Sale price$399.93
Est. Delivery:
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+

Description

The Masimo LNCS Trauma Sensor (#2411 / 20 per Box) is a comfortable, durable, and reliable single patient sensor. The integrated cable means that the sensor is even simpler to set up while remaining fully disposable and offers improved moisture resistance. It is compatible with all Masimo SET/Nellcor DB9 9-pin connects.

Warranty: Until Use, Within 6 Months of Shipment.

The replacement SofTouch Wrap (#2309 / Box of 10) is sold separately.

Features

Masimo LNCS Trauma Sensor Features

  • Patient Size: Adult (> 30 kg).
  • Cable Length: 3'.
  • Durable adhesive tape.
  • Easy to move and reapply.
  • Improved moisture resistance.
  • Long-lasting sensor.
  • Recessed detector reduces interference.
  • EM interference resistant.
  • Provides the most rapid, high-resolution, accurate SpO2 and PR measurements during trauma situations.
  • Single-patient use sensors lower risk of cross-contamination.
  • Stays attached in high-motion environments.
  • Lower pressure on monitoring site, reduces risk of pressure necrosis.
  • Sterilizable.
  • Not made with natural rubber latex.

Frequently asked questions

Is the Masimo Trauma SpO2 Sensor for single-patient use?

Yes, the Masimo Trauma SpO2 Sensor is designed for single-patient use. This design is a key feature to enhance patient safety by minimizing the risk of cross-contamination in clinical settings.

What monitoring equipment is compatible with this sensor?

This Masimo LNCS Trauma Sensor is compatible with patient monitoring equipment that uses Masimo SET or Nellcor DB9 9-pin connection systems. The sensor features a 3-foot integrated cable that terminates in a yellow connector designed specifically for these interfaces.

How many sensors are included in each box?

Each box of the Masimo Trauma SpO2 Sensor contains 20 sensors. These sensors are designed for single-patient use, ensuring enhanced patient safety and minimizing cross-contamination risks.

Is this sensor designed for adult use?

Yes, this Masimo LNCS Trauma Sensor is intended for adult patient monitoring. As a single-patient use sensor, it is engineered to be highly durable and reliable, ensuring rapid, accurate SpO2 and Pulse Rate (PR) measurements. It features an integrated cable for simplified setup and enhanced moisture resistance.

What is the length of the integrated cable?

The Masimo LNCS Trauma Sensor features an integrated cable that measures 3 feet (3’) in length.

This integrated design is intended to simplify the setup process and improve moisture resistance, ensuring reliable performance, especially in high-motion trauma environments.

Does the sensor stay attached well, even with patient movement?

Yes, the Masimo Trauma SpO2 Sensor features durable adhesive tape that keeps it securely attached, even in high-motion environments. It is also designed to be easily moved and reapplied if needed.

Does the sensor have high moisture resistance?

Yes, the Masimo LNCS Trauma Sensor is designed with improved moisture resistance. This feature, combined with its durable adhesive tape, ensures the sensor stays reliably attached and maintains accurate readings even in high-motion or demanding clinical environments where moisture may be present.

Does this sensor provide highly accurate SpO2 and pulse rate readings?

Yes, the Masimo LNCS Trauma Sensor is specifically engineered to provide the most rapid, high-resolution, and accurate SpO2 and Pulse Rate (PR) measurements, which is critical during trauma situations.

Its design features ensure superior reliability in challenging environments:

  • It utilizes Masimo Signal Extraction Technology (SET) for optimal performance.
  • The sensor features a recessed detector to minimize external interference.
  • It is built with improved moisture resistance and resists electromagnetic (EM) interference.
  • The durable adhesive tape is designed to stay attached even in high-motion environments, maintaining continuous, accurate readings.
Is the trauma sensor designed for patient comfort?

Yes, the Masimo LNCS Trauma Sensor is meticulously designed to prioritize patient safety and comfort, even during high-motion situations. Key features include: * Lower Pressure Design: The sensor applies lower pressure to the monitoring site, which actively helps reduce the risk of pressure necrosis. * Durable, Reusable Adhesive: It features durable adhesive tape that remains securely attached in dynamic environments but is easy to move and reapply. * Latex-Free Material: The sensor is not manufactured using natural rubber latex, minimizing potential irritations.

Does the sensor have an integrated cable?

The Masimo Trauma SpO2 Sensor is designed with an integrated cable for a simpler setup process. This feature also contributes to its improved moisture resistance and overall reliability.