Description

The Wallach Cryosurgical Tip - T-0200 2.5 mm HPV (#900300AA) is compatible with the popular LL100, LLCO2, and WA1000B Cryosurgical Systems, and delivers fast, precise freezing for cryosurgical procedures. The T-0200 2.5 mm HPV measures 2.5 mm in diameter.

Warranty: 90 Days.

The Wallach Cryosurgical Tips have a disposable shield that can be removed from the tip and discarded after each use, which allows the tool to be sterilized. It's recommended that users avoid soaking the tips, in order to avoid tip corrosion. Shields are reapplied with each procedure, which insulate tips and assure proper attachment of the tip by serving as a positive stop.

Wallach Cryosurgical Tip Setup:

  • Remove disposable shield from cryosurgical tip and discard.
  • Plug the cryosurgical tip before cleaning and sterilizing.
  • Scrub tip to remove blood and particles.
  • Rinse with water.
  • Follow manufacturer's directions for appropriate steam sterilization.
  • Attach new disposable plastic shield to the cryosurgical tip.
  • The cryosurgical tip is now ready to use.

Frequently asked questions

Is this tip compatible with popular Wallach systems?

Yes, the T-0200 2.5 mm HPV Cryosurgical Tip is specifically engineered for seamless integration with popular Wallach Cryosurgical Systems, ensuring fast and precise freezing.

It is fully compatible with the following models:

  • Wallach LL100
  • Wallach LLCO2
  • Wallach WA1000B

This tip is a vital, reusable accessory designed to work effectively with these systems.

Is the cryosurgical tip reusable and sterilizable?

Yes, the Wallach T-0200 Cryosurgical Tip is designed for reusability and requires proper sterilization between procedures.

Key guidelines for cleaning and reuse:

  • Sterilization Method: The reusable tip component must be cleaned and then sterilized using steam sterilization.
  • Cleaning Precaution: To maintain the tip’s integrity and prevent corrosion, users are strongly advised to avoid soaking the instrument during the cleaning process.
  • Disposable Shield: For hygienic operation, a new disposable plastic shield must be applied before each procedure. The used shield must be removed and discarded prior to cleaning and sterilization of the reusable tip.
What components are included?

The purchase includes the core, reusable instrument:

  • The Wallach Cryosurgical Tip (T-0200 2.5 mm HPV) (the reusable component).

Crucial Usage Requirement:

While the tip itself is reusable and sterilizable, it requires a disposable plastic shield for each procedure. This shield provides insulation and acts as a positive stop for attachment.

Please note: The disposable shield is NOT included with the tip purchase and must be sourced separately.

What does the disposable shield do?

The disposable plastic shield is a critical component that ensures hygiene, proper fit, and performance during cryosurgical procedures. It serves several vital functions:

  • Ensures Hygiene: The shield is removed and discarded after each procedure, facilitating the proper cleaning and steam sterilization of the reusable metal tip.
  • Secures Attachment: It acts as a positive stop mechanism, guaranteeing the reusable tip is correctly seated and securely fastened to the Wallach Cryosurgical System handle.
  • Provides Insulation: The shield provides necessary insulation during freezing, helping to achieve controlled and precise ablation.
What is the diameter of the Wallach Cryosurgical Tip - T-0200?

The diameter of the Wallach Cryosurgical Tip - T-0200 is 2.5 mm.

Is the T-0200 Cryosurgical Tip reusable?

Yes, the main metal tip of the T-0200 is designed to be reusable and fully sterilizable.

Key details regarding its use and maintenance are:

  • Reusability: The tip component can be used repeatedly after proper cleaning (scrubbing, rinsing, and plugging) and subsequent steam sterilization according to manufacturer guidelines.
  • Disposable Shield: A new disposable plastic shield is required for every procedure. This shield is crucial for insulating the tip and ensuring a positive stop for correct attachment to the Wallach Cryosurgical System.
  • Maintenance Caution: Users are strongly advised to avoid soaking the tips during the cleaning process to prevent material corrosion.
What is the model/part number for the Wallach Cryosurgical Tip - T-0200?

The model/part number for the Wallach Cryosurgical Tip - T-0200 is 900300AA.

Where is the Wallach Cryosurgical Tip - T-0200 manufactured?

The Wallach Cryosurgical Tip - T-0200 is manufactured in the USA.

Does it provide precise freezing?

Yes, the Wallach Cryosurgical Tip - T-0200 is designed to deliver fast and precise freezing for effective cryosurgical procedures.

How do I prevent corrosion on the reusable tip?

To ensure the longevity and prevent corrosion of the reusable metal tip, it is crucial to follow the specific maintenance guidelines:

  • Avoid Soaking: You must avoid soaking the tips during cleaning and preparation, as this is the primary instruction to prevent corrosion.
  • Cleaning and Sterilization: After removing the disposable shield, scrub the tip to remove all particles, rinse thoroughly, and then follow the manufacturer’s instructions for appropriate steam sterilization (the recommended method).

Proper adherence to this protocol is necessary to maintain the tip’s precision and integrity for repeated use.