Sale price$55.59

Special Order Item

Estimated Delivery:
<p>Earn%20[points_amount]%20when%20completing%20this%20purchase.</p>

Description

Heat and Moisture Exchanger with Filter McKesson 28 mg H₂O/L 5 LPM Angled (Case of 25 Packs)


  • Sold by: Case
  • Contents: 25 packs per case
  • McKesson Angled Inlet Heat and Moisture Exchanger
  • Tidal volume of 20 mL for infant use
  • Angled inlet eliminates need for gas sampling elbow
  • For short-term airway humidification
  • For the moisture and heat retention for return to the patient and provides filtration for prevention of breathing system contamination
  • Optimal choice for enhancing the effectiveness of any breathing systems such as ventilators or anesthesia circuits
  • Bacterial filtration efficiencies in excess of 99.8%
  • Viral filtration efficiencies in excess of 99.6%
  • Clear housing to view levels of humidification
  • High moisture retention characteristics
  • Provide superior moisture output, minimum size, low breathing resistance
  • True hygroscopic condensing humidifier (HCH) for maximal performance without potentially harmful chemicals
  • Treated with physiologically safe calcium chloride, hygroscopic membrane traps patient’s moisture providing effective airway humidification
  • Low resistance to airflow minimizes work of breathing
  • Effective filtration reduces the risk of colonization in breathing tubes and minimizes sampling line blockage
  • End tidal CO2 sampling port offers convenient access to airway gases
  • Luer gas sampling ports for secure connection
  • ISO-standard connections for secure, leak-resistant attachment to breathing systems
  • Disposable available in convenient case quantities and individually-wrapped for single patient use
  • Not Made with Natural Rubber Latex
  • 1 Per Pack, 25 Packs Per Case

Frequently asked questions

Does this HMEF provide high-level bacterial protection?

Yes, this device is engineered for safety with high-efficiency filtration:

  • Bacterial Filtration Efficiency (BFE): >99.8%
  • Viral Filtration Efficiency (VFE): >99.6%
    These metrics help ensure superior protection against breathing system colonization.
Is the design optimized for infant respiratory needs?

Absolutely. This filter is specifically built for infant care, featuring:

  • Optimized Tidal Volume: 20 mL capacity.
  • Minimal Resistance: Only 1.25 cm H₂O @ 5 LPM, helping to reduce the patient’s work of breathing.
How effective is the moisture retention performance?

It provides reliable and consistent airway humidification, delivering an output of 28 mg H₂O/L. It utilizes a high-quality hygroscopic condensing humidifier (HCH) membrane treated with calcium chloride for superior moisture output.

Does it simplify the breathing circuit setup?

Yes, the integrated design streamlines your workflow by:

  • Eliminating extra parts: The angled inlet removes the need for a separate gas sampling elbow.
  • Convenient Monitoring: It includes an integrated Luer connection port for easy gas sampling.
Is the material safe for sensitive patients?

The device is constructed with patient safety in mind and is not made with natural rubber latex. Furthermore, the hygroscopic membrane is treated with physiologically safe calcium chloride rather than harsh or harmful chemicals.

Can I easily monitor the filter during use?

Yes, the housing is constructed from clear, high-grade material. This allows for simple and effective visual inspection of humidification levels and the internal status of the filter medium at any time.

What is the best way to position this in a circuit?

For maximum efficacy, the unit should be fitted at the patient end of the breathing circuit. Please note that it is not intended for use between the patient and a separate nebulizer or humidifier.

Are there any indicators that the filter is working correctly?

Yes. It is normal to observe small water droplets or salt crystals within the housing. These are standard byproducts of the hygroscopic membrane effectively capturing moisture and should not be cause for concern.

Is this a lightweight solution for medical circuits?

The device is designed with a technical, minimalist profile. It is exceptionally lightweight, ensuring it can be integrated into infant ventilator or anesthesia circuits without adding unnecessary bulk or mechanical stress to the system.

Does this meet professional clinical standards?

Yes, this McKesson product is TAA Compliant and VA Approved, confirming it meets the rigorous standards required for professional medical and clinical environments.