Sale price$267.72
Est. Delivery:
<p>Earn%20[points_amount]%20when%20completing%20this%20purchase.</p>

Description

This Maxtec MAX-11i O2 Cell, manufactured by Cables and Sensors, is a compatible replacement for the Maxtec MAX-11i and other oxygen sensors (see below). It is compatible with Drager, Envitec, Maxtec, and Nuova systems.

Note: Can only be shipped within the U.S.

Specifications

Maxtec MAX-11i O2 Cell Specifications

  • Compatible with:
    • Drager Incubators, 18000 High Temp Application.
    • Envitec.
    • Maxtec.
    • Nuova.
  • Equivalent to:
    • Drager: I-8000.
    • Envitec: OOM104.
    • Maxtec: MAX-11i R113P06.
    • Nuova: E-8000.
    • Philips Respironics NeoPAP.
  • G0-080 (Maxtec Equivalent) Specifications:
    • Response Time: Less than 12 seconds.
    • Connector Type: 3 x Gold plated slip-rings.
  • R113P06 (Maxtec) Specifications:
    • Output: 17.0 ± 3.0 mV.
    • Response Time: ≤ 12 seconds.
    • Linearity: Less than 3.0% of full scale.

Configurations

Maxtec MAX-11i O2 Cell Configurations

  • G0-080: MAX-11i Cell Equivalent manufactured by Cables and Sensors.
    • Warranty: 16 Month Shelf Life.
  • R113P06: Maxtec MAX-11i Cell manufactured by Maxtec.
    • Warranty:1 Year Shelf Life.

Frequently asked questions

What systems is the Maxtec MAX-11i Oxygen Cell compatible with?

The Maxtec MAX-11i Oxygen Cell is compatible with several systems, including Drager, Envitec, Maxtec, and Nuova systems. Specifically, it works with Drager Incubators (18000 High Temp Application) and Philips Respironics NeoPAP.

What are the G0-080 and R113P06 sensor differences?

The primary differences between the G0-080 and R113P06 configurations relate to the manufacturer and warranty specifications:

Feature G0-080 (Equivalent) R113P06 (Maxtec Original)
Manufacturer Cables and Sensors Maxtec
Shelf Life Warranty 16 Months 1 Year
Output Standard 17.0 ± 3.0 mV
Linearity Not specified Less than 3.0% of full scale
Connector 3 x Gold plated slip-rings Not specified

Both configurations function as a direct replacement sensor (Factory New) with a rapid response time ($\le 12$ seconds) and are compatible with various medical systems, including Drager, Envitec, Maxtec, Nuova, and Philips Respironics NeoPAP.

Is this oxygen cell broadly compatible?

Yes, the Maxtec MAX-11i Oxygen Cell offers broad system compatibility, making it a versatile replacement FiO2 sensor for numerous medical monitoring systems. It is designed to work with equipment from several major brands.

Key compatibility details include:

  • Compatible Systems: Drager (including 18000 High Temp Incubator applications), Envitec, Maxtec, and Nuova devices.
  • Equivalent Models: It replaces sensors such as the Drager I-8000, Envitec OOM104, Maxtec MAX-11i R113P06, Nuova E-8000, and Philips Respironics NeoPAP.
Does it provide accurate oxygen readings?

Yes, the Maxtec MAX-11i O2 Cell is designed for precise oxygen measurement (FiO2).

When choosing the Maxtec Original (R113P06) configuration, the performance specifications ensure high accuracy:

  • Linearity: Less than 3.0% of full scale.
  • Response Time: $\le 12$ seconds, ensuring rapid measurement.

This factory new sensor serves as a high-quality replacement for various critical care monitoring systems.

Is this a brand new product?

The Maxtec MAX-11i Oxygen Cell is a factory new product, ensuring optimal performance and reliability.

What is the MAX-11i O2 Cell's response time?

The MAX-11i O2 Cell is designed for rapid measurement of oxygen concentration (FiO2).

The specified response time for both configurations (the G0-080 equivalent and the original R113P06 Maxtec part) is 12 seconds or less ($\le 12$ seconds).

Does the sensor feature reliable gold-plated slip rings?

Yes, reliable connectivity is a top selling point for the MAX-11i Oxygen Cell, designed to ensure robust electrical connection and minimize signal interruption. This is achieved through the use of high-quality components.

Specifically, the G0-080 equivalent configuration features:

  • 3 gold-plated slip-rings
What is the output voltage of the Maxtec MAX-11i Oxygen Cell (R113P06)?

The output voltage specification for the R113P06 equivalent configuration of the Maxtec MAX-11i Oxygen Cell is 17.0 ± 3.0 mV. This output level is crucial for ensuring accurate oxygen level measurements in compatible monitoring systems.

Are specific safety documents available?

Yes, a Safety Data Sheet for Maxtec KOH Oxygen Sensors and a Specifications Sheet for the MAX-11i Oxygen Cell are available via external links for detailed information.