- Condition: Factory New
- Weight: 0.95 lb
- Endo Close Trocar Site Closure Device, 12/bx
-
Learn more:
- MFR: Medtronic/Minimally Invasive Therapies Group Ships from MFI Medical
- MPN: 173022
- Phone: (800) 633-8766
Frequently asked questions
How many Endo Close™ Trocar Site Closure Devices are included in one package?
One package includes 12 Endo Close™ Trocar Site Closure Devices.
Is the Medtronic Endo Close Trocar Site Closure Device factory new?
Yes, the Medtronic Endo Close Trocar Site Closure Device is factory new, ensuring it arrives in its original, untouched condition.
What is the primary purpose of the Medtronic Endo Close™ Trocar Site Closure Device?
The Medtronic Endo Close™ Trocar Site Closure Device is designed for the efficient and safe closure of trocar sites following minimally invasive surgical procedures.
How does the spring-located blunt stylet mechanism enhance safety?
The Medtronic Endo Close device utilizes an automatic spring-located blunt stylet mechanism specifically designed to enhance safety during penetration of the abdominal wall and peritoneum.
This mechanism works as follows:
- Retraction: The blunt stylet automatically retracts as the needle is advanced through the abdominal wall tissue.
- Advancement: The stylet automatically advances once the peritoneum has been breached.
This specialized action helps ensure controlled and safe passage through tissue layers, streamlining the trocar site closure process.
What suture sizes are recommended for optimal closure with this device?
The recommended suture sizes for optimal closure are USP 2-0 or 0.
Who is the manufacturer of the Medtronic Endo Close™ Trocar Site Closure Device?
The Medtronic Endo Close™ device is manufactured by Medtronic/Minimally Invasive Therapies Group.
How does the automated blunt stylet work?
The Medtronic Endo Close device utilizes an automated, spring-located blunt stylet mechanism designed to facilitate safe and controlled passage during trocar site closure. The mechanism works as follows:<ul><li>The stylet automatically retracts as the needle is pushed through the abdominal wall tissue.</li><li>The stylet then automatically advances once the peritoneum has been breached.</li></ul>This action streamlines the closure process and helps to reduce the risk of inadvertent injury during the procedure.
Does it offer automated stylet advancement?
Yes, the Medtronic Endo Close Trocar Site Closure Device features an automated stylet advancement mechanism. This ensures proper placement once the peritoneum has been penetrated, enhancing precision and safety during the procedure.
What is its primary surgical application?
This device is specifically designed for closing trocar sites after minimally invasive surgical procedures. Its spring-located blunt stylet and automated advancement mechanism facilitate safe and effective tissue penetration and closure.
Does it streamline the closure process?
Yes, the device features an automated spring-located blunt stylet mechanism that enhances safety and streamlines the trocar site closure process. The stylet automatically retracts upon penetrating the abdominal wall and advances once the peritoneum is penetrated, making the procedure more efficient.