Regular price$8,865.00 Sale price$6,561.83
Select a Voltage
Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Burton CoolSpot II Examination Light - Single Fastrac Mount provides a range of movement that can't be found with stationary ceiling mounts. The mounted spotlight can be maneuvered easily for the most ideal positions for care providers.

Warranty: 5 Years - Parts and Labor

The Burton CoolSpot II Examination Light - Single Fastrac Mount spans 6 feet in length, offering a variety of positions and reach for the spotlight. In addition to the width that the light can travel, the light is posted on a 30 inch drop tube and two arms measuring 18 inches and 19.5 inches. The light is also equipped with a SteriHandle grip, which is also easily interchangeable for sterile procedures. The bi-level dimmer allows users to adjust the light intensity as needed, and remains cool for patient comfort.

The Single Fastrac Mount showcases a level of mobility that can't be found with other ceiling mounts. Not only is the light mounted to a rolling track, but also maintains the two-arm, two-hinge design for a variety of adjustable positions. It's an ideal spotlight for any hospital and clinical setting, especially where space may be limited.

The Burton CoolSpot II Examination Light - Single Fastrac Mount ships in 3 packages:

  • Head: 12.5 lb / 36" x 14" x 8".
  • Track: 58 lb / 76" x 13" x 9".
  • Trolley: 34 lb / 33" x 29" x 10".

Features

Burton CoolSpot II Examination Light - Single Fastrac Mount Features

  • Average 600 hours of bulb life.
  • Friction knob adjusts tension for no-drift arm.
  • Low-maintenance design and housing.
  • Mounts meet California Seismic Codes.
  • Comes standard with 120 V, with 230 / 240 V and 100 V available.

Specifications

Burton CoolSpot II Examination Light - Single Fastrac Mount Specifications

  • Weight: 104.5 lb (47.4 kg).
  • Drop Tube Length: 30" (76.20 cm).
  • Recommended Ceiling Height: Min. 8 ft (2.44 m) / Max. 10 ft (3.05 m).
  • Light Source: Halogen bulb - 150 watts.
  • Variable Spot Size: 2" - 10" (5 cm - 25 cm).
  • Illuminance: 60,000 lux (5,574 footcandles).
  • Light Color Temperature: 4,300 Kelvin.
  • Color Rendering Index: 94.
  • Number of Bulbs: 1.
  • Bulb Life: 600 hours.
  • Power: 160 Watts.
  • Certifications / Approvals: UL 60601-1, EN 60601-1-2, IEC 60601-2-41 and CAN/CSA C22.2 NO. 601.1 M90.
  • FDA Classification: FDA Class I, Major Surgery Light.

Configurations

Burton CoolSpot II Examination Light - Single Fastrac Mount Configurations

  • #CS316ST: 120 V - For use in the U.S.
  • #CS325ST: 230 / 240 V - For use in Europe.
  • #CS315ST: 100 V - For use in Japan.

Burton CoolSpot II Examination Light - Single Fastrac Mount Accessories

The Burton CoolSpot II Examination Light - Single Fastrac Mount is commonly purchased with:

  • CoolSpot II Replacement Bulbs (4 / Box).
  • CoolSpot II Replacement Handle.
  • Light Handle Covers, Sterile (25 / Box).

Frequently asked questions

How great is the system's mobility?
<p>The positioning mobility of the CoolSpot II is considered <strong>exceptional</strong> and unmatched by conventional stationary ceiling mounts. This flexibility is achieved through a sophisticated, multi-component system designed for maximum range and precision:</p>

<ul>
<li><strong>Single Fastrac Rolling Track:</strong> This unique track allows the entire light assembly to traverse along the ceiling, providing a total reach or travel span of <strong>up to 6 feet</strong>.</li>
<li><strong>Articulated Dual-Arm Design:</strong> The configuration uses two hinged arms (18 inches and 19.5 inches) for effortless and precise maneuvering of the light head.</li>
<li><strong>No-Drift Stability:</strong> A friction knob is included to adjust arm tension, guaranteeing the light remains stable and maintains its exact position once set.</li>
</ul>
Is the light intensity and spot size adjustable?
<p>Yes, the Burton CoolSpot II is engineered for precise control, allowing you to easily customize both the brightness and the focus area:</p>

