Sale price$73.88
Select a Wire Length
Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Technomed Twisted Disposable Subdermal EEG Needle Electrodes (20 Pairs per Package) are designed to minimize the risk of postoperative neurological effects on patients.

Warranty: Until Use or Expiration (3 Year Shelf Life).

The electrodes come as a twisted pair with 1.5, 2, or 2.5 meter PVC wires available in 10 color combinations, which connect into safety DIN 42 802 connectors. These electrodes are 13 mm x 0.40 mm (27 Gauge) in size, made of stainless steel, and feature a 2 x 10 color combination (black or white with red, green, orange, yellow, and blue).

The electrodes are individually packed, pre-sterilized, and have a shelf life of 36 months when unopened. Electrodes have gone through the ethylene oxide (EtO) sterilization process.

Note: Do not use these electrodes for stimulation of any kind.

Features

Technomed Twisted Disposable Subdermal EEG Needle Electrodes Features

  • Clear and reliable signal.
  • Twisted pair aids in noise reduction.
  • Smooth penetration and repositioning.
  • Color coded lead wires for ease of use.
  • Single use to avoid cross-patient contamination.

Wire Lengths

Technomed Twisted Disposable Subdermal EEG Needle Electrodes Wire Lengths

  • #TE/S44-637: 1.5 m (60").
  • #TE/S44-837: 2 m (80").
  • #TE/S44-937: 2.5 m (100").

Literature

Technomed Twisted Disposable Subdermal EEG Needle Electrodes Literature

Technomed Product Catalogue

Technomed Disposable Subdermal Needle Electrodes Portfolio Datasheet

Frequently asked questions

What are the precise stainless steel needle dimensions?

The electrodes feature durable stainless steel needles (27 Gauge) specifically engineered for reliable subdermal insertion during EEG monitoring.Their precise dimensions are:* Needle Gauge: 27 Gauge* Length x Diameter: 13 x 0.40 mm

Are these high-quality electrodes pre-sterilized?

Yes, these Technomed subdermal needle electrodes are supplied pre-sterilized and are designed exclusively for safe, single-use applications.

Key details regarding their sterilization and readiness for use include:

  • Sterilization Method: Each electrode pair is individually packaged and sterilized using the industry-standard Ethylene Oxide (EtO) process.
  • Disposable Design: They are intended for single use only, ensuring maximum hygiene and preventing cross-contamination.
  • Extended Shelf Life: Unopened packages maintain a guaranteed shelf life of 3 years (36 months), valid until the expiration date or time of first use.
What wire lengths are offered?

These disposable subdermal EEG needle electrodes are offered in three different wire lengths to provide setup flexibility for various clinical needs:

  • 1.5 m
  • 2.0 m
  • 2.5 m
Do the EEG electrodes have a long shelf life?

Yes, these disposable subdermal EEG electrodes offer a guaranteed shelf life of 36 months (3 years) when the packaging remains unopened. This extensive shelf life helps ensure the electrodes maintain their sterility and readiness for use.

What materials are used for the needles and wires?

The Technomed subdermal electrodes utilize durable, clinical-grade materials for high-precision EEG signal acquisition:

  • Needle Material: The needles are constructed from Stainless Steel and measure 13 x 0.40 mm (27 Gauge), designed for reliable subdermal placement.
  • Wire Material: The connecting leads are made of flexible PVC (Polyvinyl Chloride). They feature a twisted pair configuration which helps minimize interference and maintain signal integrity during recording.
  • The wires terminate in standard safety DIN 42 802 connectors.
Do these electrodes use precise 27 Gauge needles?

Yes, these disposable subdermal electrodes feature high-quality stainless steel needles designed for reliable application. The precise specifications are:

  • Needle Dimensions: 13 x 0.40 mm
  • Needle Gauge: 27 Gauge (27G)
Do these electrodes use secure connectors?

Yes, these Technomed subdermal electrodes are designed for secure connectivity using industry-standard Safety DIN 42 802 connectors. These connectors ensure reliable signal acquisition during EEG monitoring.

Do these electrodes use a specialized twisted pair configuration?

Yes, these Technomed Subdermal EEG Needle Electrodes are supplied in a twisted pair configuration.

This crucial design feature helps to minimize electrical interference and signal noise, ensuring optimized signal integrity for clear and reliable EEG recordings.

Key specifications regarding the wiring and connectivity include:

  • Wire Material: Constructed with durable PVC.
  • Connector Type: Terminated with industry-standard safety DIN 42 802 connectors.
  • Color-Coding: Features 2 x 10 color combinations (black or white wires paired with five distinct lead colors) for easy channel identification.
  • Available Lengths: You can choose from three wire lengths to accommodate various clinical setups: 1.5 m, 2.0 m, and 2.5 m.
How many electrode pairs are included?

Each package of the Technomed Twisted Disposable Subdermal EEG Needle Electrodes includes a total of 20 pairs.

These twisted-pair electrodes are individually packaged and pre-sterilized using the Ethylene Oxide (EtO) process, ensuring they are ready for immediate, single-use application in clinical settings.

How are the electrodes color-coded?

The electrodes feature a clear 2 x 10 color combination designed for efficient channel identification and lead management during electroencephalography (EEG) procedures. This coding system uses two primary base colors combined with five distinct accent colors:

  • Primary Wire Colors (Base): Black or White
  • Secondary Lead Colors (Accents): Red, Green, Orange, Yellow, and Blue

Furthermore, the wires are supplied in a twisted pair configuration, which helps maintain organization and minimize interference during use.