The Nicolet EDX EMG/NCS/EP/IOM System includes the EDX Base Unit, choice of amplifier, Dell E5540 laptop (Intel i5 processor, 500 GB Hard Drive, 8 GB RAM) loaded with Nicolet Viking and Teca Synergy Version 22 EMG software on a Windows 11 operating system, control panel, electrical stimulator probe, and interconnecting cables (please find variant-specific included accessories below in the Configurations section).

Warranty: 90 Days - Parts and Labor.

The EDX EMG/NCS/EP/IOM System is the industry-leading electrodiagnostic system used to measure nerve and muscle function and can also provide intraoperative monitoring for the operating room. The Nicolet EDX is powered by Viking or Synergy software with a variety of study/exam options providing fast and efficient workflow. This hardware/software platform combines a familiar clinical workflow and user interface to provide innovative features developed to reduce artifacts, reduce operator errors, and improve ease of use. Viking software not only provides exceptional quality electrodiagnostic studies for routine examinations, but also for challenging cases in difficult clinical environments, even including in the operating room for IOM studies.

Features

Nicolet EDX EMG/NCS/EP/IOM System Features

  • EDX Base Unit:
    • Powerful Digital Signal Processor provides advanced signal processing functionality.
    • Connections for footswitch (single or triple), patient response unit, control panel, LED goggles, audio transducers, and reflex hammer.
    • Eight channel availability to external acquisition equipment for online analysis through the analog out connector.
  • Electrical Stimulator Probe:
    • Small, lightweight, and ergonomically designed for maximum comfort.
    • Coiled cable extends reach to the patient without touching the floor.
  • 2-Channel Amplifier (option):
    • Optimized for basic EMG/NCS/EP.
    • 2 non-switched amplifier channels.
    • Stimulus artifact suppression.
  • 2+6-Channel Amplifier (option):
    • Optimized for advanced EMG/NCS/EP testing.
    • 2 non-switched and 6 switched channels.
    • Configuration options include 3, 5, 7, or 8 simultaneously active channels.
    • Stimulus artifact suppression.
  • 16-Channel Clinical EP/IOM Amplifier (option):
    • Multiple data type acquisition including EMG, NCS, EP, and IOM.
    • Increased functionality with IOM capability.
    • 16 user selectable differential channels.
    • Multiple EP applications.
  • Viking or Synergy Software: Innovative features developed to reduce artifacts, minimize operator errors, and improve ease of use.
    • Efficient workflow from patient entry to report.
    • Automatic markers, measurement tables, and data storage.
    • Flexible data control with roll back, roll forward, averaging, auto store, and signal enhancer.
    • Automation of test procedures: short and long exercise tests.
    • Online reports for immediate access to all results.
    • Customizable reports.
  • Networking and IT Features:
    • Natus HL7 Solutions: Natus Neuro equipment has been successfully integrated into Epic, Meditech, Cerner, McKesson, and other Hospital Electronic Medical Records Systems.
    • Remote Access: Natus provides the most powerful infrastructure to facilitate collaboration with offsite colleagues through remote access and review.
    • HIPAA Compliance: Security can be integrated with Microsoft Active Directory as well as with Microsoft Bitlocker encryption.
    • Basic EMR Transfer: Simplify the process of transferring finalized PDF reports to your EMR with the Basic EMR Transfer feature.
  • Advanced technology amplifiers with high resolution signals.
  • Two amplifier options provide basic or advanced EMG/NCS/EP testing.
  • Comfortable, ergonomic electrical stimulator probes.
  • Two trustworthy user interfaces: Viking or Synergy.
  • Integrated SQL database with networked access and data review.
  • HL7 Gateway and advanced connectivity.
  • Citrix compatibility providing remote access from anywhere.

