Condition:
-
Warranty:
- Weight: 82.33 lb
- Uses a steam generator to sterilize and Dri-Tec Radiant Heat Drying Technology to dry instruments following sterilization
- Often used by surgeons and dentists, and is fast enough to sterilize expensive LASIK, PRK, endoscopic and cataract instruments, including phaco handpieces, between procedures
- Sterilization Chamber Volume: 5.1 L (170 fl oz U.S.)
- Small enough to fit onto a portable cart
- Volume: 1 - 15 L
- Technology: Steam Pressure
-
Learn more:
-
MFR:
SciCan
Ships from MFI Medical
-
MPN: Does not apply
- Phone: (800) 221-3046
+Free Shipping*
Shop with Confidence
Free Shipping
Free Returns
Sales Tax Exemption
+Dedicated Account Managers
Frequently asked questions
Does the autoclave offer rapid sterilization?
Yes, the SciCan Statim 5000 is engineered for high-speed sterilization.
It utilizes a fully automatic steam generator to achieve a complete sterilization cycle in as fast as nine minutes. This rapid turnaround is essential for minimizing downtime in operating rooms and surgical environments.
Furthermore, it includes Dri-Tec Radiant Heat Drying Technology to ensure instruments are dry immediately following the sterilization process.
What are the cassette's internal dimensions?
The SciCan Statim 5000 is designed with a high-capacity cassette system, providing a chamber volume significantly larger than the Statim 2000 model. This makes it suitable for sterilizing larger instrument loads and complex tools quickly.
Key capacity specifications are:
- Internal Cassette Dimensions (L x W x H): 15” x 7.1” x 3” (380 mm x 180 mm x 75 mm)
- Total Sterilization Chamber Volume: 5.1 L (170 fl oz U.S.)
How many sterilization cycles does the 4 L reservoir support?
The SciCan Statim 5000 Autoclave features a generous 4 L water reservoir, which supports an extended period of operation.
This capacity is sufficient for approximately 40 sterilization cycles before a refill is necessary. This minimizes maintenance and is ideal for clinical settings that require high-volume, continuous use.
How fast are the sterilization cycles?
The SciCan Statim 5000 Autoclave is specifically designed for high-speed sterilization to ensure rapid instrument turnaround in demanding medical environments. Its key features contributing to efficiency include:
- Fastest Cycle Time: The unit can complete a full sterilization cycle in as fast as nine minutes.
- Efficient Drying: It uses proprietary Dri-Tec Radiant Heat Drying Technology to ensure instruments are completely dry and ready for immediate use right after the cycle finishes.
This high speed, combined with a substantial 5.1 L sterilization chamber volume, significantly minimizes downtime between procedures.
What is included with this certified refurbished Statim 5000?
Each certified refurbished SciCan Statim 5000 Autoclave arrives fully prepared for clinical use. To ensure optimal performance and reliability, every unit undergoes a comprehensive refurbishment process, including a full system flush, calibration to manufacturer specifications, and final spore testing to confirm sterilization efficiency. The following components are included:
- Main Statim 5000 Autoclave Unit: The compact, high-capacity cassette sterilization system.
- Power Cable: Standard cable for immediate setup.
- Preventative Maintenance Kit: Includes a newly installed gasket and filters for consistent, high-quality operation.
- Water Bottle Kit: Necessary for maintaining the unit’s internal reservoir.
Is the Statim 5000 easy to install?
Yes, the SciCan Statim 5000 Autoclave is designed for plug-and-play operation and maximum flexibility:
- No Dedicated Installation: The unit only requires a standard wall socket for power and does not need any specialized or dedicated plumbing.
- Compact Placement: Its size allows it to be placed on a portable cart, making it suitable for in-room sterilization within an operating room or procedure suite.
- Fully Automatic: Once powered, it operates as a fully automatic cassette sterilizer, simplifying the entire sterilization process.
Does the unit undergo a rigorous refurbishment process?
Yes, each SciCan Statim 5000 is meticulously restored to meet high clinical standards. The certified refurbishment process includes: * System Calibration: The autoclave is fully calibrated to align with original manufacturer performance specifications. * Component Updates: Each unit is equipped with a new preventative maintenance kit, which includes a fresh gasket and filters, as well as a new water bottle kit. * Performance Testing: Every unit undergoes a rigorous spore test to ensure it delivers reliable, hospital-grade sterilization results before leaving the facility.
Is the Statim 5000 easy to install electrically?
Yes, the SciCan Statim 5000 is designed for operational simplicity and portability. It requires no complex installation or plumbing; you only need to plug it directly into a standard electrical wall socket.
The autoclave is highly flexible and supports operation on multiple electrical ratings (all operating at 50/60 Hz):
- 100 V (11 A)
- 110 V (11 A)
- 220 V - 240 V (6 A)
Its compact design means it can easily fit onto a portable cart and be used immediately in various clinical environments.
Does the optional printer help with compliance?
The SciCan Statim 5000 is available in a configuration with an optional built-in thermal printer. This feature is highly beneficial for record-keeping and regulatory compliance.
Its purpose is to provide a physical, tangible record (a hard copy receipt) of every sterilization cycle completed by the unit. This documentation is essential for maintaining an accurate audit trail, which is required for quality assurance and meeting regulatory standards in medical, dental, and surgical environments.
Does the Statim 5000 have large sterilization capacity?
Yes, the SciCan Statim 5000 Autoclave is designed with an ideal capacity suitable for sterilizing specialized and high-value instruments, such as endoscopic or surgical equipment, between procedures quickly.
Key capacity specifications are:
- Sterilization Chamber Volume: The unit offers a generous 5.1 L (170 fl oz U.S.) volume.
- Cassette Internal Dimensions: The cassette measures 15” L x 7.1” W x 3” H (380 mm x 180 mm x 75 mm), accommodating sensitive or larger instruments.
- Reservoir Capacity: The 4 L reservoir provides water for approximately 40 sterilization cycles.