Regular price$29,500.00 Sale price$25,063.60
Est. Delivery:
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Tuttnauer 3870HSG-WS Pre and Post Vacuum Autoclave is an 85 liter sterilizer that's designed for large clinics and ASC's. It produces hospital grade sterilization with a medium load capacity, and is most ideal for medical clinics, dental clinics, and operating rooms.

Warranty: 2 Years.

Note: Standard MFI freight charges do not apply. An install/freight charge will need to be special-quoted by Tuttnauer.

As the name suggests, the 3870HSG-WS Pre and Post Vacuum Autoclave contains a built-in vacuum system designed for fractionated pre vacuum air removal and post vacuum drying. This removes air pockets from the chamber to ensure full steam sterilization on the entire load. The post vacuum process dries the load efficiently for a bone-dry finish.

The HSG-WS model specifically has been designed for water saving, through an efficient recycling system. In total, it will utilize only five liters of tap water per day. In terms of utility connection, it can be hooked up to existing utilities for distilled water, tap water, and electricity, or can be independent of utilities with only a power connection needed. With the independence feature, the water reservoirs must be manually filled prior to cycles.

Safety features include double-locking doors to prevent accidental openings while the chamber is pressurized, as well as a control lock-out switch that won't start a cycle until the door is locked.

Technical Standards and Compliance

The Tuttnauer 3870HSG-WS Pre and Post Vacuum Autoclave fulfills the following directives and standards:

Quality Standards

  • ISO 9001:2015 - Quality Management Systems.
  • EN ISO 13485:2016 Quality Management System – Medical Devices.
  • In compliance with 21 CFR part 820 & part 11.

Directives

  • MDD 93/42/EEC amended in Directive 2007/47/EEC.
  • PED 2014/68/EU - Pressure Equipment Directive.
  • 2012/19/EU WEEE and 2017/2102 RoHS.

Technical Standards

  • EN 285: 2015 Large steam sterilizer.
  • EN 61010-1: 2010.
  • EN 61326-1: 2013.
  • EN 61010-2-40: 2015.
  • FDA Approved.
  • ANSI/AAMI/ST8:2013 (R2018).
  • ANSI/AAMI - ST55:2016.
  • ASME Code section I and section VIII. Div.I.

Features

Tuttnauer 3870HSG-WS Pre and Post Vacuum Autoclave Features

  • For medical clinics, dental clinics, and operating rooms.
  • Built-in vacuum system designed for pre vacuum air removal and post vacuum drying.
  • Uses up to five liters of tap water per day.
  • Can be connected to utilities for water, or stand independent and be manually filled with water.
  • Double-locking doors and control lock-out switch prevents accidental openings.

Specifications

Tuttnauer 3870HSG-WS Pre and Post Vacuum Autoclave Specifications

  • Chamber Dimensions: 15.2" x 29.9".
  • Chamber Volume: 85 liters.
  • Number of Trays: 2.
  • Tray Dimensions:
    • Small: 11.3" x 1" x 26.6".
    • Large: 13.8" x 1" x 26.6".
  • Overall Dimensions: 28.4" x 53.8" x 46.5".
  • Weight: 397 lb.
  • Voltage/Frequency: 3 ph, 230 Volts, 25 Volts, 25 Amp, 60 Hz.
  • Power: 9 kW.

Literature

Tuttnauer 3870HSG-WS Pre and Post Vacuum Autoclave Literature

Tuttnauer 3870HSG-WS Pre and Post Vacuum Autoclave Brochure

Frequently asked questions

How does the powerful vacuum system ensure sterilization?
<p>The Tuttnauer 3870HSG-WS employs a sophisticated vacuum system that operates in two crucial phases to ensure both hospital-grade sterilization and efficient drying:</p>

<ul>
<li><strong>Fractionated Pre-Vacuum:</strong> This cycle actively removes air pockets from the chamber and the entire load before sterilization begins. This air removal is essential to guarantee complete <strong>steam penetration</strong> for full sterilization.</li>
<li><strong>Post-Vacuum Drying:</strong> After the sterilization phase is complete, the post-vacuum process efficiently extracts residual moisture, ensuring the instruments and materials achieve a <strong>bone-dry finish</strong>.</li>
</ul>
How much water does the Tuttnauer 3870HSG-WS Autoclave consume?
<p>The Tuttnauer 3870HSG-WS autoclave is designed for water conservation, using only about five liters of tap water per day thanks to its efficient recycling system.</p>
What are the utility connection options for the Tuttnauer 3870HSG-WS Autoclave?
<p>The Tuttnauer 3870HSG-WS Autoclave can be connected to existing utilities for distilled water, tap water, and electricity. Alternatively, it can operate independently with only a power connection, requiring manual filling of the water reservoirs.</p>
What safety features does the Tuttnauer 3870HSG-WS Autoclave offer?
<p>The Tuttnauer 3870HSG-WS Autoclave is equipped with advanced safety features to ensure secure operation:</p>

<ul>
<li><strong>Double-locking doors</strong> are designed to prevent the door from being opened while the chamber is pressurized.</li>
<li>A <strong>control lock-out switch</strong> prevents the autoclave from starting a cycle unless the door is properly secured.</li>
</ul>
What are the power requirements?
<p>The Tuttnauer 3870HSG-WS Autoclave requires a robust 3-phase electrical connection with the following specifications:</p>

<ul>
<li><strong>Voltage:</strong> 230 Volts</li>
<li><strong>Phase:</strong> 3 phase</li>
<li><strong>Amperage:</strong> 25 Amp</li>
<li><strong>Frequency:</strong> 60 Hz</li>
<li><strong>Power Consumption:</strong> 9 kW</li>
</ul>
Does this autoclave provide hospital-grade sterilization?
<p>The Tuttnauer 3870HSG-WS is specifically designed for hospital-grade sterilization, ensuring thorough and reliable sterilization of instruments. It utilizes a pre- and post-vacuum system to effectively eliminate air pockets and achieve complete steam sterilization, followed by efficient drying for a bone-dry finish.</p>
Which quality standards does the Tuttnauer 3870HSG-WS Autoclave meet?
<p>The Tuttnauer 3870HSG-WS Autoclave adheres to extensive quality, safety, and performance standards, ensuring hospital-grade sterilization. It is <strong>FDA Approved</strong> and complies with:</p>

<ul>
<li><strong>Quality Management &amp; Directives:</strong> ISO 9001:2015, EN ISO 13485:2016, 21 CFR part 820 &amp; part 11, MDD 93/42/EEC (amended by 2007/47/EEC), PED 2014/68/EU, WEEE 2012/19/EU, and RoHS 2017/2102.</li>
<li><strong>Technical &amp; Safety Standards:</strong> EN 285: 2015, EN 61010-1: 2010, EN 61326-1: 2013, EN 61010-2-40: 2015, ANSI/AAMI/ST8:2013 (R2018), ANSI/AAMI - ST55:2016, and ASME Code section I and section VIII. Div.I.</li>
</ul>
Where is the 3870HSG-WS autoclave most effective?
<p>The Tuttnauer 3870HSG-WS Autoclave is designed for optimal performance in demanding large clinical environments, including:</p>

<ul>
<li><strong>Medical clinics</strong></li>
<li><strong>Dental clinics</strong></li>
<li><strong>Operating rooms</strong></li>
<li><strong>Surgical centers</strong></li>
</ul>

<p>It is ideal for facilities that require <strong>hospital-grade sterilization</strong> and can handle medium load capacities efficiently.</p>