Condition:
-
Warranty:
- Weight: 0.23 lb
- An innovative tumescent cannula that dramatically improves the technique and speed of the infiltration process
- Blunt-tipped
- Holes encompass 20% of the cannulas' distal end
- Used in the last stage of the infiltration process to ensure both planes are sufficiently anesthetized
-
Learn more:
-
MFR:
HK Surgical
Ships from Manufacturer
-
MPN: IC14TM20
- Phone: (800) 909-0060
+ Free Shipping
Frequently asked questions
Does this cannula significantly improve infiltration speed?
Yes, the HK Surgical Tip Monty Infiltration Cannula is specifically designed to significantly enhance the speed and efficiency of tumescent infiltration.
This improvement is achieved through several key factors:
- Significant Time Reduction: When used optimally—specifically with HK Surgical’s 2X Infiltration Tubing and two Monty Infiltrators—the cannula is reported to reduce total tumescent infiltration time by 25% to 50%.
- Optimized Solution Distribution: The cannula features a specialized blunt tip with holes encompassing 20% of the distal end. This design ensures rapid and effective dispersion of the anesthetic solution during the final infiltration stage, adequately anesthetizing both deep and superficial tissue planes.
- Smoother Procedure: The innovative design helps minimize patient discomfort, potentially rendering routine IM narcotic analgesia unnecessary, which contributes to a smoother and faster overall workflow.
What are the available sizes for this cannula?
The HK Surgical Tip Monty Infiltration Cannula is available in the following standard sizes:
- 14 Gauge: 8 inches length
- 16 Gauge: 6 inches length
- 18 Gauge: 6 inches length
Note that the 16 Gauge, 6 inches (15 cm) variant is preferred for tumescent liposuction when the procedure is performed entirely using local anesthesia.
What are the available cannula gauge and length options?
The HK Surgical Tip Monty Infiltration Cannula is available in the following gauge and length combinations to suit various procedural requirements:
- 14 Gauge: 8” Length
- 16 Gauge: 6” Length
- 18 Gauge: 6” Length
For procedures involving tumescent liposuction performed entirely under local anesthesia, the 16 Gauge, 6” Length variant is the preferred choice.
Does the cannula feature a blunt tip for enhanced patient comfort?
Yes, the HK Surgical Tip Monty Infiltration Cannula features a blunt-tipped design. This design is specifically engineered to enhance patient comfort and safety during the tumescent infiltration process for liposuction procedures.
Does this cannula reduce patient discomfort?
Yes, the HK Surgical Tip Monty Infiltration Cannula is specifically engineered to significantly decrease patient discomfort during the tumescent infiltration procedure. This improvement is achieved through several design features:
- Blunt-Tipped Design: This innovative feature is intended to eliminate or substantially reduce the discomfort often associated with older infiltration techniques.
- Targeted Anesthesia: The specialized distal tip configuration (with holes encompassing 20% of the distal end) ensures effective and even dispersion of the anesthetic solution into both deep and superficial planes, guaranteeing thorough anesthesia.
By optimizing the infiltration process, this device helps practitioners move past reliance on older methods, such as routine intramuscular narcotic analgesia.
Is this cannula compatible with the HK Klein Pump?
Yes, the HK Surgical Tip Monty Infiltration Cannula is engineered for optimal performance when used with the HK Klein Pump.
This compatibility is crucial for the tumescent infiltration technique, providing several workflow advantages:
- Rapid Continuous Flow: It enables the delivery of a continuous, rapid flow of the anesthetic solution.
- Maximized Efficiency: When used alongside the HK Klein Pump and HK Surgical’s 2X Infiltration Tubing, practitioners can potentially reduce the overall infiltration procedure time by 25% to 50%.
This setup ensures the high-volume infiltration required for effective anesthesia in both deep and superficial planes.
Does the blunt tip maximize anesthesia coverage?
Yes, the Tip Monty Infiltration Cannula utilizes a specialized blunt-tipped design specifically engineered to maximize the effectiveness and comfort of tumescent infiltration.
Its key features include:
- Blunt Tip: This configuration is designed to eliminate patient discomfort often associated with alternative infiltration techniques.
- Targeted Porting: The distal holes are precisely positioned to encompass 20% of the cannula’s end area.
- Maximized Coverage: This specific design ensures that the anesthetic solution is thoroughly dispersed across both deep and superficial tissue planes during the final stage of infiltration, guaranteeing sufficient anesthesia.
How much faster is the infiltration process?
The HK Surgical Tip Monty Infiltration Cannula is designed to dramatically improve workflow efficiency during tumescent procedures, offering significant time savings while reducing patient discomfort.<ul><li>Speed Improvement: When used optimally with HK Surgical’s 2X Infiltration Tubing and two Monty Infiltrators, the total tumescent infiltration time can be reduced by 25% to 50%.</li></ul>This rapid infusion technique is intended for use with the HK Klein Pump for optimal flow delivery.
Is the Tip Monty Cannula designed for the final infiltration stage?
Yes, the HK Surgical Tip Monty Infiltration Cannula is specifically engineered for the final stage of the tumescent infiltration process. This design is critical for ensuring comprehensive anesthetic coverage.
Its use in the final step guarantees thorough anesthesia in both the:
- Deep tissue planes
- Superficial tissue planes
The cannula is equipped with a blunt tip and unique porting, where holes encompass 20% of the distal end, optimizing the dispersion of the anesthetic solution during this crucial saturation phase.
Does this cannula have a precision tip design?
Yes, the Tip Monty Infiltration Cannula is specifically engineered with a precision design for enhanced efficiency and patient comfort:
- Blunt Tip: The blunt tip design minimizes patient discomfort and allows for painless insertion once the initial anesthetized path is established.
- Precision Porting: The distal end features specialized holes encompassing 20% of its length. This ensures even and effective dispersal of the anesthetic solution, guaranteeing thorough anesthesia across both the deep and superficial planes during the final infiltration stage.