Used with the Wallach LL100 freezer.
  • Carbon Dioxide (CO₂): Used with the Wallach LLCO2 freezer.

Be aware that you must select the appropriate console configuration (N₂O or CO₂) at the time of purchase, as the CO₂ units are designed differently to accommodate the unique properties of carbon dioxide gas.