- Condition: Factory New
- Weight: 4.7 lb
- 300-lb. weight capacity
- Vinyl coated, ergonomically contoured arm cuffs molded for comfort and stability
- Leg and forearm sections adjust independently for optimal sizing.
- Vinyl hand grips are comfortable and durable.
-
Learn more:
- MFR: Drive DeVilbiss Healthcare Ships from MFI Medical
- MPN: 10405
- Phone: (877) 224-0946
Frequently asked questions
Does the tube material improve patient comfort?
Yes, it is specifically engineered for comfort. The tube is constructed from a specialized medical-grade plastic that is formulated to soften at body temperature, which helps to minimize irritation to the neonatal airway during use.
How does the tip design minimize trauma?
The distal end features a smooth, molded, and gently cupped tip. This design is specifically crafted to reduce the risk of trauma during the insertion process, ensuring a safer experience for the neonate.
Can clinicians easily verify the intubation depth?
Absolutely. The tube is equipped with distal depth lines spaced at 1 cm intervals. These markings allow clinicians to accurately reference the tube’s position relative to the vocal cords, ensuring precision placement.
Is this tube suitable for both oral and nasal use?
Yes, the Sheridan Uncuffed Endotracheal Tube is versatile and designed to be utilized in both oral and nasal applications.
Is the material quality high enough for clinical use?
Yes, this is a factory-new, high-quality, sterile medical device manufactured by Teleflex LLC. It is designed to meet the rigorous demands of professional neonatal intensive care units, emergency care, and surgical settings.
Does the tube include a Murphy Eye?
Yes, the product is designed with a Murphy Eye tip, providing an additional safety feature for consistent airflow.
What are the precise dimensions of this neonatal tube?
This model is specifically sized for neonatal patients with the following dimensions:
- Inner Diameter: 2.5 mm
- Outside Diameter: 3.6 mm
- Total Length: 141 mm
Is the tube flexible for better handling?
Yes, the tube is constructed from clear, flexible plastic, allowing for easier navigation and placement while maintaining the necessary structural integrity for secure airway management.
Are there specific protocols for handling this device?
As this is a professional medical device, it should be handled according to standard clinical safety protocols. Please be advised that the materials used may pose a risk of cancer and reproductive harm if handled improperly, so strict adherence to medical safety guidelines is required.
Is the tube visibility clear for easier monitoring?
The tube is made from clear, transparent plastic, which offers excellent visibility to help clinicians monitor the airway and verify placement effectively during procedures.