Condition:
-
Warranty:
- Weight: 0.66 lb
-
Learn more:
-
MFR:
Zoll
Ships from Manufacturer
-
MPN: 8900-4055-40
- Phone: (800) 348-9011
+Free Shipping*
Shop with Confidence
Free Shipping
Free Returns
Sales Tax Exemption
+Dedicated Account Managers
Frequently asked questions
Are these electrodes suitable for sterile OR use?
Yes, these Zoll Pro-padz are specifically engineered for use in a sterile hospital operating room environment.
Their design ensures the maintenance of the sterile barrier through a unique feature:
- A two-pouch system allows medical staff to place the posterior electrode prior to surgery.
- This guarantees that the necessary sterile barrier remains intact while allowing for pre-operative setup.
Furthermore, these are multi-function electrodes, supporting Defibrillation, Pacing, ECG Monitoring, and Cardioversion.
Which Zoll defibrillator series are these electrodes compatible with?
These Pro-padz electrodes are designed for broad compatibility across several key Zoll professional defibrillator platforms.
They can be used for Defibrillation, Cardioversion, Pacing, and ECG Monitoring with the following series:
- Zoll M Series
- Zoll E Series
- Zoll R Series
- Zoll X Series
This compatibility ensures seamless integration into existing hospital operating room equipment, supporting sterile procedures due to the product’s unique two-pouch system.
What is the shelf life of the Pro-padz electrodes?
The Zoll Pro-padz Sterile Multi-Function Electrodes have a shelf life of 9 months from the date of manufacture. The product warranty is valid until the electrode is used or reaches its expiration date.
Which high-quality conductive materials are used?
The Zoll Pro-padz are designed using premium materials to ensure highly efficient electrical transfer, resulting in a Low Impedance classification.
The key components include:
- Conductive Gel: A specialized Polymer hydrogel ensures reliable skin contact and optimal electrical transmission.
- Conductive Element: Tin is utilized as the core conductive element for superior performance.
Furthermore, the electrodes are sealed in Polyester foil peel-bound laminate packaging to maintain the necessary sterile barrier for hospital operating room use.
Does the two-pouch system ensure operating room sterility?
Yes, the Zoll Pro-padz are specifically designed for sterile operating room use. The unique two-pouch system ensures the integrity of the sterile field.
This innovative design provides a critical benefit for surgical procedures by:
- Enabling the safe, pre-surgical placement of the posterior electrode.
- Guarantying the maintenance of a sterile barrier throughout the preparation process.
Each pair of electrodes is factory new, sterile, and sealed in durable polyester foil peel-bound laminate packaging.
Do the lead wires offer generous reach?
Yes, the lead wires offer generous length, which is vital for use in the operating room.<ul><li>Each electrode pad features a 10-foot (3-meter) lead wire.</li><li>This ample length supports the product’s unique two-pouch system, ensuring the sterile placement of the posterior electrode before surgery while maintaining the sterile barrier.</li></ul>
How does the two-pouch system maintain sterility?
The unique two-pouch system is specifically engineered for use in the sterile hospital operating room (OR) environment. Its primary function is to maintain the critical sterile barrier throughout the procedure.
It achieves this by:
- Facilitating the placement of the posterior electrode before the surgery commences.
- Ensuring the electrode can be positioned safely without compromising the sterile field required for the surgical setting.
How long are the lead wires?
The lead wires attached to the Zoll Pro-padz electrodes measure 10 feet (3 meters) per electrode.
This length provides clinical staff with sufficient reach and flexibility for patient placement, which is especially beneficial for maintaining the sterile barrier and optimizing workflow in the hospital operating room (OR) environment.
Does the low impedance class optimize performance?
Yes, the Zoll Pro-padz electrodes are engineered with a Low Impedance classification, which is essential for optimized electrical performance during critical procedures in the operating room.
This design profile guarantees:
- Efficient Energy Delivery: Crucial for effective defibrillation and pacing.
- Reliable Signal Transmission: Ensures accurate ECG monitoring and cardioversion.
Reliable performance is facilitated by the use of specific high-quality conductive materials:
- Conductive Gel: Polymer hydrogel
- Conductive Element: Tin
What high-quality conductive materials are used?
The Zoll Pro-padz are engineered with specific materials to ensure high electrical performance and low impedance suitable for critical care environments:
- Conductive Gel: A specialized polymer hydrogel is used, ensuring reliable signal transmission and consistent adherence for effective monitoring and therapy delivery.
- Conductive Element: The metallic conductor utilized within the pads is Tin.
- Impedance Class: These electrodes feature a Low Impedance classification, which is crucial for maximizing electrical efficiency and safety during multi-function use (Defibrillation, Pacing, and ECG Monitoring).
Zoll Pro-padz Sterile Multi-Function ...