Sale price$2,978.01
Select a Configuration

5+ In Stock

Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+

Description

The Ritter M9 UltraClave Automatic Sterilizer includes four instrument trays, a stainless steel tray rack, power cord, and a new pre-installed PM (preventative maintenance) kit which includes a new gasket and filters. This unit is fully calibrated to manufacturer specifications, passes spore testing, and has undergone a complete flush of the system.

Warranty: 90 Days - Parts and Labor.

The Ritter M9 UltraClave Automatic Sterilizer sets a time for you after you select your cycle. Press "start" and the M9 fills with the correct amount of water.

The M9 UltraClave Sterilizer features an intuitive LCD display and simple prompts that help you easily select the cycle you need, whether for unwrapped items, pouches, packs, or handpieces. Once the sterilization cycle is complete, the door automatically opens quietly to dissipate the steam and provide fast, efficient drying of your instruments.

This steam pressure autoclave is used in a range of settings, including active surgery center, medical practice, schools, veterinary facility, industrial lab, doctor's clinic, or tattoo establishment.

Features

Ritter M9 UltraClave Automatic Sterilizer Features

  • Reliable and effective for infection control assurance.
  • Patented automatic-opening door for efficient, safe instrument drying.
  • Steam-flush pressure pulse air removal system ensures proper steam penetration.
  • Self Program Controls: Programmable controls allow for creation of different cycle parameters for special sterilization needs.
    • Time: 3 to 90 minutes.
    • Temperature: 230 to 275 °F.
    • Dry Time: 0 to 60 minutes.
    • Vent: Slow or fast.
  • Pre-Programmed Controls:
    • Unwrapped: 270 °F or 132 °C for 3 minutes.
    • Pouched: 270 °F or 132 °C for 5 minutes.
    • Packs: 250 °F or 121 °C for 30 minutes.
  • LCD Display: Indicates cycle selected, temperature, and exposure time for selected cycle. During the cycle, the display shows messages describing status of cycle. When the cycle enters sterilization mode, remaining time is displayed as well as temperature and pressure.
  • Simply load it, set it and forget it.
  • Maximum space utilization and a complementary design for your sterilization area.
  • Reservoir fill port and drain tube located in the front of the unit for ease of draining and filling.
  • Meets CAN/CSA C22.2 No. 61010-1, CSA C22.2 No. 61010-2-040-07 Part 2-040.

Specifications

Ritter M9 UltraClave Automatic Sterilizer Specifications

  • Dimensions: 20.13" (L) x 15.3" (W) x 15.8" (H) (51 cm x 38.9 cm x 40.1 cm).
  • Length with Plug: 20.4" (51.8 cm).
  • Countertop Area: 17.88" (D) x 15.3" (W) (45.4 cm x 38.9 cm).
  • Pouch Rack: 1.
  • Chamber Dimensions: 9" (Diameter) x 15" (Depth) (22.9 cm x 38.1 cm).
  • Chamber Volume: 3.5 gallon (13.4 liters) usable volume.
  • Trays:
    • Two Large: 12" (L) x 7.3" (W) x 0.8" (D) (30.5 cm x 18.6 cm x 2.2 cm).
    • Two Small: 12" (L) x 5.6" (W) x 0.8" (D) (30.5 cm x 14.3 cm x 2.2 cm).
  • Weight:
    • Unit Weight: 73 lb (33.1 kg).
    • Shipping Weight: 81 lb (36.7 kg).
  • Water Reservoir Capacity: 1.1 gallons (4.1 liters).
  • Electrical Requirements: 115 VAC, 50/60 Hz, 15 Amps Single Phase.
  • ASME certified.
  • Installation: Use on a level, water-resistant material such as laminate, stainless-steel, or stone surface. Allow 2" (5.08 cm) on sides and rear, and 5" (12.7 cm) above to allow space to fill reservoir and change the printer paper roll.

Configurations

Ritter M9 UltraClave Automatic Sterilizer Configurations

  • #MFI-MMK-M9-022-PREVIOUS: MPN #M9-010; Includes four instrument trays. 1st Generation Autoclaves include M9-001, M9-002, M9-003, M9-004, M9-005, M9-006, M9-007, M9-008, M9-009, and M9-010.
  • #MFI-MMK-M9-022: 2nd Generation - Includes four instrument trays, stainless steel tray rack, and power cord.

Accessories

Ritter M9 UltraClave Automatic Sterilizer Accessories

The following accessories are compatible and commonly purchased with the M9 UltraClave Automatic Sterilizer:

  • #MFI-MMK-9A155001: Midmark M9/M11 Thermal Printer - First Generation (Compatible with #MFI-MMK-M9-022-PREVIOUS).
  • #MFI-MMK-9A259001: Midmark M9/M11 Thermal Printer - Second Generation (Compatible with #MFI-MMK-M9-022).
  • #002-0371-00: M9/M11 Printer Refill Kit.
  • Speed-Clean Chamber Cleaner:
    • #002-0396-00: Single Bottle.
    • #002-0396-05: Case (12 Bottles).
  • #9A226001: M9/M11 Sterilizer Pouch Rack.
  • #9A307001: Tray and Cassette Removal Tool.

