- Condition: Factory New
- Country of Origin: USA
- Warranty: 90 Days
- Weight: 0.05 lb
- Includes a disposable shield
- Compatible with LL100, LLCO2, and WA1000B Cryosurgical Systems
-
Learn more:
- MFR: CooperSurgical Ships from Manufacturer
- MPN: 900201AA
- Phone: (800) 243-2974
Frequently asked questions
What Wallach systems are compatible?
This T-0219 Cone tip is engineered for seamless integration with several widely used Wallach Cryosurgical Systems. It is specifically compatible with the following models:
- LL100 Cryosurgical System
- LLCO2 Cryosurgical System
- WA1000B Cryosurgical System
This specific compatibility allows medical professionals to reliably use this reusable accessory across essential Wallach platforms.
Does this reusable tip include disposable shields?
Yes, the Wallach Cryosurgical Tip - T-0219 Cone includes disposable shields. While the metal tip is reusable and designed to be cleaned and steam sterilized between procedures, the attached plastic shield is disposable and must be removed, discarded, and replaced with a new one before each use.
The disposable shield is essential for both safety and performance, providing two key functions:
- It acts as a positive stop mechanism, ensuring proper and secure attachment to compatible Wallach Cryosurgical Systems (LL100, LLCO2, WA1000B).
- It insulates the tip during operation, protecting surrounding tissues.
How does the disposable shield enhance safety?
The disposable shield plays a critical role in safety and proper function, and it must be discarded after every procedure for hygiene.
It serves two primary purposes:
- Insulation: It insulates the cryosurgical tip during the procedure.
- Proper Attachment: It acts as a positive stop mechanism, ensuring the T-0219 Cone tip is attached correctly and securely to the Wallach Cryosurgical System (LL100, LLCO2, or WA1000B).
Does the tip include a hygienic disposable shield?
Yes, the Wallach Cryosurgical Tip - T-0219 Cone includes a disposable plastic shield that must be used and replaced for every procedure. This shield is integral to the safe and effective operation of the tip.
The disposable shield provides two main benefits:
- Ensures Proper Fit: It acts as a “positive stop” to guarantee the tip is securely and correctly attached to compatible Wallach systems (LL100, LLCO2, WA1000B).
- Insulation and Hygiene: It insulates the tip during the procedure and is discarded immediately afterward, ensuring a high standard of hygiene for the reusable tip.
What are the precise T-0219 tip dimensions?
The T-0219 Cryosurgical Tip features a specialized cone geometry engineered for precise and targeted application during procedures. The dimensions are fixed to ensure repeatable accuracy:
- Tip Type: Cone
- Tip Diameter: 2 mm
- Protrusion Length: 19 mm
This specific configuration is compatible with Wallach LL100, LLCO2, and WA1000B Cryosurgical Systems.
Is the T-0219 Cone cryosurgical tip reusable?
Yes, the Wallach Cryosurgical Tip (T-0219 Cone) is specifically designed for reusability across multiple procedures. Its construction allows it to be sterilized, offering long-term clinical value.
To maintain the tip and ensure proper hygiene, specific care steps must be followed:
- Sterilization: The tip component must be sterilized using steam sterilization, following the manufacturer’s detailed directions.
- Cleaning: The tip must be plugged before cleaning. Scrub the tip to remove any debris and rinse it afterward. Important: Do not soak the tip, as this can cause corrosion.
- Safety Feature: The tip includes a disposable shield that is crucial for insulation and ensuring proper attachment to the system. This disposable shield must be discarded and renewed after every single procedure.
Can the cryosurgical tip be soaked for cleaning?
No, avoid soaking the cryosurgical tips as it may lead to problems such as tip corrosion.
Is the Wallach cryosurgical tip reusable?
Yes, the Wallach Cryosurgical Tip (T-0219 Cone) is designed for durable, repeated reuse, providing long-term value.For proper use and sterility, the tip requires specific maintenance between procedures:* Sterilization: The main tip component must be cleaned and sterilized using steam sterilization.* Cleaning Protocol: Ensure the tip is plugged before cleaning, scrub to remove debris, and rinse thoroughly. Do not soak the tip to prevent potential corrosion.* Safety Feature: A new disposable plastic shield must be attached before each procedure. This shield provides insulation and acts as a positive stop for correct attachment to compatible systems (LL100, LLCO2, WA1000B).
Which company manufactures this tip?
This cryosurgical tip is manufactured by CooperSurgical. It is provided as a Factory New accessory, ensuring high quality and reliability. It is specifically designed for use with the highly utilized Wallach Cryosurgical Systems: LL100, LLCO2, and WA1000B.
What are the key specifications of this cone tip?
The T-0219 Cone tip is specifically engineered for precise cryosurgery applications and features a cone configuration with the following key specifications:
- Diameter: 2 mm
- Protrusion Length: 19 mm
This geometry is designed for accurate targeting and enables precise, controlled freezing applications when used with compatible Wallach Cryosurgical Systems.