Description

The SleepSense SUM Channel, Semi-Reusable Inductive System (# 9212-Kit) includes the adult large inductive belt (# 9002-L90), adult XL inductive belt (# 9002-L120), and a Multi-Rip Inductive Interface Module with a SUM Channel Kit (# 9201-Kit).

Warrranty:

  • Inductive Plethysmography Belts: 60 Days - Free of Defects in Materials and Quality Workmanship.
  • SUM Channel Module Kit: 1 Year - Free of Defects in Materials and Quality Workmanship.

The SleepSense SUM Multi-RIP Module Kit (# 9201-Kit) that is included in this kit detects both chest and abdomen effort signals simultaneously and has the capability to provide a summation of the 2 channels. This kit includes SUM-Abdomen Cable (# PS9202), SUM-Chest Cable (# PS9203), SUM-Output Cable (# PS9204), standard connectors, and AAA batteries. The kit connects to any SleepSense RIP/inductive band.

The reusable inductive belts have a buckle closure, are fully adjustable, and can be used with any SleepSense interface cable or with your current RIP/inductive system.

NOTE: SleepSense items are for professional use only, and are for sale by or on the order of a physician only.

SleepSense SUM Channel, Semi-Reusable Inductive Kit Specifications:

  • Recommended Filter Settings (Multi-Rip SUM Module):
    • High Pass: 50 Hz.
    • Low Pass: 500 Hz, or as recommended in the system's instructions.
  • Operating Conditions: 40 to 104 °F.
  • Storage Temperature: -4 to 140 °F.
  • Operating and Storage Humidity: 5 to 95% (non-condensing).

SleepSense SUM Channel, Semi-Reusable Inductive Kit Literature:

SleepSense Semi Reusable Inductive Belts User Manual

SleepSense Multi-Rip SUM Module User Manual

Buying SleepSense SUM Channel, Semi-Reusable Inductive Kit from MFI Medical

Product details

Category
RIP/Inductive Technology
Manufacturer part number
9212-Kit
MFI SKU
SLS-9212-Kit

Supplier, condition & warranty

Supplier
MFI Medical Equipment, Inc.
Brand
SleepSense
Condition
Factory New
Listed warranty
Not Available

MFI Medical is an authorized distributor for all new SleepSense items we sell. The warranty for this item is listed as “Not Available.” Contact MFI Medical if you need clarification about coverage.

Healthcare purchasing support: MFI Medical provides formal quotations, accepts purchase orders, and offers payment terms to approved customers. W-9 and vendor onboarding information and purchase order and payment instructions are available online.

Purchasing and warranty assistance: MFI Medical: (800) 633-1558. Contact MFI Medical · Warranty policy. Manufacturer product support: (888) 757-7367.

Price & shipping

MPNCondition & warrantyItem price (USD)
9212-KitMFI SKU: SLS-9212-KitFactory NewWarranty: Not Available $820.00 Free shipping*

*Free standard shipping to the contiguous U.S. on eligible orders of US$35 or more. Other destinations and upgraded services cost extra. Shipping policy

Frequently asked questions

Does the kit provide dual-channel signal summation?

Yes, this kit is specifically designed for comprehensive respiratory monitoring.

  • The system uses the included Multi-Rip SUM Module Kit to simultaneously acquire effort signals from both the chest and the abdomen via inductive belts.
  • A key feature of this module is its ability to output the summation (SUM channel) of these two signals, providing a comprehensive, single data stream for respiratory effort.
What items are included in the kit?

This professional-grade kit provides all the essential components for dual-channel respiratory effort monitoring and summation.

The complete SleepSense SUM Channel kit includes:

  • Interface Module: Multi-Rip Inductive Interface Module with SUM Channel Kit (# 9201-Kit)
  • Semi-Reusable Inductive Belts (Buckle Closure):
    • Adult Large Inductive Belt (# 9002-L90)
    • Adult XL Inductive Belt (# 9002-L120)
  • Necessary Cables:
    • SUM-Abdomen Cable (# PS9202)
    • SUM-Chest Cable (# PS9203)
    • SUM-Output Cable (# PS9204)
  • Standard connectors
  • AAA batteries (for the module)
Does the system offer signal summation?

Yes, the SleepSense SUM Channel kit’s central component, the Multi-Rip Inductive Interface Module with SUM Channel Kit, is specifically engineered for this purpose. It provides comprehensive respiratory effort monitoring by:

  • Simultaneously acquiring effort signals from both the chest and abdomen via the inductive belts.
  • Outputting a summation (sum channel) derived from these two signals, providing a holistic view of the patient’s respiratory effort.

This capability is a key selling point, vital for professional polysomnography (PSG) applications.

What sizes of inductive belts are included?

The kit includes both Adult Large (#9002-L90) and Adult XL (#9002-L120) inductive belts, ensuring compatibility with different patient sizes.

Does the module provide dual-channel signal summation?

Yes, the included Multi-Rip SUM Module Kit (part of the #9201-Kit) provides this essential functionality for professional sleep studies.The module performs:* Simultaneous Detection: Acquires respiratory effort signals from both the chest and abdomen channels.* Summation Output: Outputs a single summation (SUM) channel derived from the combination of the chest and abdomen signals.

Are the high-quality inductive belts reusable?

Yes, the inductive belts included in the SleepSense SUM Channel kit are specifically designed to be semi-reusable.

This designation indicates enhanced durability and suitability for long-term utility and repeated use in professional sleep study applications. The belts are fully adjustable and feature a secure buckle closure for optimal fit and compatibility with various RIP/inductive systems.

What are the humidity requirements for operating and storing the SleepSense SUM Channel Kit?

The operating and storage humidity should be between 5 to 95% (non-condensing).

Is a prescription required to purchase the SleepSense SUM Channel, Semi-Reusable Inductive Kit?

Yes, this product is available for purchase by or on the order of a physician only.

What are the storage temperature requirements for the SleepSense SUM Channel Kit?

The storage temperature should be between -4 to 140 °F.