<ul>
<li><strong>Intensity Control:</strong> The light features a <strong>bi-level dimmer</strong> for convenient adjustment of illumination, which helps maximize patient comfort while ensuring clear visibility for clinical procedures.</li>
<li><strong>Variable Spot Size:</strong> The focal area is fully adjustable, ranging from a focused beam of <strong>2 inches up to 10 inches</strong> (5 cm to 25 cm) in diameter.</li>
</ul>

<p>This high degree of control supports the light’s excellent overall performance, which delivers <strong>60,000 lux</strong> illumination and boasts a high Color Rendering Index (CRI) of 94.</p>
Does the light remain cool during use?
<p>Yes, the Burton CoolSpot II is specifically engineered for patient comfort. It utilizes a <strong>cool-running halogen light source</strong> to ensure the light head and housing remain cool, even during prolonged examination or minor procedures. This low-heat operation is a crucial feature for maximizing patient comfort in clinical settings.</p>
Is the SteriHandle grip easily interchangeable?
<p>Yes, the Burton CoolSpot II is specifically designed for hygienic use. It is equipped with an <strong>easily interchangeable SteriHandle grip</strong> to ensure that sterile procedures can be safely maintained during clinical use.</p>
Is a powerful 150-watt halogen bulb used?
<p>Yes, the Burton CoolSpot II utilizes a <strong>150-watt halogen bulb</strong> that provides high-intensity illumination suitable for clinical and major surgical procedures, classifying it as an FDA Class I Major Surgery Light.</p>

<p>This light source is optimized for accurate clinical assessment, offering:</p>

<ul>
<li><strong>High Output:</strong> Delivers a powerful <strong>60,000 lux</strong> of light.</li>
<li><strong>Color Accuracy:</strong> Features an excellent Color Rendering Index (CRI) of <strong>94</strong> and a color temperature of <strong>4,300 Kelvin</strong>, essential for distinguishing tissue colors accurately.</li>
<li><strong>Adjustability:</strong> Includes a <strong>bi-level dimmer</strong> for intensity control and a variable spot size ranging from 2 inches to 10 inches.</li>
<li><strong>Cool Design:</strong> The fixture is designed to maintain cool operation, ensuring patient comfort.</li>
<li><strong>Bulb Life:</strong> The standard halogen bulb has an average life expectancy of <strong>600 hours</strong>.</li>
</ul>
Does the light offer high brightness and color accuracy?
<p>Yes, the Burton CoolSpot II provides <strong>high-intensity, accurate illumination</strong> suitable for major clinical procedures, classified as an <strong>FDA Class I, Major Surgery Light</strong>.</p>

<p>Key illumination specifications include:</p>

<ul>
<li><strong>High Brightness:</strong> Delivers powerful illumination of <strong>60,000 lux</strong> (5,574 footcandles).</li>
<li><strong>Color Accuracy:</strong> Features an excellent <strong>Color Rendering Index (CRI) of 94</strong> and a color temperature of <strong>4,300 Kelvin</strong>, ensuring accurate visualization and tissue differentiation.</li>
</ul>

<p>The light source is a 150-watt Halogen bulb. The system offers precise control over the light field:</p>

<ul>
<li><strong>Spot Size:</strong> Variable, adjustable from 2 inches up to 10 inches (5 cm - 25 cm).</li>
<li><strong>Intensity:</strong> Controlled via a convenient <strong>bi-level dimmer</strong>.</li>
</ul>
Does the light offer a professional color temperature?
<p>Yes, the Burton CoolSpot II Examination Light provides a <strong>light color temperature of 4,300 Kelvin</strong>. This ensures high-quality illumination suitable for detailed medical examinations.</p>
What is the average bulb lifespan?
<p>The examination light utilizes a 150-watt Halogen bulb, which provides an average lifespan of <strong>600 hours</strong>. This ensures reliable, high-intensity illumination for extended use in clinical settings.</p>