Specifications

Nicolet EDX EMG/NCS/EP/IOM System Specifications

  • Dimensions (D x W x H):
    • Nicolet EDX Base Unit: 3.4" x 13.5" x 14" (8.6 cm x 34.3 cm x 35.6 cm).
    • AT2 2-Channel Amplifier: 1" x 6" x 6.5" (2.5 cm x 15.2 cm x 16.5 cm).
    • AT2+6 8-Channel Amplifier: 1.5" x 8" x 10.3" (4 cm x 20.3 cm x 26 cm).
    • ECR16 16-Channel Amplifier: 1.6" x 8.25" x 12.5" (4 cm x 20.9 cm x 31.7 cm).
    • Viking / Synergy Control Panel: 2" x 5" x 8" (5 cm x 13 cm x 20 cm).
    • USB Control Panel: 1.75" x 5" x 6.75" (4.4 cm x 12.7 cm x 17.1 cm).
    • Clinical Head Box (HB-6) or OR Head Box (HB-7): 0.9" x 4.25" x 6" (2.3 cm x 11 cm x 15 cm).
    • Comfort Probe RS10: 1.25" x 1.5" x 7" (3.2 cm x 4 cm x 18 cm).
  • Weight:
    • Nicolet EDX Base Unit: 8 lb (3.5 kg).
    • AT2 2-Channel Amplifier: 1 lb (0.5 kg).
    • AT2+6 8-Channel Amplifier: 1.6 lb (0.7 kg).
    • ECR16 16-Channel Amplifier: 2.6 lb (1.18 kg).
    • Viking / Synergy Control Panel: 1.25 lb (0.6 kg).
    • USB Control Panel: 0.8 lb (0.36 kg).
    • Clinical Head Box (HB-6) or OR Head Box (HB-7): 0.6 lb (0.3 kg).
    • Comfort Probe RS10: 0.25 lb (0.11 kg).

Configurations

Nicolet EDX EMG/NCS/EP/IOM System Configurations

SKU Configuration Unique Hardware Included
#MFI-NTS-SYNERGY-EDX-8CH-EMG Synergy 8 Channel 2+6-Channel Amplifier, Synergy Version 22 EMG software, and Synergy control panel
#MFI-NTS-NICOLET-EDX-2CH-EMG Nicolet 2 Channel 2-Channel Amplifier, Viking Version 22 EMG software, and Nicolet Viking control panel
#MFI-NTS-NICOLET-EDX-8CH-EMG Nicolet 8 Channel 2+6-Channel Amplifier, Viking Version 22 EMG software, Nicolet Viking control panel, and EP (Electrophysiology) testing
#MFI-NTS-NICOLET-EDX-16CH-IOM Nicolet 16 Channel EP/IOM 16-Channel Clinical EP/IOM Amplifier, HB-1 (headbox 1), HB-2 (headbox 2), MC-4 mini controller, SP-1 (simulation pod 1), and SP-2 (simulation pod 2)

Accessories

Nicolet EDX EMG/NCS/EP/IOM System Accessories

The following accessories are compatible and commonly purchased with the Nicolet EDX EMG/NCS/EP/IOM System:

  • Equipment:
    • #MFI-NCL-CART-WHT: Natus Nicolet Viasys EMG/EEG/IOM Cart.
    • Natus Viking Synergy EMG Computer:
      • #MFI-NTS-EMG-LPT: Laptop.
      • #MFI-NTS-EMG-DESK: Desktop.
    • Nicolet Amplifier Arm.
    • Nicolet Foot Switch.
    • Nicolet Travel Case.
    • Isolation Transformer.
  • Supplies (additional brands and options available):
    • 3M Transpore Surgical Tape.
    • #MFI-GROUND-ELECTRODE: MFI Medical Reusable EMG Ground Electrode.
    • #MFI-BAR-ELECTRODE: MFI Medical Bar EMG Electrode.
    • #MFI-RING-ELECTRODES: MFI Medical Ring EMG Electrodes.
    • #MFI-CDW-DISC-ELECTRODES: MFI Medical Paired EMG Disc Electrodes.
    • Parker Spectra 360 Electrode Gel.
    • Technomed Disposable Adhesive EMG 4-Disk Surface Electrodes.
    • Technomed Disposable Monopolar EMG Needle Electrode.
  • Evoked Potentials Accessories (only compatible with the 8 Channel and 16 Channel configurations):
    • #AMHS-1: Ambco Audiometric Headset.
    • #MFI-VEP-LED-M: VEP LED Monitor.
    • #MFI-NCL-2015-Visual-Stim: Nicolet 2015 Visual Stimulator.
    • Shielded Headphones.
    • LED Goggles.

