Condition:
-
Warranty:
- Weight: 107.0 lb
- Chamber Dimensions: 10" x 19" (254 mm x 475 mm)
- Provides quick instrument turnaround for high volume labs and clinics
- Primarily used by veterinarians or surgeons but also used in a range of other settings, including active surgery centers, medical practices, dental offices, schools, doctor's clinics, or tattoo establishments
- Automatic shut off at the end of both the sterilization and dry cycles
- Volume: 15 - 50 L
- Technology: Steam Pressure
-
Learn more:
-
MFR:
Tuttnauer
Ships from MFI Medical
-
MPN: 2540M
- Phone: (800) 624-5836
Frequently asked questions
Does the autoclave offer generous cassette capacity?
Yes, the Tuttnauer 2540M is engineered for high-volume environments and offers generous cassette capacity within its large 10” x 19” chamber.
It is designed to hold the following standard cassette sizes:
- Full Cassettes (8” x 11”): 3 cassettes
- Half Cassettes (8” x 5.5”): 3 cassettes
Additionally, the unit includes capacity for 4 standard instrument trays.
Is this high-capacity autoclave versatile for clinical use?
Yes, the Tuttnauer 2540M is highly versatile, engineered for high-volume professional environments requiring quick, dependable sterilization. Its large 6-gallon (23 L) chamber capacity makes it an ideal solution for facilities needing greater instrument throughput.
This durable unit is commonly utilized across a wide range of professional settings, including:
- Medical and Surgery Centers: Essential for quick turnaround of surgical and clinical instruments.
- Dental Offices: Efficiently sterilizes dental tools and accommodates standard full and half cassettes.
- Veterinary Clinics: Provides reliable sterilization for animal care equipment.
- Tattoo Establishments: Ensures compliance and sterility of all implements.
- Laboratories and Schools: Used for reliable sterilization of necessary lab equipment.
Does this autoclave have fast sterilization cycles?
Yes, the Tuttnauer 2540M is designed for quick instrument turnaround, which is essential for high-volume professional settings. The approximate times for standard unwrapped instrument sterilization are:
- Cold Start: Approximately 30 minutes
- Hot Start: Approximately 14 minutes
Starting with a hot chamber significantly reduces the overall cycle time, ensuring maximum efficiency and fast turnaround in busy clinical environments.
Does this autoclave use standard 120V power?
Yes, the Tuttnauer 2540M Manual Autoclave is designed for easy integration into professional settings as it operates on standard 120 V electrical power.
Key electrical specifications are:
- Voltage: 120 V
- Frequency: 50/60 Hz
- Power Rating: 1400 W
- Current Draw: 12 A
Is the drain valve easily accessible?
Yes, the drain valve for the Tuttnauer 2540M is designed for easy maintenance and accessibility.
- The drain valve is conveniently located on the front of the unit.
- This placement allows for simple and straightforward draining of the water reservoir, contributing to efficient upkeep and operation in high-volume environments.
Does this professional autoclave include necessary maintenance supplies?
Yes, the Tuttnauer 2540M Manual Autoclave is delivered ready for clinical use and includes the following essential items:
- Main Autoclave Unit: A high-capacity 23-liter (6-gallon) sterilization system featuring a durable, electro-polished 316L stainless steel chamber.
- Power Cable: A standard power cord for 120 V operation.
- Preventative Maintenance Kit: Includes a replacement gasket and filters to help you maintain consistent performance and longevity right from the start.
This system provides a reliable, high-volume sterilization solution designed for efficiency and safety in demanding medical, dental, and laboratory environments.
Does this autoclave ensure reliable sterilization?
The Tuttnauer 2540M is engineered for reliable steam pressure sterilization in demanding clinical and laboratory settings. Its performance is supported by robust construction and multiple automated safety features that ensure cycle integrity and consistency:
- Durable Construction: The chamber and door are constructed from electro-polished 316L stainless steel for longevity.
- Automated Shut-off: The unit features automatic shut-off upon completion of both sterilization and dry cycles.
- Overheat Protection: Equipped with dual safety thermostats to protect the unit against overheating.
- Pressure Safety: A double safety locking device prevents the door from being opened while the chamber is pressurized.
- Water Management: Includes an insufficient water detector to ensure proper operating conditions.
Does the 2540M include automatic shut-off?
Yes, the Tuttnauer 2540M is equipped with an automatic shut-off feature designed for enhanced safety and convenience. This function activates automatically at the completion of both the sterilization cycle and the drying cycle.
Is the 2540M autoclave considered high-capacity?
Yes, the Tuttnauer 2540M is explicitly designed for high-volume sterilization and quick instrument turnaround, making it ideal for busy clinical and laboratory settings.
It features a large chamber to maximize throughput compared to smaller models:
- Chamber Volume: 6 gallons (23 L)
- Chamber Dimensions: 10 inches x 19 inches (254 mm x 475 mm)
This substantial capacity allows the autoclave to hold:
- Trays: 4 standard trays
- Cassettes: Up to 3 full (8” x 11”) and 3 half (8” x 5.5”) standard cassettes.
Does the autoclave feature enhanced safety?
Yes, the Tuttnauer 2540M is engineered with enhanced safety features for reliable, secure operation, especially during high-volume use. These mechanisms comply with current sterilization standards and protect both the unit and the operator.
Key safety components include:
- Double Safety Locking Device: This system prevents the door from being opened while the chamber is still under pressure.
- Dual Safety Thermostats: These provide reliable protection against overheating.
- Automatic Shut-Off: The unit automatically shuts off at the conclusion of both the sterilization and dry cycles.
- Insufficient Water Detector: This system monitors the water reservoir level to help prevent unit damage and ensure effective steam generation.