Sale price$218.28
Select a Cable Length

Special Order Item

Est. Delivery: 
<p>Earn%20[points_amount]%20when%20completing%20this%20purchase.</p>

Description

The Masimo LNCS DBI Reusable SpO2 Sensor is an adult, soft sensor designed for continuous non-invasive monitoring and spot-checking of SpO2 (functional oxygen saturation of arterial hemoglobin) and pulse rate, for use with adult patients during no motion conditions, and for patients who are well or poorly perfused in hospitals, hospital-type facilities, mobile, and home environments.

Warranty: 6 Months - Free of Defects in Materials and Workmanship.

The DBI Direct Connect Sensor is designed for use only with instruments containing or licensed to use Masimo SET technology or Masimo Rainbow SET technology.

Features

Masimo LNCS DBI Reusable SpO2 Sensor Features

  • Latex-free.
  • Non-Sterile.
  • Fast and easy to apply.
  • Comfortable fit.
  • Designed as a reusable partner product for LNCS adhesive sensors.
  • Covered cable connector design improves moisture resistance.
  • Durable design resists tearing, cracking, and crushing.
  • Designed for accurate monitoring during electrosurgical interference and intense ambient light.
  • Accurately performs under conditions of motion and low perfusion.
  • Reports true alarms while minimizing false alarms.
  • Connects to all Masimo SET oximeters via LNC patient cable.

Specifications

Masimo LNCS DBI Reusable SpO2 Sensor Specifications

  • Adult use (> 30 kg).
  • Application Site: Middle or ring finger (of the non-dominant hand - preferred).
  • Saturation Accuracy, No Motion: +/- 2%.
  • Pulse Rate Accuracy, No Motion: +/- 3 bpm.
  • Low Perfusion Accuracy:
    • Saturation: +/- 2%.
    • Pulse Rate: +/- 3 bpm.

Lengths

Masimo LNCS DBI Reusable SpO2 Sensor Cable Lengths

  • #2651 (DBI-dc3): 3 Feet.
  • #2652 (DBI-dc8): 8 Feet.

Literature

Frequently asked questions

Does this sensor connect to all Masimo SET oximeters?

Yes, this reusable sensor connects directly to all Masimo SET oximeters using the required LNC patient cable.

For full compatibility and operation, the instrument must contain or be licensed to use either:

  • Masimo SET technology
  • Masimo Rainbow SET technology
Is the sensor accurate despite motion or low perfusion?

Yes, this sensor is specifically engineered for accurate performance in challenging environments, including conditions often problematic for standard sensors.

The Masimo LNCS DBI sensor maintains reliability by performing accurately despite:

  • Patient Motion and Low Perfusion: It provides dependable $\text{SpO}_2$ and pulse rate readings even when the patient is moving or experiencing low blood flow.
  • Interference: Accuracy is also maintained during electrosurgical interference and intense ambient light.

The specified measurement accuracy under both no-motion and low perfusion conditions is:

  • $\text{SpO}_2$ Saturation: $\pm 2\%$
  • Pulse Rate: $\pm 3$ bpm

Additionally, the sensor features a highly durable and reusable design that resists tearing, cracking, and crushing, ensuring reliable long-term functionality.

Is the Masimo SpO2 sensor latex-free?

Yes, the Masimo LNCS DBI Reusable SpO2 Sensor is designed to be latex-free.

This material choice is crucial for ensuring patient comfort and safety, especially for individuals with known latex sensitivities.

Key design features of this reusable soft sensor also include:

  • Soft Material Construction: Designed for a comfortable fit and fast, easy application, typically on the middle or ring finger.
  • Durability: The sensor resists tearing, cracking, and crushing.
  • Sterility: The sensor is supplied non-sterile.
Is the sensor provided sterile?

The Masimo LNCS DBI Reusable SpO2 Sensor is supplied as non-sterile.

Since this is a reusable sensor, appropriate cleaning and disinfection protocols must be strictly followed between each patient use to maintain hygiene and ensure the sensor’s long-term performance.

Is this reusable sensor comfortably designed for adults?

Yes, this Masimo LNCS DBI Reusable SpO2 Sensor is designed specifically for adult patients weighing over 30 kg.

It prioritizes patient comfort and safety:

  • Comfortable Fit: The soft sensor is designed for a fast and comfortable application.
  • Material Safety: It is completely latex-free.
  • Monitoring Use: It facilitates both continuous non-invasive monitoring and spot-checking of SpO2 and Pulse Rate.

For optimal use, the sensor should be applied to the middle or ring finger (non-dominant hand preferred).

Is the SpO2 sensor highly accurate?

Yes, the Masimo LNCS DBI Reusable SpO2 Sensor is engineered for high accuracy and reliable monitoring, even under challenging conditions. It maintains accuracy despite:

  • Motion
  • Low perfusion
  • Electrosurgical interference
  • Intense ambient light

This design minimizes false alarms while ensuring accurate readings. Key accuracy specifications:

Condition SpO2 Accuracy Pulse Rate Accuracy
No Motion ±2% ±3 bpm
Low Perfusion ±2% ±3 bpm
Does the sensor offer different cable lengths?

Yes, the Masimo LNCS DBI Reusable SpO2 Sensor is offered in two cable lengths, allowing for flexibility and adaptability in various monitoring settings, whether at the bedside or during mobile use.

The available cable length options are:

  • 3 Feet
  • 8 Feet
Is this SpO2 sensor highly durable?

Yes, the Masimo LNCS DBI Reusable SpO2 Sensor is engineered for exceptional durability and reliable, long-term performance in demanding clinical and home environments. It serves as a cost-effective, reusable partner product to LNCS adhesive sensors.

Key aspects ensuring its robustness include:

  • Physical Protection: The sensor features a durable construction that actively resists common physical damage, including tearing, cracking, and crushing.
  • Moisture Resistance: It incorporates a covered cable connector design which significantly improves resistance against moisture ingress.
  • Performance Resilience: The sensor is designed to maintain measurement accuracy even during challenging conditions such as patient motion, low perfusion, electrosurgical interference, and intense ambient light.
Is the SpO2 sensor reusable?

Yes, the Masimo LNCS DBI is explicitly a reusable SpO2 sensor. It is designed to be a durable, cost-effective solution for continuous non-invasive monitoring and spot-checking of SpO2 and pulse rate on adult patients.

Key features supporting its reusability and durability include:

  • Durable Design: Boasts a durable construction that resists tearing, cracking, and crushing.
  • Moisture Protection: Features a covered cable connector design to improve moisture resistance.
  • Intended Use: Serves as a reusable counterpart to disposable LNCS adhesive sensors.
Where should the SpO2 sensor be applied?

The LNCS DBI Reusable SpO2 Sensor is designed for use with adult patients (weighing over 30 kg). The preferred application site is the middle or ring finger of the patient’s non-dominant hand.