Sale price$254.24
Est. Delivery:
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Dynarex DynaRest Airfloat 500 Air Mattress with Pump (#10447) supports up to 350 lb and helps patients with treating pressure wounds.

Note: Bed frame is not included.

Warranty: 1 Year.

The Dynarex DynaRest Airfloat 500 Air Mattress with Pump is equipped with 19 air cells that measure eight inches each, along with 18 laser holes that prevent low air loss. The mattress pump features two modes: alternating cycle and static mode. The alternating cycle performs alternating pressure to maintain a specific comfort level, while the static mode activates all the air cells to allow for easier transfer and repositioning. Caregivers can use the air flow dial to manually adjust the mattress to the patient's needs.

For safety features, the mattress includes a CPR valve for rapid deflation, an audible alarm to alert caregivers, and a low pressure indicator light. 

Features

Dynarex DynaRest Airfloat 500 Air Mattress with Pump Features

  • Includes two modes: alternating cycle and static mode.
  • Safety features include CPR valve, low pressure indicator, and an alarm.
  • Supports up to 350 lb.

Specifications

Dynarex DynaRest Airfloat 500 Air Mattress with Pump Specifications

  • Weight Capacity: 350 lb.
  • Number of Cells: 19.
  • Power Supply: 120 V / 60 Hz, 1A.
  • Pump Weight: 3 lb.
  • Mattress Length: 80".
  • Mattress Width: 35".
  • Mattress Weight: 16.5 lb.

Frequently asked questions

What is the maximum patient weight supported?

This specialized air mattress system is designed to safely support patients weighing up to 350 lb.

Does the pump offer alternating and static modes?

Yes, the accompanying pump features dual operational modes to optimize patient care and pressure management:

  • Alternating Cycle Mode: This mode continuously changes pressure in the 19 air cells (each 8 inches deep) to provide cyclical pressure redistribution and relief.
  • Static Mode: This mode fully inflates all air cells simultaneously, creating a firm surface. This is specifically designed to facilitate easier patient transfers and safe repositioning by caregivers.
Does the system include essential safety features?

Yes, the DynaRest Airfloat 500 is equipped with crucial safety features designed to protect the patient and alert caregivers:

  • CPR Valve: Allows for rapid, emergency deflation of the mattress.
  • Audible Alarm: Provides a sound alert for immediate notification of system issues or safety concerns.
  • Low Pressure Indicator Light: A visual alert system that notifies caregivers if the air pressure drops below the required level.
What size is the Dynarex DynaRest Airfloat 500 mattress?

The Dynarex DynaRest Airfloat 500 mattress is generously sized to fit standard hospital bed frames. The exact dimensions are:

  • Length: 80 inches
  • Width: 35 inches

Additionally, the system features 19 individual air cells, each providing 8 inches of height for deep pressure redistribution.

How many 8-inch pressure therapy cells are included?

The Dynarex DynaRest Airfloat 500 air mattress utilizes 19 individual 8-inch air cells to provide deep support and dynamic pressure redistribution. This crucial design feature is specifically engineered to assist in the treatment and management of pressure wounds.

Key specifications related to the air cell design include:

  • Cell Count: 19 large air cells for comprehensive body surface coverage.
  • Cell Height: Each cell measures 8 inches high, optimizing pressure relief.
  • Low Air Loss Prevention: The system incorporates 18 laser holes designed to prevent low air loss and ensure consistent therapeutic pressure.
What components are included?

The Dynarex DynaRest Airfloat 500 system is a complete package for pressure relief. It includes the following components:

  • Air Mattress: This is the support surface featuring 19 individual, 8-inch air cells for dynamic pressure redistribution.
  • Air Pump Unit: The external unit that provides the alternating cycle and static modes, equipped with an audible alarm and low-pressure indicator.
  • Necessary Tubing/Hoses: These connect the pump unit securely to the air mattress.
What power supply does the pump require?

The pump operates on a standard power supply of 120 V / 60 Hz, 1A.

What are the benefits of the dual cycling modes?

The Dynarex DynaRest Airfloat 500 pump offers two essential modes to support patient care and pressure wound management:

  • Alternating Cycle: This mode performs sequential pressure changes across the 19 eight-inch air cells to ensure continuous comfort and help treat pressure wounds.
  • Static Mode: This mode inflates all air cells simultaneously, creating a firm surface to facilitate easier and safer patient transfer and repositioning.

Caregivers can also manually adjust the pressure intensity using the dedicated air flow dial on the pump.

What are the weights of the mattress and pump?

The Dynarex DynaRest Airfloat 500 system is designed for relatively easy handling and has the following component weights:

  • Air Mattress: 16.5 lb
  • Air Pump Unit: 3 lb
Does this mattress feature low air loss technology?

Yes, the Dynarex DynaRest Airfloat 500 is specifically designed to manage pressure wounds and includes features to prevent low air loss. This aids in providing consistent pressure support and comfort.

Key features supporting pressure management include:

  • 19 individual air cells: Each cell measures eight inches high, providing deep flotation support.
  • 18 laser holes: These specialized holes are integrated into the air cells specifically to prevent low air loss, helping to maintain stable pressure redistribution throughout the alternating cycle.