Sale price$59.26
Select a Package Quantity
Est. Delivery: 
<p>Earn%20[points_amount]%20when%20completing%20this%20purchase.</p>

Description

The Rhythmlink Disposable Extended Monopolar Stimulating Probe is a unique probe designed for spinal and peripheral nerve stimulation during lateral spinal approaches, extreme lateral spinal approaches [XLIF], and minimally invasive spinal surgeries. Insulated down to the semispherical non-tramautic tip, this robust probe aids in the identification of the genitofemoral nerve to provide safe surgical access. This versatile probe can be used for spinal and peripheral nerve identification, as well as pedicle hole and pedicle screw testing.

Warranty: Until Use or Expiration.

Longer than traditional monopolar probes, the Extended Monopolar Stimulating Probe is unique in its design: 160 mm insulated shaft ending in a semispherical non-traumatic 1.6 mm tip.

Features

Rhythmlink Disposable Extended Monopolar Stimulating Probe Features

  • Molded safety connector with ample built-in strain relief.
  • Peel back pouch that allows for safe and easy transfer to the sterile field.

Specifications

Rhythmlink Disposable Extended Monopolar Stimulating Probe Specifications

  • Materials:
    • Probe: Stainless steel.
    • Insulation: Kynar.
    • Leadwire: Tinned copper with PVC jacket.
    • Connector: DIN 42 802.
    • Handle: ABS plastic.
    • Protective Cover: PVC, radio-opaque blue.
    • Sterilized: Yes - ethylene oxide.
  • Environment:
    • Latex-free electrode.
    • PVC-free packaging.
  • Packaging:
    • Pouch, Transparent Layer: Polyethylene.
    • Pouch: Tyvek.
    • Pouch Size: 405 mm x 70 mm.
    • Box: Paperboard.

Package Quantities

Rhythmlink Disposable Extended Monopolar Stimulating Probe Package Quantities

Product Number Probe Length Probe Diameter Tip Diameter Lead Length Quantity
#RLMSP101-2.5 160 mm 3.5 mm 1.6 mm 2.5 m 1
#RLMSP100-2.5 160 mm 3.5 mm 1.6 mm 2.5 m 5
Leadwire Color: Brown

Frequently asked questions

Does the probe include critical safety features?

Yes, this disposable monopolar stimulating probe is engineered with critical safety and design features for precision nerve identification, especially during deep surgical procedures:

  • Non-Traumatic Tip Design: The probe features a precise, 1.6 mm semispherical tip engineered to be non-traumatic, which minimizes potential tissue damage during delicate nerve localization.
  • Extended Insulation: The long 160 mm stainless steel shaft is fully insulated with Kynar, maintaining necessary electrical isolation for safety in deep surgical approaches.
  • Secure Connection: It utilizes a molded safety connector (DIN 42 802 standard) that includes built-in strain relief, ensuring a stable and secure connection to the monitoring system.
  • Sterile and Safe Materials: The product is supplied sterile (via Ethylene Oxide), is completely latex-free, and the primary packaging is PVC-free.
  • Enhanced Visibility: The leadwire includes a radio-opaque blue PVC protective cover.
Is the Rhythmlink Disposable Extended Monopolar Stimulating Probe sterile?

Yes, the probe is supplied sterile and has been sterilized with ethylene oxide.

Does the Rhythmlink Disposable Extended Monopolar Stimulating Probe contain latex?

No, the Rhythmlink Disposable Extended Monopolar Stimulating Probe is latex-free.

Is the extended probe safe for deep surgical use?

Yes, the Rhythmlink Disposable Extended Monopolar Stimulating Probe is specifically designed to provide safe and precise nerve identification in deep surgical fields, making it ideal for procedures like XLIF and other minimally invasive spinal approaches.

The design incorporates several features to ensure safety and enhanced access:

  • Extended Reach: The probe features a long 160 mm insulated shaft which is longer than traditional probes, allowing it to easily accommodate deep anatomical structures.
  • Non-Traumatic Tip: It utilizes a 1.6 mm semispherical, non-traumatic tip engineered to minimize tissue damage while safely locating and stimulating nerves (e.g., the genitofemoral nerve).
  • High-Quality Materials: The stainless steel probe is insulated with Kynar, ensuring accurate and localized nerve stimulation throughout the shaft length.
  • Sterile & Reliable: The probe is supplied sterile (via Ethylene Oxide) and includes a molded safety connector (DIN 42 802) with built-in strain relief for reliable use in the sterile field.

This instrument is also versatile for general spinal/peripheral nerve identification and pedicle hole/screw testing.

What are the primary applications for this probe?

This disposable extended monopolar stimulating probe is designed for safe and precise nerve identification during complex procedures. Its 160 mm insulated shaft and non-traumatic semispherical 1.6 mm tip make it ideal for deep access and safety assurance in:

  • Spinal Nerve Identification: Crucial for minimally invasive spine surgery (MISS), including lateral spinal approaches such as Extreme Lateral Interbody Fusion (XLIF).
  • Peripheral Nerve Procedures: Used for accurate localization of peripheral nerves, including the genitofemoral nerve.
  • Intraoperative Safety Checks: Recommended for testing pedicle holes and screws to confirm integrity and positioning during spinal instrumentation placement.
Is the packaging of the Rhythmlink Disposable Extended Monopolar Stimulating Probe PVC-free?

Yes, the product has PVC-free packaging.

Is this stimulating probe versatile for various procedures?

Yes, the Rhythmlink Disposable Extended Monopolar Stimulating Probe is designed for precise intraoperative nerve identification and versatility in critical surgical environments. Its 160 mm extended, insulated shaft accommodates deeper surgical approaches.

Primary applications include:

  • Spinal Nerve Identification: Essential during minimally invasive spinal surgeries, particularly lateral approaches like XLIF (Extreme Lateral Interbody Fusion).
  • Peripheral Nerve Identification: Used to safely locate structures such as the genitofemoral nerve.
  • Hardware Integrity Testing: Suitable for confirming the correct placement and integrity of pedicle holes and screws.

It features a non-traumatic 1.6 mm semispherical tip to ensure safe stimulation testing.

What is the benefit of the extended 160 mm shaft?

The Rhythmlink probe features an extended 160 mm insulated shaft, making it longer than traditional monopolar probes. This design provides critical benefits for complex procedures:

  • It enables access to deeper structures during surgery.
  • It is specifically designed to facilitate navigation during lateral spinal approaches (XLIF) and other minimally invasive spinal surgeries.
  • The extended length promotes safer and more precise nerve identification in areas standard probes may not reach.
What material is the probe made of?

The probe is made of stainless steel with Kynar insulation.

What is the length of the probe's lead wire?

The lead wire has a length of 2.5 meters.