Condition:
-
Warranty:
- Weight: 128.4 lb
- Perfect for quick instrument turn-around or a high volume office with its full penetration of steam and post-vacuum drying
- Chamber door remains closed during the entire cycle to maintain sterility and ensure efficient drying of packs and pouches
- Standard Cassettes Capacity: 3 full and 3 half
- Chamber Dimensions: 10" x 19" (254 mm x 475 mm)
- Volume: 15 - 50 L
- Technology: Steam Pressure
-
Learn more:
-
MFR:
Tuttnauer
Ships from MFI Medical
-
MPN: EZ10k
- Phone: (800) 624-5836
+Shipping
Shop with Confidence
Sales Tax Exemption
+Dedicated Account Managers
Frequently asked questions
What are the dimensions of the high-volume chamber?
The Tuttnauer EZ10k/2540EKA is engineered with a substantial chamber size to support high-volume offices and rapid instrument turnover, providing 6 gallons (23 Liters) of capacity.
Key physical dimensions and organization specifications are:
- Internal Chamber Dimensions: 10 inches (Diameter) x 19 inches (Depth) (254 mm x 475 mm)
- Cassette Capacity: The unit accommodates 3 full size (8” x 11”) and 3 half size (8” x 5.5”) standard cassettes.
- Number of Trays: It includes 4 dedicated trays for instrument organization, ensuring efficient use of the chamber volume.
How fast is the standard unwrapped cycle?
The Tuttnauer EZ10k/2540EKA is designed as a Fully Automatic Kwiklave to provide rapid turnaround, which is essential for high-volume settings.
The approximate total cycle times for standard unwrapped instruments are:
- Cold Start: Approximately 21 minutes
- Hot Start: Approximately 11 minutes
This speed is supported by a post-vacuum drying system that utilizes HEPA-filtered air circulation to ensure efficient and sterile drying of the load.
What voltage is required for operation?
The Tuttnauer EZ10k/2540EKA operates on a 230 V electrical supply.
It is essential that your power supply falls within the narrow operating range to ensure the full sterilization cycle and quick turnaround capabilities function reliably.
Key Power Specifications:
- Nominal Voltage: 230 V
- Required Operating Range: 220 V to 235 V
- Power Consumption: 2200 W
- Current Draw: 10 A
- Frequency: 50/60 Hz
Important Note: Users must verify that their facility’s electrical supply falls within the strict 220 V to 235 V range. If it does not, a buck/boost transformer may be required to meet the necessary input specifications.
Does the autoclave meet strict safety standards?
Yes, the Certified Refurbished Tuttnauer EZ10k/2540EKA complies with several crucial international quality and safety standards, confirming its reliability for clinical and medical environments.
The certifications met include:
- FDA Compliance: Required for medical devices in the US market.
- UL/EN 6010-1: Covers essential electrical safety and performance requirements.
- ISO 13485:2003: Specifies the quality management system requirements for medical devices.
- ISO 9001:2000: A widely recognized global quality management standard.
What is the cassette and tray capacity?
The Tuttnauer EZ10k/2540EKA Autoclave features a substantial 6-gallon (23 Liter) chamber (10 inches x 19 inches) designed for high-volume instrument sterilization. The maximum capacity allows for a combination of cassettes and sterilization trays:
- Cassette Capacity: The unit holds 6 standard cassettes simultaneously:
- 3 full-size cassettes (8” x 11”)
- 3 half-size cassettes (8” x 5.5”)
- Tray Capacity: The autoclave comes equipped with 4 sterilization trays for loose or unwrapped instruments. Each tray measures 16.3 inches (Depth) x 6.7 inches (Width) x 0.8 inches (Height).
What does the certified refurbishment include?
The Tuttnauer EZ10k/2540EKA is designated as Certified Refurbished and undergoes extensive pre-sale servicing to ensure its performance meets or exceeds original manufacturer specifications.
This comprehensive reliability process includes:
- New Components: Installation of a new Preventative Maintenance (PM) kit, including a new gasket and filters.
- System Integrity: A complete system flush is performed.
- Calibration: Full system calibration to manufacturer specifications.
- Sterilization Verification: Successful execution of a spore test to verify sterilization efficacy.
For assurance of compliance and quality, the unit meets stringent regulatory standards, including **FDA, UL/EN 6010-1, ISO 13485:2003, and ISO 9001:2000}.
Are multiple sterilization programs included?
Yes, the Tuttnauer EZ10k/2540EKA Kwiklave Autoclave includes four fully automatic sterilization programs designed for optimal results and rapid throughput across different loads.
This system offers versatility with the following standard cycles:
- Unwrapped instruments
- Wrapped instruments/packs
- Glassware
- A dedicated drying cycle
A significant advantage is that all program parameters are fully customizable and can be stored for quick, repeated use.
What new parts are installed during refurbishment?
The Tuttnauer EZ10k/2540EKA is a Certified Refurbished unit, guaranteeing high performance right out of the box. As part of the comprehensive servicing, a brand new Preventative Maintenance (PM) kit is installed prior to shipment.
The new components installed include:
- New Gasket: Ensures a perfect, secure seal is achieved throughout every steam sterilization cycle.
- New Filters: Maintains system purity and operational efficiency.
This installation is part of a thorough process that also encompasses complete calibration to manufacturer specifications, a full system flush, and verification via spore testing.
What items are included with this refurbished autoclave?
Each certified refurbished Tuttnauer EZ10k/2540EKA comes ready for reliable use with the following items:
- Autoclave Unit: A fully tested and calibrated sterilization system.
- Power Cable: Required for operation.
- Preventive Maintenance Kit: A new kit containing essential components like gaskets and filters is professionally installed prior to shipping to ensure peak performance.
For facilities requiring documentation, please note that an internal printer is an available configuration option for this unit.
Does it have a HEPA filter?
Yes, the Tuttnauer EZ10k/2540EKA autoclave is equipped with a 0.2 µm replaceable HEPA filter. This filter helps ensure the quality of air within the chamber, contributing to the maintenance of sterility during the drying cycle.