Description

The Wallach Cryosurgical Tip - T-1920 Long Exo-Endocervical (#900212AA) is compatible with the popular LL100, LLCO2, and WA1000B Cryosurgical Systems, and delivers fast, precise freezing for cryosurgical procedures. The T-1920 Long Exo-Endocervical measures 19 mm in diameter, and protrudes 20 mm.

Warranty: 90 Days.

The T-1920 Long Exo-Endocervical tip has a disposable shield that can be removed from the tip and discarded after each use, which allows the tool to be sterilized. It's recommended that users avoid soaking the tips, in order to avoid tip corrosion. Shields are reapplied with each procedure, which insulate tips and assure proper attachment of the tip by serving as a positive stop.

Wallach Cryosurgical Tip Setup:

  • Remove disposable shield from cryosurgical tip and discard.
  • Plug the cryosurgical tip before cleaning and sterilizing.
  • Scrub tip to remove blood and particles.
  • Rinse with water.
  • Follow manufacturer's directions for appropriate steam sterilization.
  • Attach new disposable plastic shield to the cryosurgical tip.
  • The cryosurgical tip is now ready to use.

Frequently asked questions

Is the tip compatible with Wallach cryosurgical systems?
<p>Yes, the Wallach T-1920 Long Exo-Endocervical Tip is specifically engineered for <strong>seamless compatibility</strong> and precision performance with popular Wallach cryosurgical systems. It is designed for use with the following models:</p>

<ul>
<li><strong>Wallach LL100</strong></li>
<li><strong>Wallach LLCO2</strong></li>
<li><strong>Wallach WA1000B</strong></li>
</ul>
Is the T-1920 tip steam-sterilizable for reuse?
<p>Yes, the Wallach T-1920 tip is a reusable component suitable for multiple procedures when properly sterilized.</p>

<p>Here are the key details regarding its maintenance:</p>

<ul>
<li><strong>Reusable Tip:</strong> The main chrome/metal component of the tip is designed for longevity and reuse.</li>
<li><strong>Sterilization Method:</strong> It must be <strong>steam-sterilized</strong> after each use to maintain professional clinical standards.</li>
<li><strong>Disposable Shield:</strong> A crucial part of the process involves the <strong>disposable plastic shield</strong>. This shield must be removed and discarded after the procedure, allowing the metal tip to be thoroughly cleaned and sterilized. A new shield is then applied for the next use.</li>
<li><strong>Maintenance Note:</strong> To prevent corrosion, it is advised that users <strong>avoid soaking</strong> the metal tip during cleaning.</li>
</ul>
What is the diameter of the Wallach T-1920 cryosurgical tip?
<p>The Wallach T-1920 cryosurgical tip has a diameter of 19 mm.</p>
What is the protrusion length of the Wallach T-1920 cryosurgical tip?
<p>The Wallach T-1920 cryosurgical tip has a protrusion length of 20 mm.</p>
Is the T-1920 cryosurgical tip supplied with a disposable shield?
<p>Yes, the Wallach Cryosurgical Tip - T-1920 includes a disposable plastic shield. This shield is a crucial component designed to facilitate safe and sterile operation:</p>

<ul>
<li><strong>Enhances Sterility:</strong> The shield is removed and discarded after each procedure, which allows the reusable metal tip to be properly cleaned and steam-sterilized.</li>
<li><strong>Assures Attachment:</strong> It acts as a positive stop, ensuring the tip is correctly seated and insulated when attached to the cryosurgical unit (LL100, LLCO2, or WA1000B).</li>
</ul>
Is the Wallach T-1920 cryosurgical tip easy to sterilize?
<p>Yes, the Wallach Cryosurgical Tip (T-1920) is designed for <strong>reuse</strong> and can be effectively sterilized using steam. The system uses a reusable tip body paired with a disposable shield to ensure hygiene between procedures.</p>

<p><strong>Sterilization and Care Instructions:</strong></p>
<ul>
<li><strong>Preparation:</strong> Always remove and discard the disposable plastic shield before cleaning and sterilization.</li>
<li><strong>Method:</strong> The reusable tip body should be sterilized using <strong>steam sterilization</strong>.</li>
<li><strong>Post-Sterilization:</strong> Attach a new disposable shield before the tip is used in the next procedure.</li>
<li><strong>Important Care Note:</strong> Avoid soaking the tips during cleaning to prevent corrosion and maintain the integrity of the metal components.</li>
</ul>
What procedures is this specialized tip designed for?
<p>This specialized <strong>T-1920 Long Exo-Endocervical</strong> cryosurgical tip is designed for <strong>targeted cryogenic ablation</strong> in specific gynecological applications. It is intended for medical procedures requiring precise freezing control on <strong>endocervical or exocervical tissues</strong>.</p>
Is this tip designed for fast and precise freezing?
<p>Yes, the Wallach Cryosurgical Tip (T-1920) is engineered for <strong>fast and effective cryosurgery</strong>, providing the precision required for targeted exo-endocervical applications. Its design features ensure reliable integration and performance with compatible systems.</p>

<p>Key features supporting its precision and performance include:</p>

<ul>
<li><strong>Targeted Dimensions:</strong> The tip measures <strong>19 mm</strong> in diameter with a <strong>20 mm</strong> protrusion length, allowing for accurate tissue treatment.</li>
<li><strong>Optimal Compatibility:</strong> It is designed to work seamlessly with the Wallach LL100, LLCO2, and WA1000B Cryosurgical Systems.</li>
<li><strong>Sterilization Ready:</strong> The main tip component is metallic and reusable, intended to be steam-sterilized after removing the disposable shield.</li>
</ul>