Sale price$2,156.65
Select a Configuration
Est. Delivery: 
<p>Earn%20[points_amount]%20when%20completing%20this%20purchase.</p>

Description

The Wallach LL100 Cryosurgical Unit includes the LL100 gun with gauge, tip holder, and N2O connection for 20 lb cylinder, standard.

Note: Tank is not included.

Warranty: 5 Years (1 Year - Unconditional + 4 Years - Free from Defects in Material and Workmanship) / 1 Year (Tips only).

The LL100 is a cryosurgical unit used for ablative-type surgical technique. The popularity of this procedure can be attributed to several factors: applicability to multiple organ systems, a wide range of disease indications (i.e., viral and premalignant tissue), rapid procedural times, relatively low-cost, office-based suitability, and minimal operative and post-operative complications.

Wallach's exclusive two-trigger design lets the physician precisely control both freeze and defrost. With twice the freeze power of other systems, the LL100 (nitrous oxide) performs both functions more effectively in less time eliminating treatment failures. Freeze and defrost only occur when triggered, and can be stopped instantly.

Light weight, well-balanced, and maneuverable, the unit provides full view of the target tissue. The gas hose allows for unimpeded surgical movement. Cryotips can be changed at any time without venting. A large selection of highly conductive reusable, sterilizable cryotips, and disposable plastic shields (#900221AA) are available.

The Wallach Cryosurgical Cryotips offer the ultimate in safety and convenience. The disposable shield can be removed from cryotips and discarded after each use. This allows cryotips to be sterilized. Avoid soaking tips, which may lead to problems caused by oversoaking (oversoaking may lead to tip corrosion). Shields are renewed with each procedure. They insulate tips, and assure proper attachment of the tip by serving as a positive stop. Whether you use the LL100 or the LLCO2, the tips are the same. There is a wide variety of tips available for every clinical situation.

Configurations

Wallach LL100 Cryosurgical Unit Configurations

  • #900001: Standard (No Tips Included).
  • #900001A-N2O: GYN Practice Package [includes all standard accessories plus GYN tips: T-1905 (exocervical), T-2514 (exo-endocervical), and T-0500 (5.0 mm-HPV)].

Note: The GYN Practice Package is pre-made by CooperSurgical for easy purchase. However, you may select any combination of three cryosurgical tips to suit your individual needs, at no extra cost. If you would like to select a custom tip package, please contact MFI Medical to personalize your order.

Accessories

Wallach LL100 Cryosurgical Unit Accessories

The following accessories are compatible and commonly purchased with the LL100 Cryosurgical Unit:

  • #900221AA: Disposable Plastic Shield (Box of 100).
  • #901011: Cylinder Cart - For Standard Size.
  • #901060: N2O Cylinder - Standard.

Frequently asked questions

Is the LL100 ideal for ablative surgery?

Yes, the Wallach LL100 Cryosurgical Unit is specifically designed and optimized for ablative-type surgical techniques. It utilizes nitrous oxide (N₂O) and is highly effective for treating a wide range of indications, including viral and premalignant tissue, making it ideal for cost-effective, office-based procedures.

Its superior performance and precision are ensured by:

  • Twice the Freeze Power: The unit delivers significantly greater freezing capability than competitive systems, ensuring treatments are performed effectively and quickly.
  • Exclusive Dual-Trigger Control: This mechanism grants the physician instantaneous, precise control over both the freeze and defrost cycles.
  • Optimal Maneuverability: The lightweight, well-balanced design ensures easy movement and maintains a full, unobstructed view of the target tissue during operation.
Which cryotips are included with the LL100?

The inclusion of cryotips depends entirely on the specific configuration you select:

  • Standard Configuration (#900001): This base package includes the LL100 gun and N₂O connection accessories, but no cryotips are included. Tips must be purchased separately.
  • GYN Practice Package (#900001A-N2O): This specialized package includes three specific gynecological tips:
    • T-1905
    • T-2514
    • T-0500 (5.0 mm-HPV)

A significant advantage of the LL100 system is its flexibility: it is compatible with a wide selection of highly conductive, reusable, and sterilizable cryotips. Crucially, tips can be changed at any time without venting the gas system, which greatly enhances procedural efficiency.

Is the connection for a 20 lb N₂O cylinder included?

Yes, the Wallach LL100 Cryosurgical Unit utilizes Nitrous Oxide (N₂O) as its power source. The standard package is designed for immediate setup and includes the necessary connection hardware for a standard 20 lb N₂O cylinder.

What is included:

  • LL100 gun with gauge
  • Tip holder
  • N₂O connection for 20 lb cylinder

What is not included: The N₂O tank/cylinder itself is not included with the unit and must be sourced separately.

Is the LL100 unit lightweight and maneuverable?

Yes, the Wallach LL100 is engineered for superior handling and excellent visibility, making it highly suitable for office-based settings. Key features include:

  • It is lightweight and well-balanced, ensuring precise and comfortable operation.
  • The design, supported by a gas hose, allows for unimpeded surgical movement.
  • It ensures a full, unobstructed view of the target tissue during the procedure.
Does it offer superior freeze power?

Yes, the Wallach LL100 Cryosurgical Unit offers twice the freeze power for more effective and quicker freeze and defrost cycles, enhancing treatment efficiency and patient comfort.

Does the unit require specialized care for cryotips?

To maintain the longevity and performance of your cryotips, please observe the following care guidelines: - Sterilization: The tips are fully sterilizable to ensure clinical safety. - Corrosion Prevention: It is crucial to avoid soaking the tips during cleaning, as this can lead to corrosion. - Proper Handling: Use the included disposable plastic shields to insulate tips and ensure secure attachment during surgical procedures.

Is the Wallach LL100 Cryosurgical Unit suitable for office-based procedures?

Yes, the Wallach LL100 Cryosurgical Unit is highly suitable for office-based surgical procedures due to its broad applicability and rapid procedural times.

Are disposable plastic shields available for the cryotips?

Yes, the Wallach LL100 Cryosurgical Unit utilizes disposable plastic shields, which are available (Part #900221AA, sold in a box of 100).

These shields are designed to work with the system’s highly conductive, reusable cryotips and provide several essential benefits:

  • Enhanced Insulation: They offer crucial insulation for the metal tips during the procedure.
  • Secure Seating: They ensure proper and positive tip attachment.
  • Sanitation: They maintain hygiene, as a new shield is used for each procedure.
Does the LL100 feature exclusive dual-trigger control?

Yes, the Wallach LL100 Cryosurgical Unit is defined by its exclusive two-trigger design. This system provides physicians with exceptional precision and control during procedures.

Key advantages of the dual-trigger mechanism:

  • Independent Control: Allows the physician to precisely manage both the freeze and defrost cycles independently.
  • Instantaneous Stops: The cycle can be initiated and stopped instantly, providing maximal control over treatment duration.
  • Enhanced Performance: This precision, combined with the LL100 having twice the freeze power of other systems, ensures highly effective and quick treatments.
Can cryotips be changed during a procedure without venting the Wallach LL100?

Yes, cryotips can be changed at any time without venting the Wallach LL100 Cryosurgical Unit.