Sale price$3,705.00
Earn 3705 points

Ships from Manufacturer

Est. Delivery: 

Shop with Confidence

Description

The GE CARESCAPE VC150 Vital Signs Monitor includes:

  • #2068596-001: US Power Cord.
  • #2081101-001: SOFT-CUF Kit (1 Small, 1 Adult, 1 Large, 1 Radial 2T, 1 Hose 2T DINACLICK 12FT).
  • #2068623-001: English Language Localization.
  • #2102572-001: EWS Platform Option.
  • #2102571-001: USA Region WLAN Option.
  • Printer.

Warranty: 2 Years.

The GE CARESCAPE VC150 Vital Signs Monitor sends accurate patient data directly and wirelessly to your EMR system. Its configurable monitor can be used for spot-checking or for continuous monitoring, providing you the flexibility of two devices in one.

Features

GE CARESCAPE VC150 Vital Signs Monitor Features

  • Designed for adult, pediatric, and neonatal patients, including those with low perfusion rates.
  • Non-invasive blood pressure measurement uses DINAMAP Technology.
  • Three choices for pulse oximetry: GE TruSignal, Nellcor OxiMax, or Masimo rainbow SET.
  • Two choices for temperature: Exergen TemporalScanner or Welch Allyn SureTemp.
  • EMR connectivity minimizes charting errors and decreases the lag time between vitals capture and EMR documentation from hours to seconds, enabling nurses to focus more on their patients.

Specifications

GE CARESCAPE VC150 Vital Signs Monitor Specifications

  • Dimensions 9.75" x 9.5" x 5.3" (24.7 cm x 24.2 cm x 13.6 cm).
  • Weight: 6.2 lb (2.8 kg) including battery.
  • Mounting Options: Self-supporting on rubber feet. Optional roll stand or wall mount.
  • Height to mounting Platform: 40" (101 cm) from floor to lowest position 35" (144 cm) from floor to highest position.
  • TruSignal SpO2:
    • SpO2 Saturation Range: 0 to 100%.
    • Pulse Rate Range: 30 to 300 bpm.
    • SpO2 Saturation Accuracy: 70% to 100% +/- 2 to +/- 3 digits.
    • Pulse Rate Accuracy: 30 to 250 bpm +/- 2 bpm to +/- 5 bpm (rms).
  • Nellcor SpO2:
    • SpO2 Saturation Range: 1 to 100%.
    • Pulse Rate Range: 20 to 250 bpm.
    • Respiration Rate Range: 4 to 40 breaths/minute.
    • SpO2 Saturation Accuracy: 70% to 100% +/- 2 to +/- 3.5 digits.
    • Pulse Rate Accuracy: 20 to 250 bpm +/- 3 bpm (rms).
  • Masimo SpO2:
    • SpO2 Saturation Range: 0 to 100%.
    • Pulse Rate Range: 25 to 240 bpm.
    • SpCO Range: 0 to 99%.
    • SpMet Range: 0 to 99.9%.
    • SpHb Range: 0 to 25 g/dl.
    • Respiratory Rate Range: 0 to 70 breaths/minute.
    • SpO2 Saturation Accuracy: 70% to 100% +/- 2% to +/- 3.5%.
    • Pulse Rate Accuracy: 25 to 240 bpm +/- 3 to +/- 5 bpm (rms).
    • Respiration Rate Accuracy: 4 to 70 +/- 1 breaths/minute.
    • SpCO Accuracy: 1 to 40 +/- 3%.
    • SpMet Accuracy: 1 to 15 +/- 1%.
    • SpHb Accuracy: 8 to 17 +/- 1 g/dl (arterial or venous).
  • NIBP Measurement Range (Auscultatory Algorithm):
    • Systolic BP Range: 30 to 245 mmHg (adult/ped).
    • MAP Range: 15 to 215 mmHg (adult/ped).
    • Diastolic BP Range: 10 to 195 mmHg (adult/ped).
    • Pulse Rate Range: 30 to 200 beats/min (adult/ped).
  • NIBP Measurement Accuracy (Auscultatory Algorithm):
    • Blood Pressure Accuracy: mean error less than or equal to 5 mmHg, standard deviation less than or equal to 8 mmHg.
    • Pulse Rate Accuracy: +/- 3.5% or 3 bpm, whichever is higher.
  • Measurement Range (SuperSTAT Algorithm):
    • Systolic BP Range:
      • Adult/Pediatric: 30 to 290 mmHg.
      • Neonate: 30 to 140 mmHg.
    • MAP Range:
      • Adult/Pediatric: 20 to 260 mmHg.
      • Neonate: 20 to 125 mmHg.
    • Diastolic BP Range:
      • Adult/Pediatric: 10 to 220 mmHg.
      • Neonate: 10 to 115 mmHg.
    • Pulse Rate Range:
      • Adult/Pediatric: 30 to 240 beats/minute.
      • Neonate: 30 to 240 beats/minute.
  • Measurement Accuracy (SuperSTAT Algorithm):
    • Blood Pressure Accuracy: mean error less than or equal to 5 mmHg, standard deviation less than or equal to 8 mmHg.
    • Pulse Rate Accuracy: +/- 3.5% or 3 bpm, whichever is higher.
  • Welch Allyn Temperature Accuracy and Ranges:
    • Patient Temperature Range: 26.7 degrees C to 43.3 degrees C (80 degrees F to 110 degrees F).
    • Monitor Mode Temperature Accuracy: +/- 0.1 degrees C (+/- 0.2 degrees F).
  • Exergen Temperature Accuracy and Ranges:
    • Temperature Range: 16 degrees C to 43 degrees C (61 degrees F to 110 degrees F).
    • Temperature Accuracy: +/- 0.1 degrees C (+/- 0.2 degrees F).

Configurations

GE CARESCAPE VC150 Vital Signs Monitor Configurations

  • #2068581-001-625828: Suretemp, Dinaclick - No Networking, SuperStat, Continuous Measurement Option.
  • #2068581-001-625827: Exergen, Dinaclick - No Networking, SuperStat, Continuous Measurement Option.
  • #2068581-001-607604: Masimo, Exergen, Dinaclick - No Networking.
  • #2068581-001-577251: Masimo, Exergen, Dinaclick - No Networking, SuperStat, Continuous Measurement Option.
  • #2068581-001-599008: GE TruSignal, SureTemp, Dinaclick, SuperStat, Continuous Measurement Option.
  • #2068581-001-599001: GE TruSignal, Exergen, Dinaclick, SuperStat, Continuous Measurement Option.
  • #2068581-001-599003: Nellcor, SureTemp, Dinaclick, SuperStat, Continuous Measurement Option.
  • #2068581-001-599005: Masimo, SureTemp, Dinaclick, SuperStat, Continuous Measurement Option.
  • #2068581-001-599000: Nellcor, Exergen, Dinaclick, SuperStat, Continuous Measurement Option.
  • #2068581-001-599002: Masimo, Exergen, Dinaclick, SuperStat, Continuous Measurement Option.
  • #AHS-60150VC: Certified: Nellcor, Exergen, Dinaclick, SuperStat, Continuous Measurement Option.

Literature

GE CARESCAPE VC150 Vital Signs Monitor Literature

GE CARESCAPE VC150 Vital Signs Monitor Connectivity Brochure

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)