Regular price$4,355.40 Sale price$3,387.19
Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Welch Allyn CP 150 12-Lead Resting Electrocardiograph includes Power Cable, Patient Cable, Dust Cover, ECG Paper, ECG Electrodes, and 10 Crocodile Clips.

Warranty: 3 Years.

The Welch Allyn CP 150 12-Lead Resting Electrocardiograph combines the best traditional ECG features with connectivity enhancements designed for today's primary care facilities. It comes in a variety of different styles designed to suit your individual practice's needs. Optional spirometry, DICOM, and wireless capabilities can enhance the workflow of your clinic without adding significant cost to your initial purchase. Please read the configurations tab to see which system includes the capabilities you require.

Features

Welch Allyn CP 150 12-Lead Resting Electrocardiograph Features

  • ECG print previews can help save time and reduce paper costs.
  • Simplified EMR connectivity without a complicated interface.
  • 7" color, touchscreen display for easy entry of patient data.
  • Battery operation lets you easily transport your device to the patient.
  • Instant-on powers the device up quickly to take an ECG at a moment's notice.

Specifications

Welch Allyn CP 150 12-Lead Resting Electrocardiograph Specifications

  • Dimensions: 15" x 14.1" x 5.4" (381 mm x 358 mm x 136 mm).
  • Weight: 11.7 lb (5.3 kg).
  • Keyboard Type (power button): Polyester overlay.
  • Display Type: TFT, 18 cm (7") color touchscreen.
  • Display Resolution: WVGA, 800 x 480.
  • Instant On: Yes.
  • Thermal Paper: Z-fold 8.3" x 11" (21 cm x 28 cm); 200 sheets.
  • Gain Settings:
    • Auto ECGs: 2.5, 5, 10, or 20 mm/mV, AUTO.
    • Rhythm ECGs: 10, 25, or 50 mm/mV.
  • Lead Configurations: Standard, Cabrera.
  • Interpretation Algorithm: MEANS (Modular ECG Analysis System).
  • Common Mode Rejection Ratio (CMRR): Greater than 80 dB.
  • Input Impedance: Greater than 2.5 Ω
  • Patient Leakage: Less than 10 μA (normal condition), less than 50 μA (single fault condition).
  • Dynamic Range: AC differential +/- mV, DC offset +/- 300 mV.
  • Resolution: 2.5 μV.
  • A/D Conversion: 16 bits.
  • Heart Rate Range: 30 to 250 bpm.
  • Report Formats, Internal Printer:
    • Auto:
      • 3x4-2.5s @ 25 mm, 3x4-2.5s @ 50 mm, 3x4+1R-2.5s @ 25 mm.
      • 3x4+3R-2.5s @ 25 mm, 3x4-5.0s @ 25 mm, 3x4-5.0s @ 50 mm.
      • 6x2-5.0s @ 25 mm, 6x2-5.0s @ 50 mm,12x1-10.0s @ 25 mm.
    • Average Cycles: 3x4+3R @ 25 mm, 3x4+3R @ 50 mm, 6x2+1R @ 25 mm, 6x2+1R @ 50 mm, no print.
  • ECG Storage (in test directory): At least 100 ECG tests.
  • Frequency Range: 0.3 to 150 Hz.
  • Digital Sampling Rate: 8,000 samples/second/channel for data acquisition; 500 / 1,000 samples/second/channel for adult/pediatric ECG data analysis and storage.
  • Pacemaker Detection: ANSI/AAMI EC11.
  • Lead Detection: Lead off and noise.
  • Power Requirement: Universal AC power supply ~110–240 V, ~50/60 Hz, 1.5 A maximum.
  • AC Fuses: Time-lag type, 2.0-amp 250-V rating, Littlefuse 0218002P or equivalent.
  • Protection Against Electric Shock: Class I, internally powered type CF.
  • Rechargeable Battery: 10.8 V, 6.75 Ah (73 Wh), 9-cells Lithium-Ion. Recharge time to 90% capacity: 4 hrs. Full charge capacity—25 ECG tests @ 20 minutes/test. 8 hours of continuous operation or 250 continuous ECGs.
  • Filters:
    • High-Performance Baseline: 0.5 Hz.
    • Muscle Tremor: 35 Hz.
    • AC Interference: 50 Hz or 60 Hz.
  • Standard Connectivity: 1 USB client, 4 USB hosts and Ethernet.
  • Connectivity Options:
    • DICOM-compatible platforms (EMR, PACS, CVIS): Bidirectional capability with worklist download and ECG waveform upload. No middleware/software needed.
    • PDF to network folder, PDF to USB drive.
    • Electronic medical records: Through the Welch Allyn CardioPerfect WorkStation software. Middleware required (HL7 connectivity optional).
  • Electrodes: Rigorously tested for conductivity, adhesion and hypoallergenic qualities; exceed all AAMI standards.
  • Power Cable: Meets or exceeds Type SJT.
  • Patient Cable and Leads: Meets or exceeds ANSI/AAMI EC53, EN/IEC 60601-2-25 and EN/IEC 60601-2-51.
  • Environmental Operating Conditions:
    • Temperature: 10 degrees to 40 degrees C (50 degrees to 104 degrees F).
    • Relative Humidity: 15 to 95% noncondensing (30 to 70% for printing).
    • Atmospheric Air-Pressure Limits: 700 to 1060 hPa (525 to 795 mmHg).
  • Environmental Storage Conditions:
    • Temperature: -20 degrees to 50 degrees C (-4 degrees to 122 degrees F).
    • Relative Humidity: 15 to 95% noncondensing.
    • Atmospheric Air-Pressure Limits: 700 to 1060 hPa.
  • Mode of Operation: Continuous.