Frequently asked questions

Is the certified refurbished unit fully calibrated?

Yes, this Certified Refurbished Ritter M9 UltraClave is thoroughly prepared and tested to ensure immediate, dependable operation and compliance.

The refurbishment process includes:

  • Full Calibration: The unit is precisely calibrated to meet all original manufacturer specifications.
  • Performance Verification: It has successfully passed required spore testing, confirming its ability to achieve effective, reliable sterilization.
  • Preventative Maintenance: A new PM kit, including a new gasket and filters, is pre-installed.
  • Regulatory Compliance: The sterilizer is ASME certified and meets relevant CAN/CSA safety and electrical standards.
How efficient is the automatic drying cycle?

The Ritter M9 UltraClave is engineered for fast, efficient, and safe instrument drying, primarily due to its advanced features:

  • Patented Automatic-Opening Door: Upon completion of the sterilization cycle, the door automatically and quietly opens. This immediately releases steam from the chamber, which is the key action ensuring rapid and efficient instrument drying.
  • Customizable Drying: Users can precisely tailor the drying process. Utilizing the Self Program Controls, the dry time can be set anywhere from 0 up to 60 minutes to accommodate different load types and sizes.
What is the chamber size and usable capacity?

The Ritter M9 UltraClave Automatic Sterilizer provides ample capacity for effective instrument sterilization. The key chamber specifications are:

  • Chamber Dimensions: 9 inches in diameter by 15 inches in depth (22.9 cm x 38.1 cm).
  • Usable Volume: 3.5 gallons (13.4 liters).

To help organize items during the sterilization process, the unit includes four instrument trays (two large, two small) and a stainless steel tray rack.

What are the electrical requirements for the Ritter M9 UltraClave?

The unit requires 115 VAC, 50/60 Hz, and 15 Amps Single Phase.

Can I customize the sterilization cycles?

Yes, the Ritter M9 UltraClave is designed for versatile operation. It features an intuitive LCD display that includes several pre-programmed cycles for standard items to simplify your daily workflow. For specialized needs, the unit also offers self-programmable controls, allowing you to customize key cycle parameters including:

  • Exposure Time
  • Temperature Settings
  • Vent Settings

This “set and forget” system ensures that once you select your cycle and press start, the unit handles the water intake and sterilization process automatically, providing real-time feedback on status, pressure, and remaining time.

Does this sterilizer include everything needed for immediate use?

Yes, the unit arrives fully prepared for professional operation. It includes a comprehensive starter package featuring: <ul><li>Four instrument trays (two large, two small)</li><li>A stainless steel tray rack</li><li>A high-quality power cord</li><li>A pre-installed PM kit, which includes a brand-new gasket and filters to ensure optimal sealing and filtration performance right out of the box.</li></ul>

Does this sterilizer work well for various clinical instruments?

Yes, the Ritter M9 UltraClave is highly versatile. It features pre-programmed cycles specifically optimized for:

  • Unwrapped instruments
  • Pouched items
  • Packs
  • Handpieces

Additionally, if you have specialized requirements, the unit offers Self-Program controls, allowing you to fine-tune the time, temperature, and drying phases to match your specific medical or laboratory needs.

How large is the conveniently located water reservoir?

The water reservoir has a usable capacity of 1.1 gallons (4.1 liters). A key feature for simplified maintenance is that both the fill port and the drain tube are conveniently located at the front of the unit, which facilitates quick and easy draining and filling.

Does the sterilizer use advanced air removal?

Yes, the Ritter M9 UltraClave ensures thorough sterilization by using an advanced Steam-flush Pressure Pulse air removal system.

This key feature guarantees effective steam penetration, which is vital for sterilizing various load types like pouched items and packs.

Key benefits of this system include:

  • Optimal Steam Coverage: Ensures saturated steam reaches all areas of the load for reliable infection control.
  • Rapid Drying Cycle: The advanced air removal works in conjunction with the patented automatic-opening door, which dissipates steam quietly post-cycle, promoting fast and efficient instrument drying.
  • Ease of Use: The process is automated, relying on the intuitive LCD interface for simple cycle selection.
Does this sterilizer simplify daily maintenance routines?

Yes, the M9 UltraClave is engineered for effortless maintenance and workflow efficiency. It features:

  • Accessible Design: A front-loading water reservoir and dedicated drain tube make fluid management simple and clean.
  • Ready-to-Use State: Every certified refurbished unit arrives with a pre-installed preventative maintenance kit, which includes a brand-new gasket and filters, ensuring peak performance right out of the box.
  • Clear Status Indicators: The integrated LCD screen keeps you informed with real-time monitoring of time, temperature, and pressure, minimizing the need for manual troubleshooting.