Condition:
-
Country of Origin: USA
-
Warranty:
- Weight: 3.14 lb
- Less discomfort, bleeding, tissue abrasion than D and C method
- No cervical dilation necessary in most cases
- Sterilized and individually packaged
- Extracts a histological sample from the uterine mucosal lining in seconds
-
Learn more:
-
MFR:
CooperSurgical
Ships from Manufacturer
-
MPN: 908015
- Phone: (800) 243-2974
+Free Shipping*
Shop with Confidence
Free Shipping
Free Returns
Sales Tax Exemption
+Dedicated Account Managers
Frequently asked questions
Is the sampler diagnostically versatile?
Yes, the Wallach Endocell Sampler is highly versatile, providing a simple, safe, and economical method for obtaining histological samples from the uterine mucosal lining (endometrium). Its primary clinical applications include:
- Screening and Diagnosis: Used for the detection and screening of endometrial carcinoma and precancerous conditions.
- Monitoring Therapy: Valuable for monitoring the effects and efficacy of hormonal therapy regimens.
- Diagnostic Evaluation: Aids in diagnosing fertility problems and identifying uterine pathogens.
- Menstrual Extraction: Can also be utilized for menstrual extraction procedures.
Key Benefits
A core benefit of the Endocell is its minimally invasive design. The procedure is typically non-traumatic, requiring no cervical dilation in most cases, which results in significantly less patient discomfort, bleeding, and tissue abrasion compared to traditional Dilation and Curettage (D&C) methods.
It also features the unique True “O” Ring Design for superior sample collection results.
Is the Wallach Endocell Endometrial Cell Sampler a single-use device?
Yes, the Wallach Endocell is EtO sterilized and individually packaged for single use to ensure sterility and prevent cross-contamination.
Is cervical dilation usually avoided?
Yes, the Wallach Endocell Sampler is specifically designed for a simple, non-traumatic procedure. In most cases, cervical dilation is not necessary, which significantly reduces patient discomfort, bleeding, and tissue abrasion compared to the traditional D and C method.
What are the key dimensions of the Endocell sampler?
The Wallach Endocell Sampler is designed with slender dimensions that prioritize patient comfort and ease of use, often avoiding the need for cervical dilation.
Key specifications include:
- Outside Diameter: 3.1 mm
- Length: 24.3 cm
For safety and precision during the procedure, the sampler is equipped with numbered sounding marks spaced 1 cm apart, beginning at the 3 cm mark. Its moldable structure also facilitates easy insertion into markedly anteverted or retroverted uteri.
Does the Endocell ensure superior sample collection quality?
Yes, the Wallach Endocell is specifically engineered for superior and optimal histological sample collection from the uterine mucosal lining.
The quality of the sample collection is ensured by key design features:
- True “O” Ring Design: This sampler is the only one featuring a true “O” ring, which creates an optimal seal to maximize the manually generated suction.
- Rapid Suction Method: The device uses an elastomeric seal piston plunger to quickly generate suction, allowing the histological sample to be extracted efficiently in seconds.
- Non-Traumatic Procedure: Compared to dilation and curettage (D&C), the Endocell is less traumatic, helping to minimize bleeding and tissue abrasion during sample retrieval.
Does the sampler have safety sounding marks?
Yes, the Wallach Endocell Endometrial Cell Sampler includes numbered sounding marks to ensure precise and safe insertion depth during the procedure.These marks help guide accurate placement:
- They are spaced 1 cm apart.
- Numbering begins at the 3 cm mark.
This built-in feature aids in measurement precision and enhances safety, especially since the device is moldable for easy insertion into anteverted or retroverted uteri.
What are the primary uses of the Endocell sampler?
The Wallach Endocell Endometrial Cell Sampler is used to quickly and safely obtain a histological sample from the uterine mucosal lining (endometrium) using manual suction. This less-traumatic method is an excellent alternative to D&C procedures.
Its primary diagnostic applications include:
- Screening for endometrial carcinoma and precancerous conditions.
- Monitoring the effects of hormonal therapy.
- Diagnosing fertility problems and identifying uterine pathogens.
Key advantages of this device include its unique true “O” ring design for optimal sample collection and the fact that cervical dilation is not required in most cases.
How does the Endocell sampler ensure easy insertion?
The Wallach Endocell Endometrial Cell Sampler is designed with moldability, which allows for easy insertion even in cases of anteverted or retroverted uterus, enhancing patient comfort and procedural efficiency.
Is this procedure less traumatic for patients?
Yes, the Wallach Endocell Endometrial Cell Sampler is specifically engineered to be a non-traumatic alternative to traditional methods like dilation and curettage (D&C).
Its design and method prioritize patient comfort and safety, offering several key advantages:
- Reduced Discomfort and Bleeding: The manual suction technique and the sampler’s small 3.1 mm outside diameter minimize discomfort, bleeding, and tissue abrasion.
- Simplified Procedure: The device’s moldability assists insertion, and in most cases, no cervical dilation is necessary, which enhances patient ease.
- Rapid Sample Collection: The manual suction method allows the histological sample to be extracted quickly, often in seconds, contributing to a faster overall procedure.
Does it include safety sounding marks?
Yes, the Wallach Endocell Sampler is engineered for enhanced safety and precision during insertion and sampling. It features:
- Numbered sounding marks along the device exterior.
- Marks are spaced in 1 cm increments.
- The measurements begin at the 3 cm mark.
These marks provide critical guidance for accurate sample extraction from the endometrium.