Frequently asked questions

What core electrodiagnostic studies can it perform?

The Nicolet EDX System is a versatile and comprehensive platform designed to support a full suite of electrodiagnostic studies, suitable for routine clinical exams and advanced surgical monitoring.

It offers four primary core capabilities:

  • Electromyography (EMG): Used for assessing the health of muscles and the nerve cells that control them.
  • Nerve Conduction Studies (NCS): Measures the speed and strength of signals traveling through motor and sensory nerves.
  • Evoked Potentials (EP): Tests the electrical activity of the brain in response to specific external stimulation (visual, auditory, or sensory).
  • Intraoperative Monitoring (IOM): Provides crucial real-time feedback on the nervous system during surgery, especially when using the advanced 16-channel amplifier configuration.
What amplifier configurations are available?

The Nicolet EDX System offers several amplifier configurations to suit various clinical requirements, from routine diagnostics to advanced intraoperative monitoring (IOM). Available options include:

  • Synergy 8 Channel: This configuration includes a 2+6-Channel Amplifier and Synergy Version 22 EMG software.
  • Nicolet 2 Channel: Features a 2-Channel Amplifier and Viking Version 22 EMG software.
  • Nicolet 8 Channel: Equipped with a 2+6-Channel Amplifier, Viking Version 22 EMG software, and EP testing capability.
  • Nicolet 16 Channel EP/IOM: Designed for comprehensive EP and demanding IOM applications, this option includes a 16-Channel Clinical EP/IOM Amplifier, HB-1, HB-2, MC-4 mini controller, SP-1, and SP-2.
Does the system offer robust EMR integration?

Yes, the Nicolet EDX system is designed for robust IT integration to streamline clinical workflow and data management.

Key integration features include:

  • EMR Compatibility: The system utilizes Natus HL7 Solutions for comprehensive integration with major Electronic Medical Records (EMR) systems, including Epic, Meditech, Cerner, and McKesson.
  • Data Management: It features an integrated SQL database that allows for networked access and efficient data review across the clinical environment.
  • Secure Connectivity: Support for Citrix compatibility facilitates secure remote access for clinicians, enabling offsite data review and collaboration. The system is also ready for HIPAA compliance integration with Microsoft Active Directory/Bitlocker.
Where is the Nicolet EDX system typically used?

The Nicolet EDX system is an industry-leading and highly versatile electrodiagnostic platform suitable for a wide range of clinical settings, supporting routine exams to complex monitoring procedures. It is optimally used in the following environments:

  • Diagnostic Neurology Centers & Clinics: Primary setting for performing comprehensive nerve and muscle function assessments, including Electromyography (EMG), Nerve Conduction Studies (NCS), and Evoked Potentials (EP) studies.
  • Operating Rooms (ORs): When configured with higher channel options (like the 16-Channel configuration), the system provides essential, real-time Intraoperative Monitoring (IOM) capabilities during surgical procedures.
  • High-Volume Settings: The integrated Viking or Synergy software features workflow optimizations designed to streamline patient data, reduce operator errors, and enhance efficiency in busy clinical environments.
Is the Nicolet EDX EMG/NCS/EP/IOM System new or refurbished?

The Nicolet EDX EMG/NCS/EP/IOM System is a certified refurbished product.

How does the powerful system software optimize workflow?

