Regular price$25,835.00 Sale price$19,326.97
Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+

Description

The GE CASE Performance ECG System includes:

  • #2062898-001: CASE v6.7.
  • #2062898-824: CASE Windows 10 Performance PKG with Display (RESB, RESM, ERG2, PRVT, ARRY, ERG3, ECGH, THWR, ITRD, ITBL, DSPC, EGMO, NETS, NET2,NET3, EPDF).
  • #2062898-740: Patient EKG Acquisition Module - AHA.
  • #2062898-490: CASE v6.7 Language Set, ENG US (Win 8).
  • #2026714-078: CASE v6.7 Power Cord, North American.

Warranty: 1 Year.

The CASE System is a stand-alone, highly scalable exercise testing solution that helps physicians quickly and easily access cardiac function during exercise. Its exclusive ergonomic features include a backlit keyboard and well-lit printing surface for effortless and confident operation in rooms darkened for stress echo tests. A centrally mounted, full-size monitor swivels for comfortable viewing. A familiar, Windows XP-based interface minimizes the learning curve. And a flexible interface accommodates multiple custom set-ups.

With the GE CASE Exercise Testing System, clinicians can easily acquire, analyze, store, and transport resting ECG, exercise stress tests, ambulatory blood pressure and spirometry measurements using one system. The CASE's streamlined workflow and digital connectivity help speed patient care and increase staff productivity. The CASE features an adjustable monitor for comfort and productivity, open system architecture, advanced security and compliance, and technical support services you can count on.

Connect your CASE System to a local area network (LAN), and you can store patient data and test results to a central database. This enables physicians to review, edit, and print data remotely, for maximum efficiency in your stress lab.

Features

GE CASE Performance ECG System Features

  • Assess cardiac function conveniently during exercise.
  • Innovative algorithms offer great diagnostic confidence.
  • Connect your CASE system to a Local Area Network (LAN), and store patient data and test results to a central database.
  • Physicians can review, edit, and print data remotely.
  • Enhance your digital workflow with connectivity to EMR, MUSE Cardiology Information System, and PACS.
  • Advanced security and compliance.
  • Productivity tools help to speed processes, reduce data entry errors, download orders, and support efficient change capture.
  • Access cardiac function conveniently during exercise.

Specifications

GE CASE Performance ECG System Specifications

  • ECG Analysis Frequency: 500 Hz.
  • ST Measurements: ST amplitudes, slope, integral, index, ST/HR slope, ST/HR loops, ST/HR index up to 15 leads.
  • E, J, and Post-J Point: Manual or computer selected.
  • Signal Processing Technique: Incremental updating to minimize artifact in all leads.
  • Baseline Correction: Cubic Spline or Finite Residual Filter algorithm.
  • QRS Detection/Analysis: Based on automatic or manual lead selection.
  • ECG Output: Real-time ECG/QRS beep/TTL synchronization output.
  • Heart Rate: Automatic arrhythmia detection, documentation, and annotation.
  • Full Disclosure ECG: Beat-to-beat ECG record and event review.
  • Reanalysis: Post-test medians remeasurement from E, J, post-J point selections.
  • In-Test Reports:
    • 12SL: Interpretive resting ECG with analytical statements on morphology, rhythm, and conduction. Measurements of rate, intervals, and axes. Available before the test, in pretest and recovery. Formats include: 4 x 2.5; 4 x 2.5 + 1, 2 x 5; H2 (5 s ECG at a speed of 50 mm/s x 6) and H1 (6-lead ECG at 12.5 mm/s, Medians at 50 mm/s).
    • 3, 6, 12, or 15-Lead Report: Presents raw ECG data in various formats: 4 x 2.5 s ECG; 4 x 2.5 + 1 (2.5 seconds of raw data plus 1 continuous 10 second recording of continuous rhythm); 2.5 x 5 (5 seconds of raw data); 1 x 10 (10 seconds of raw data); H2 format (5 seconds of raw data at a speed of 50 mm/s x 6).
    • Rhythm Report: A continuous, real-time recording of raw ECG data: 3, 6, 12 leads. Leads for arrhythmia report correspond to leads on the screen (not with laser printer).
    • Arrhythmia Report: Automatic 10-second documentation of arrhythmias showing 2.5 seconds of raw data prior to ectopic beat. Leads for arrhythmia report correspond to leads on the screen.
    • Recall Report: A delayed recording of raw data 10 seconds in duration: 3, 6, 12 leads.
    • Comparative Medians Report: Baseline and current medians followed by 2.5 seconds of real-time rhythm in 12 leads. ST level and ST slope reported for each lead. Also comes in H1 Medians format of 12 medians at 50 mm/s + 6 leads (selectable) of 10-second channel of raw, real-time rhythm.
    • Linked Medians Report: 4 x 2.5 with rhythm lead. 3 channels of median beat which are linked together at the current heart rate with a fourth 10-second channel of raw, real-time rhythm.

