Sale price$101.51

Special Order Item

Est. Delivery:
<p>Earn%20[points_amount]%20when%20completing%20this%20purchase.</p>

Description

  • McKesson Maxi In-Line Heat and Moisture Exchanger without Port
  • Maxi design for adult use with greater tidal volumes ranging from 350 mL to 1500 mL
  • In-line design allows for use with gas elbow to fit to fit user preference
  • For short-term airway humidification
  • For the moisture and heat retention for return to the patient and provides filtration for prevention of breathing system contamination
  • Optimal choice for enhancing the effectiveness of any breathing systems such as ventilators or anesthesia circuits
  • Bacterial/viral filtration efficiencies in excess of 99.9%
  • High moisture retention characteristics
  • Clear housing to view levels of humidification
  • Provide superior moisture output, minimum size, low breathing resistance
  • True hygroscopic condensing humidifier (HCH) for maximal performance without potentially harmful chemicals
  • Treated with physiologically safe calcium chloride, hygroscopic membrane traps patient’s moisture providing effective airway humidification
  • Low resistance to airflow minimizes work of breathing
  • Effective filtration reduces the risk of colonization in breathing tubes and minimizes sampling line blockage
  • Designed with no port to eliminate risks of a possible leak point
  • ISO-standard connections for secure, leak-resistant attachment to breathing systems
  • Conveniently-located luer connection permits gas sampling at the top of the housing, just as if a common gas sampling elbow were being used
  • Disposable, available in convenient case quantities and individually-wrapped for single patient use
  • Not Made with Natural Rubber Latex
  • 1 Per Pack, 50 Packs Per Case

Product Specs

Item Number 1109633
Catalog Number 16-6379
UOM CS
Level 1 Family Description Respiratory Products
Level 2 Category Description Respiratory Therapy
Level 3 Group Description Humidification
Level 4 Sub-Category Description Heat/Moisture Exchange
Application Heat and Moisture Exchanger with Filter
Brand McKesson
Buy American Act (BAA) Compliant No
Connection Type 22 mm O.D. / 15 mm I.D. X 22 mm I.D. Port
Country of Origin Mexico
Dead Space 49.15 mL
Filter Efficiency BFE 99.9%
Filter Efficiency VFE 99.9%
Filter Type Hygroscopic
Is_ECAT N
Is_GSA N
Is_VA Y
Latex Free Indicator Not Made with Natural Rubber Latex
Manufacturer McKesson Brand
Manufacturer # 16-6379
McKesson # 1109633
Moisture Output 32.1 mg H₂O/L @ VT 500 mL
Port Type Without Port
Resistance 1.43 cm H₂O @ 30 LPM
Size Maxi
Sterility NonSterile
Style Straight
Trade Agreement Act (TAA) Compliant Yes
UNSPSC Code 42272219
User Adult
Volume 350 to 1500 mL

Frequently asked questions

Does this provide effective filtration against pathogens?

Yes, this device offers high-performance protection. It features a 99.9% bacterial and viral filtration efficiency (BFE/VFE) to significantly minimize the risk of contamination within breathing systems.

Is the humidifier safe for the patient?

Absolutely. It utilizes a hygroscopic membrane treated with calcium chloride to capture the patient’s own moisture. This method provides superior humidification output without the use of potentially harmful chemicals.

Will this make breathing difficult for the patient?

The device is engineered with a low-resistance design to ensure ease of use. With a resistance of just 1.43 cm H₂O at 30 LPM, it is specifically built to help reduce the patient’s work of breathing.

Is this suitable for adult patients?

Yes, the ‘Maxi’ design is specifically optimized for adults. It supports a tidal volume range of 350 mL to 1500 mL, making it versatile for various respiratory therapy needs.

Can I easily monitor the unit during use?

Yes, the HME is constructed with a clear, durable plastic housing. This allows clinicians to perform easy visual inspections of humidification levels throughout the treatment.

Is this product made with latex?

No, this product is not made with natural rubber latex, ensuring it is suitable for patients with latex sensitivities.

Is the device compatible with standard hospital equipment?

Yes, it features ISO-standard connections (22 mm O.D. / 15 mm I.D. X 22 mm I.D. Port), allowing for a secure, leak-resistant attachment to most anesthesia circuits and ventilators.

Does the unit allow for easy gas sampling?

Yes, it includes a conveniently located luer connection at the top of the housing, which allows for efficient and quick gas sampling during clinical use.

Does this require any assembly before use?

No, the device requires zero assembly. It comes ready for immediate integration into your existing anesthesia circuits or ventilator systems.

How much moisture output can I expect?

The device provides a consistent moisture output of 32.1 mg H₂O/L at a tidal volume of 500 mL, ensuring reliable humidification performance for the patient.