Configurations

Welch Allyn CP 150 12-Lead Resting Electrocardiograph Configurations

  • #CP150-1ENB: Noninterpretive.
  • #CP150A-1ENB: Automatic ECG Interpretation.
  • #CP150AW-1ENB: Automatic ECG Interpretation, Wireless.
  • #CP150W-1ENB: Wireless.
  • #CP150AD-1ENB: Automatic ECG Interpretation, DICOM.
  • #CP150AWD-1ENB: Automatic ECG Interpretation, Wireless, DICOM.
  • #CP150S-1ENB: Spirometry.
  • #CP150AS-1ENB: Automatic ECG Interpretation, Spirometry.
  • #CP150AWS-1ENB: Automatic ECG Interpretation, Wireless, Spirometry.
  • #CP150AWDS-1ENB: Automatic ECG Interpretation, Wireless, DICOM, Spirometry.

Frequently asked questions

Does it have instant-on for quick readings?

Yes, the Welch Allyn CP 150 features an Instant-On capability, allowing for quick startup and immediate ECG readings. This saves time and enhances workflow efficiency.

Does it include a high-performance battery?

Yes, the CP 150 includes a powerful, high-capacity Lithium-Ion battery to ensure maximum portability and efficient point-of-care diagnostics. This is further enhanced by the device’s Instant-On feature for immediate readiness.

Key specifications for the rechargeable battery are:

  • Type: 10.8 V, 6.75 Ah (73 Wh) Lithium-Ion.
  • Operational Capacity: The battery supports up to 8 hours of continuous operation or the capacity for approximately 25 ECG tests (calculated at 20 minutes per test) on a full charge.
  • Recharge Time: It recharges quickly, reaching 90% capacity in approximately 4 hours.
Can this ECG unit store many tests?

Yes, the Welch Allyn CP 150 is designed for robust data management and storage for busy primary care settings. The internal test directory is capable of storing at least 100 ECG tests.