Configurations

GE CASE Performance ECG System Configurations

  • XEMR (#3031234-001-01348161:
    • #2062898-068: EMR - Centricity Practice Solution (XEMR).
  • 12SL, XEMR (#2062898-001-580892):
    • #2062898-050: 12SL Interpretation (RESI).
    • #2062898-068: EMR - Centricity Practice Solution (XEMR).
  • 12SL, MUSE, XEMR (#2062898-001-580925):
    • #2062898-050: 12SL Interpretation (RESI).
    • #2062898-063: MUSE Browser (BRWS).
    • #2062898-068: EMR - Centricity Practice Solution (XEMR).
  • 12SL, XML Excel (#2062898-001-580936):
    • #2062898-050: 12SL Interpretation (RESI).
    • #2062898-065: XML EXCEL Export (EXPD).
    • #2062898-068: EMR - Centricity Practice Solution (XEMR).
  • 12SL, MUSE, RISK, XEMR (#2062898-001-582629):
    • #2062898-050: 12SL Interpretation (RESI).
    • #2062898-063: MUSE Browser (BRWS).
    • #2062898-068: EMR - Centricity Practice Solution (XEMR).
  • 12SL, DICOM, XEMR (#2062898-001-580912):
    • #2062898-050: 12SL Interpretation (RESI).
    • #2062898-068: EMR - Centricity Practice Solution (XEMR).
    • #2062898-034: DICOM Option and Conformance Statement.
  • DICOM, XEMR, XML Excel (#2062898-001-580897):
    • #2062898-034: DICOM Option and Conformance Statement.
    • #2062898-065: XML EXCEL Export (EXPD).
    • #2062898-068: EMR - Centricity Practice Solution (XEMR).
  • 12SL, HRST/EXTI, MUSE, XML Excel (#2062898-001-604730):
    • #2062898-050: 12SL Interpretation (RESI).
    • #2062898-059: HR-HYST/STRESS Interpretation (HRST/EXTI) (Value and Performance only).
    • 2062898-063: MUSE Browser (BRWS).
    • 2062898-065: XML EXCEL Export (EXPD).
  • 12SL, ITBL, ITRD, RISK, HRST/EXTI, XML-PDF-Word, XMR (#2062898-001-585834):
    • #2062898-050: 12SL Interpretation (RESI).
    • #2062898-052: Risk Factors (RISK).
    • #2062898-059: HR-HYST/STRESS Interpretation (HRST/EXTI) (Value and Performance only).
    • #2062898-038: Combined option - XML-PDF-WORD.
  • 12SL, DICOM, XML-PDF-Word (#2062898-001-580907):
    • #2062898-050: 12SL Interpretation (RESI).
    • #2062898-034: DICOM Option and Conformance Statement.
    • #2062898-038: Combined option - XML-PDF-WORD.
  • 12SL, XML, PDF, DICOM, RISK (#2062898-001-620344):
    • #2062898-050: 12SL Interpretation (RESI).
    • #2062898-052: Risk Factors (RISK).
    • #2062898-066: XML PDF Export (EXPD/EPDF).
    • #2062898-034: DICOM Option and Conformance Statement.
  • 12SL, DICOM, XML-PDF-Word, MUSE (#2062898-001-591999):
    • #2062898-050: 12SL Interpretation (RESI).
    • #2062898-034: DICOM Option and Conformance Statement.
    • #2062898-038: Combined option - XML-PDF-WORD.
    • #2062898-063: MUSE Browser (BRWS).
  • 12SL, ITBL, ITRD, RISK, HRST/EXTI, DICOM, XML-PDF-Word, XMER (#2062898-001-585826):
    • #2062898-050: 12SL Interpretation (RESI).
    • #2062898-052: Risk Factors (RISK).
    • #2062898-059: HR-HYST/STRESS Interpretation (HRST/EXTI) (Value and Performance only).
    • #2062898-034: DICOM Option and Conformance Statement.
    • #2062898-038: Combined option - XML-PDF-WORD.
    • #2062898-068: EMR - Centricity Practice Solution (XEMR).

Frequently asked questions

What tests can the comprehensive system perform?

The GE CASE Performance ECG System is a unified, highly scalable exercise testing solution designed for comprehensive cardiac assessment. It allows clinicians to acquire, analyze, store, and transport several critical measurements using a single platform, including:

  • Resting ECG
  • Exercise stress tests
  • Ambulatory blood pressure
  • Spirometry measurements

This broad functionality, supported by features like advanced connectivity (EMR, MUSE, PACS) and detailed 12SL interpretation, helps streamline workflows and enhance diagnostic confidence.

Does the system feature advanced digital connectivity?

Yes, the GE CASE Performance ECG System is built for robust digital integration, significantly streamlining workflows and enhancing data management within the cardiology department.

Key features supporting its advanced connectivity include:

  • Clinical System Integration: It supports connectivity to critical enterprise platforms such as EMR (Electronic Medical Record), PACS (Picture Archiving and Communication Systems), and the MUSE Cardiology Information System.
  • Centralized Data Access: LAN capability enables the storage of patient data and test results on a central database, facilitating remote review, editing, and printing for maximum efficiency in the stress lab.
  • Digital Workflow Tools: The system offers productivity tools to speed processes and supports efficient change capture. Specific configurations also support output formats like DICOM, XML, and PDF for comprehensive digital documentation.
Does the system have an ergonomic design for low-light rooms?