The Nicolet EDX system significantly optimizes clinical workflow using the Nicolet Viking or Teca Synergy Version 22 EMG software, which is designed for efficiency and diagnostic accuracy.

Key features that streamline operation and data management include:

  • Enhanced Signal Integrity: The software utilizes the EDX Base Unit’s Digital Signal Processor (DSP) to provide advanced signal processing functionalities, including features for artifact reduction and flexible data control (such as roll back, averaging, and signal enhancer).
  • Automation of Procedures: Efficiency is maximized through the use of automatic markers, measurement tables, and the automation of test procedures, which helps reduce operator error and time spent on data collection.
  • Seamless EMR Integration: The system supports Natus HL7 Solutions for comprehensive integration with major Electronic Medical Records (EMR) platforms, including Epic, Meditech, Cerner, and McKesson. It also features remote access capability via Citrix compatibility.
What components are included in the Nicolet EDX system?

The Nicolet EDX System is a Certified Refurbished solution designed for comprehensive electrodiagnostic testing. The base package includes:

  • EDX Base Unit: The core unit featuring a powerful Digital Signal Processor for advanced signal processing.
  • Amplifier: Available in configurations like 2-channel, 8-channel (with EP testing capability), or 16-channel Clinical EP/IOM Amplifier for advanced intraoperative monitoring.
  • Dell E5540 Laptop: Equipped with an Intel i5 processor, 8 GB RAM, and a 500 GB HDD, pre-loaded with Windows 11.
  • Software: Either Nicolet Viking Version 22 or Synergy Version 22 EMG software, loaded onto the laptop.
  • Control Panel: Specific to the chosen software (Nicolet Viking or Synergy).
  • Electrical Stimulator Probe: A small, lightweight, and ergonomically designed probe with a coiled cable.
  • Interconnecting Cables: All necessary cables to connect the system components.

Specific hardware and software vary based on the selected configuration. The system also comes with a 90-day parts and labor warranty.

Is the Nicolet EDX a comprehensive system?

Yes, the Nicolet EDX is recognized as a comprehensive, industry-leading electrodiagnostic platform (Certified Refurbished).

It supports a versatile range of studies, including:

  • EMG (Electromyography)
  • NCS (Nerve Conduction Studies)
  • EP (Evoked Potentials)
  • IOM (Intraoperative Monitoring) capabilities

Performance and Software

The system utilizes a Powerful Digital Signal Processor (DSP) in the EDX Base Unit for advanced signal processing. It runs on Windows 11 and includes either the Nicolet Viking or Synergy Version 22 EMG software, which offers tools to minimize artifacts and streamline test procedures.

Integration

For clinical workflow efficiency, the EDX system includes robust connectivity features such as:

  • HL7 integration for connecting with major EMR systems (e.g., Epic, Cerner).
  • Remote access infrastructure via Citrix compatibility.

The system is highly configurable, available in 2-Channel, 8-Channel, and 16-Channel amplifier options to match specific testing needs.

Is advanced signal processing included?

Yes, the Nicolet EDX system is specifically engineered for advanced signal processing to ensure accurate and efficient testing. The system’s capabilities are driven by two main features:

  1. Digital Signal Processor (DSP): The core EDX Base Unit features a dedicated DSP for high-quality signal acquisition and complex electrodiagnostic processing.
  2. Artifact Suppression: The Viking or Synergy software utilizes innovative tools to minimize artifacts and reduce operational errors, significantly improving workflow. Additionally, the 2-Channel and 2+6-Channel amplifiers include a dedicated Stimulus Artifact Suppression feature.
What electrodiagnostic software is included?

The Nicolet EDX system includes either the Nicolet Viking Version 22 EMG software or the Synergy Version 22 EMG software, depending on the configuration selected. Both software packages are pre-loaded on the included Dell E5540 laptop and run on the Windows 11 operating system.The software is designed to enhance workflow efficiency by offering tools for artifact reduction, error minimization, and automation of testing procedures.