This storage capacity works in conjunction with key features to streamline your clinical workflow:

  • Easy Review: Patient data and ECGs can be quickly accessed and reviewed directly on the large, 7-inch color touchscreen display.
  • Paper Efficiency: The screen preview feature allows you to examine stored ECGs before printing, helping to reduce paper waste.
  • Digital Workflow: Standard Ethernet and USB connectivity options allow for efficient transfer of stored data and integration with Electronic Medical Records (EMR) systems.
Does the CP 150 offer seamless EMR integration?

Yes, the Welch Allyn CP 150 is engineered for simplified EMR integration to enhance clinical workflow and data management.

Key features supporting digital connectivity and data transfer include:

  • Streamlined EMR Integration: The device offers straightforward connectivity to Electronic Medical Records (EMR) systems, avoiding complicated interfaces.
  • Optional DICOM Compatibility: When configured, it supports bidirectional DICOM data exchange, enabling worklist download and ECG waveform upload directly to EMR/PACS/CVIS systems without requiring external middleware.
  • Robust Standard Ports: Connectivity includes Ethernet, one USB client, and four USB host ports for flexible data transfer and saving.
  • PDF Output: ECGs can be saved as PDF files to a network folder or a USB drive.
  • Onboard Storage: The device has internal storage for at least 100 ECG tests in its test directory.
Does it use an advanced ECG interpretation algorithm?

Yes, the Welch Allyn CP 150 utilizes the MEANS (Modular ECG Analysis System) interpretation algorithm. This advanced functionality helps streamline clinical decision-making through comprehensive ECG data analysis. Please note that the interpretation capability is an optional configuration and must be selected when ordering the device.

Does the ECG have instant print previews?

Yes, the Welch Allyn CP 150 includes instant ECG print previews, enhancing efficiency and conserving resources.

Key features related to the preview include:

  • Intuitive 7-Inch Color Touchscreen: Facilitates clear, immediate visualization of the ECG data.
  • Review Before Print: Clinicians can easily preview the full ECG waveform and patient data directly on the 800 x 480 WVGA resolution display before committing to a printout.
  • Resource Management: This capability helps save both time and paper by ensuring the accuracy of the reading prior to printing.
What size thermal paper is used?

The Welch Allyn CP 150 uses Z-fold thermal paper for printing ECG results. This specific format is designed for easy management and storage. The specifications are:* Size: 8.3” x 11” (21 cm x 28 cm)* Capacity: The device holds up to 200 sheets.

Does it include an intuitive color touchscreen?

The Welch Allyn CP 150 includes a highly intuitive, 7-inch color touchscreen display (TFT, 800 x 480 resolution). This display is designed to simplify operation and enhance workflow efficiency in clinical settings.Key benefits of the touchscreen interface include:* Intuitive Operation: Facilitates easy and efficient entry of patient demographic data.* Resource Conservation: Allows users to preview ECG printouts on the screen, helping to conserve time and paper.* Clarity: The high resolution provides immediate and clear visualization of ECG waveforms and results.

What are the standard connectivity ports?

The Welch Allyn CP 150 includes robust, standard connectivity options crucial for efficient EMR integration and data management. These ports are included standard on the base unit:

  • Ethernet Port: For direct connection to your facility’s network.
  • 4 USB Host Ports: For connecting external peripherals or exporting data.
  • 1 USB Client Port: For communicating with a PC or centralized system.

Furthermore, optional enhancements like DICOM compatibility are available, allowing for bidirectional data exchange (worklist download and waveform upload) directly with EMR/PACS/CVIS systems without requiring middleware.

Does the ECG use a high digital sampling rate?

Yes, the Welch Allyn CP 150 uses a high digital sampling rate during data acquisition, which ensures superior fidelity and precise analysis of the ECG waveform, capturing even subtle cardiac activity. It’s a key feature for reliable performance.

The system uses specific sampling rates tailored to the stage of data handling:

  • Data Acquisition: The raw 12-lead ECG signal is captured at 8,000 samples/second/channel.
  • Analysis and Storage: The data is optimized for processing and storage based on the patient’s profile:
    • Adult ECG data: 500 samples/second/channel
    • Pediatric ECG data: 1,000 samples/second/channel