Yes, the GE CASE Performance ECG System is specifically designed with ergonomic features to ensure confident operation, even in low-light clinical environments required for procedures like stress echo tests.

Key ergonomic features include:

  • Effortless Operation in Darkness: The system features a backlit keyboard and a well-lit printing surface, allowing staff to work comfortably and accurately in dimmed conditions.
  • Optimal Viewing: It includes a centrally mounted, swiveling full-size monitor that ensures ideal viewing angles throughout the procedure.
  • Workflow Efficiency: The system’s mobile, cart-based design maximizes flexibility and positioning within the stress lab environment.
Does it have a high ECG analysis frequency?

Yes, the GE CASE Performance ECG System boasts a high ECG analysis frequency of 500 Hz. This feature allows for precise and detailed cardiac assessments during exercise testing.

Does it offer automatic arrhythmia detection?

Yes, the GE CASE Performance ECG System provides automatic arrhythmia detection, documentation, and annotation for precise heart rate monitoring during testing.

What components are included in the GE CASE ECG System?

The GE CASE Performance ECG System is delivered Factory New and includes a robust set of essential hardware and software for comprehensive exercise testing and analysis.

The core system components included in the base configuration are:

  • Core Software: CASE v6.7
  • Performance Package: CASE Windows 10 Performance PKG with Display
  • Acquisition Module: Patient EKG Acquisition Module - AHA
  • Language & Power: CASE v6.7 Language Set (English US) and North American Power Cord

Additionally, the Performance Package incorporates various integrated software modules to support advanced functions. These standard modules include: RESB, RESM, ERG2, PRVT, ARRY, ERG3, ECGH, THWR, ITRD, ITBL, DSPC, EGMO, NETS, NET2, NET3, and EPDF.

What advanced reports does the system generate?

The GE CASE Performance ECG System provides extensive reporting options for confident cardiac assessment, supporting sophisticated analysis up to 15 leads with a 500 Hz ECG analysis frequency.

The system generates the following detailed reports and diagnostic outputs:

  • Interpretive Resting ECG (12SL): Provides analytical statements on morphology, rhythm, conduction, rate, intervals, and axes.
  • Standard Lead Reports: Comprehensive raw data reports available in 3, 6, 12, or 15-Lead formats.
  • Arrhythmia and Rhythm Reports: Provides automatic detection, documentation, and annotation of arrhythmias, along with continuous rhythm monitoring.
  • Comparative Medians Report: Allows comparison of median beats, showing detailed ST level and slope data for each lead.
  • Linked Medians Report: Connects three channels of the median beat with a fourth channel of 10-second raw, real-time rhythm data.
  • Recall Report: Enables delayed recording and review of raw data.

Additionally, the system includes Full Disclosure ECG capability for beat-to-beat review and Post-Test Reanalysis for remeasuring data based on selected E, J, and post-J points.

What patient data does the CASE system store?

The GE CASE Performance ECG System is a comprehensive exercise testing solution designed to acquire, analyze, store, and transport a variety of crucial patient data and test results. The system is capable of managing:

  • Resting ECG (including 12SL interpretive analysis)
  • Exercise Stress Tests (with detailed ST measurements and reanalysis features)
  • Ambulatory Blood Pressure
  • Spirometry Measurements

For enhanced digital workflow, patient data and test results can be stored centrally via LAN connectivity, enabling remote review and printing. The system also supports connectivity to EMR, PACS, and the MUSE Cardiology Information System.

Does the system have comprehensive digital connectivity?

Yes, the GE CASE Performance ECG System is engineered for advanced digital integration to optimize clinical workflows and enhance productivity. It facilitates streamlined acquisition, storage, and transport of cardiac function data.

The system features comprehensive connectivity options:

  • LAN Capability: Allows for storing patient data on a central database, enabling efficient remote review, editing, and printing of test results within the stress lab.
  • EMR Integration: Connects seamlessly with Electronic Medical Record (EMR) systems.
  • Cardiology Information Systems: Supports direct integration with the MUSE Cardiology Information System.
  • PACS Connectivity: Integrates with Picture Archiving and Communication Systems.
Does the system use innovative diagnostic algorithms?

Yes, the GE CASE Performance ECG System is specifically engineered for high diagnostic confidence and utilizes advanced analytical algorithms to ensure accurate and comprehensive results during exercise testing.

Key analytical features that enhance diagnostic reliability include:

  • Detailed ST Measurements: Performs extensive ST measurements, including amplitudes, slope, integral, and ST/HR index, across up to 15 leads.
  • Artifact Minimization: Uses incremental updating signal processing techniques to minimize artifacts in all leads, ensuring cleaner data.
  • Accurate Baseline Correction: Employs sophisticated algorithms (Cubic Spline or Finite Residual Filter) for precise baseline correction.
  • 12SL Interpretation: Provides comprehensive interpretive resting ECG analysis.
  • Automated Detection & Reanalysis: Features automatic arrhythmia detection, documentation, and annotation, along with post-test reanalysis capability for remeasuring medians from selected points (E, J, post-J).