Sale price$3,849.08
Estimated Delivery:
%3Cp%3EEarn%20[points_amount]%3C/p%3E

Description

Sklar's Kerrision non-detachable rongeur thin footplates and an ejector is used in spinal laminectomy procedures of the vertebral arch. The profile size allows for use in delicate areas near the spinal cord. This black Titanium Nitride (TiN) Coating surface protects the instrument for durability and smoothness, reducing the need for frequent sharpening. This version has a 40 degree down angled tip, and is available in different lengths and bite sizes.

Disposable Or Reusable reusable
Family rongeurs
Grade sklar or grade
Handle Style pliers with springs
Instrument Curvature straight
Instrument Length 7"
Instrument Material stainless steel with titanium nitride (tin) coating
Is Sterile non-sterile
Is Taa Compliant taa compliant
Latex Free not made with natural rubber latex
Surname kerrison
Tip Config downwards cutting bite (40 degrees)
Type laminectomy punch rongeur
Uom ea
Uom Description 1 each

Buying Sklar Kerrison Rongeur - 7", Downwards Cutting (40°), 1mm Tip, Thin Footplate, Titanium Nitride Coated - 42-5701 from MFI Medical

Product details

Manufacturer part number
42-5701
MFI SKU
SKL-42-5701

Supplier, condition & warranty

Supplier
MFI Medical Equipment, Inc.
Brand
Sklar
Condition
Factory New
Listed warranty
Lifetime

MFI Medical is an authorized distributor for all new Sklar items we sell. Any included warranty on a new item is provided directly by the manufacturer. MFI Medical is available to assist with manufacturer warranty claims.

Healthcare purchasing support: MFI Medical provides formal quotations, accepts purchase orders, and offers payment terms to approved customers. W-9 and vendor onboarding information and purchase order and payment instructions are available online.

Purchasing and warranty assistance: MFI Medical: (800) 633-1558. Contact MFI Medical · Warranty policy. Manufacturer product support: (610) 756-7863.

Price & shipping

MPNCondition & warrantyItem price (USD)
42-5701MFI SKU: SKL-42-5701Factory NewWarranty: Lifetime $3,849.08 Free shipping*

*Free standard shipping to the contiguous U.S. on eligible orders of US$35 or more. Other destinations and upgraded services cost extra. Shipping policy

Frequently asked questions

Does the Titanium Nitride coating improve durability?

Yes, the Titanium Nitride (TiN) coating is a key feature that provides superior surface hardness and wear resistance. This specialized black finish significantly enhances the tool’s longevity, ensuring the cutting edge remains sharp for much longer durations compared to standard stainless steel instruments.

Is this instrument suitable for delicate spinal procedures?

Absolutely. It is specifically engineered for precision in spinal laminectomy procedures. The thin footplate and 1mm tip size are optimized for maneuverability and safe, controlled bone removal within the confined anatomical spaces near the spinal cord.

How does the ejector mechanism assist the surgeon?

The instrument features an integrated ejector mechanism that helps reliably clear bone fragments during use. This design ensures that the rongeur remains effective and clear during complex procedures, preventing build-up that could impede the surgeon’s progress.

Is the construction robust for frequent daily use?

Yes, this is a professional-grade, surgical-grade stainless steel instrument. It features a spring-loaded pliers design that provides consistent performance and high reliability, specifically built to handle the rigors of frequent clinical laminectomy procedures.

Can I safely reuse this rongeur?

Yes, this instrument is fully reusable. It is designed to be maintained using standard surgical instrument sterilization protocols suitable for high-quality stainless steel medical devices.

Is this tool safe for patients with latex allergies?

Yes, the Sklar Kerrison Rongeur is 100% latex-free, as it is not manufactured using any natural rubber latex, making it safe for patients with latex sensitivities.

What is the benefit of the 40-degree downward cutting angle?

The 40-degree downward cutting tip is designed to provide optimal access. This specific geometry allows surgeons to achieve precise bone removal in tight spaces where a standard straight tip might be less effective or ergonomic.

Does the handle design support ergonomic control?

The handle features a spring-action mechanism that promotes comfortable, controlled operation. This ergonomic design reduces hand fatigue and allows for the fine motor control necessary during delicate neurosurgical or orthopedic procedures.

Does this tool meet federal procurement standards?

Yes, this product is TAA compliant, making it suitable for procurement and use in environments that require adherence to the Trade Agreements Act.

How does the coating affect the tactile experience?

Beyond increasing the hardness of the tip, the Titanium Nitride coating provides a smooth surface texture. This reduced friction allows for a more fluid and tactile experience, giving the surgeon better feedback while navigating delicate tissue.