Does this system perform comprehensive testing?
Yes, the Welch Allyn TM286 AutoTymp is designed for comprehensive middle ear assessment by integrating three key measurement types into a single, portable device:
- Tympanometry: Measures middle ear function using a 226 Hz probe tone with rapid test times (approximately 1 second).
- Audiometry: Includes both automated and manual audiometry capabilities across frequencies from 125 Hz up to 8000 Hz.
- Acoustic Reflex Measurements: Measures ipsilateral acoustic reflexes at 500, 1000, 2000, and 4000 Hz.
Is the Welch Allyn TM286 AutoTymp system portable for on-site screenings?
Yes, the Welch Allyn TM286 AutoTymp system is lightweight (5 lb / 2.3 kg) and designed for portability, making it convenient for on-site screenings.
Does the audiometry testing cover a wide frequency range?
Yes, the TM286 AutoTymp covers a broad spectrum for audiometry testing, enabling comprehensive assessment. The system tests frequencies from 125 Hz up to 8000 Hz.
Key details regarding the frequency coverage and accuracy include:
- Tested Frequencies: 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, and 8000 Hz.
- Accuracy: The accuracy is specified as +/- 2% for frequencies between 125 Hz and 4000 Hz, and +/- 5 dB for 6000 Hz and 8000 Hz.
What components are included with the system?
The system package includes essential components needed for testing and documentation:
- Audiometry Headset (External)
- Threshold Audiometry Card
- Thermal Printer Paper (3 rolls)
- Ear-Tip Set (#26100)
What is the pressure range for tympanometry?
The Welch Allyn TM286 AutoTymp system uses a pressure range for tympanometry that spans from +200 to -400 daPa.
This precise measurement is achieved through:
- Pressure Accuracy: +/-10 daPa/sec.
- Sweep Control: The system automatically slows the sweep rate near the peak compliance point to ensure maximum accuracy.
- Sweep Direction: Positive to negative.
- Test Time: The entire tympanogram test is completed rapidly in approximately 1 second.
What specific voltage does the TM286 AutoTymp require?
The Welch Allyn TM286 AutoTymp is designed for flexible operation and accepts a wide voltage range:
- Input Voltage: 100 to 240 VAC (+/- 10%)
- Power Consumption: Maximum consumption is 16 watts while printing. It also uses a low-voltage input of 7 VDC, 5.0 A.
Is the tympanogram test rapid?
Yes, the Welch Allyn TM286 AutoTymp is designed for speed. The tympanogram testing is exceptionally rapid, taking approximately 1 second to complete the measurement. This contributes to fast and efficient screening in a clinical setting.
Is thermal paper required for the integrated printer?
Yes, the Welch Allyn TM286 AutoTymp system utilizes an integrated thermal printer for quick and convenient documentation of all test results (tympanograms, audiometry, and acoustic reflex measurements). This functionality allows for immediate hard-copy records to streamline your clinical workflow. The system package includes three rolls of thermal printer paper.
At what frequencies can acoustic reflex measurements be performed?
The TM286 AutoTymp can perform acoustic reflex measurements at frequencies of 500, 1000, 2000, and 4000 Hz for ipsilateral stimulation.
What are the dimensions and weight of the unit?
The unit is designed to be compact and lightweight, making it highly portable for various clinical settings.
Dimensions:
- Width: 12.5 inches (31.8 cm)
- Depth: 14.5 inches (36.8 cm)
- Height: 4.7 inches (11.9 cm)
Weight: Approximately 5 lb (2.3 kg)

Welch Allyn TM286 AutoTymp Tympanomet...