Sale price$10,133.31
Est. Delivery:
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The Drager Apollo Anesthesia Machine includes a built-in gas module, built-in gas (anesthetic agents, CO2, O2) display, container of Sodasorb, O2 sensor, two flow sensors, two new batteries, power cord, and software version 04.53.05.

Warranty: 90 Days - Parts and Labor.

Note: Patient monitors and vaporizers are sold separately. Please refer to the Accessories section for a list of recommended compatible accessories sold at MFI Medical.

From the reliable line of Drager medical products comes the Apollo Anesthesia Machine. With a heightened emphasis on cost reduction in healthcare, Drager anesthesia solutions help you reduce operating costs and maximize reimbursement.

The Drager Apollo Anesthesia Machine can play an important role in optimizing your anesthesia workflow and reducing process costs with features such as the fully automatic self-test. Little user interaction is required allowing the caregiver to focus more on the patient.

In addition to providing you with invaluable assistance through best-in-class therapy, Apollo also offers you an open-platform architecture - enabling it to be easily integrated into your overall workflow. The Apollo features a built-in gas and O2 monitor. You can monitor gasses and O2 levels through the built-in display, meaning the only auxiliary monitor needed is a vital signs monitor.

Features

Drager Apollo Anesthesia Machine Features

  • Advanced Ventilation: It has the ventilation technology to support patients of any age and acuity. The E-Vent plus servo controlled high-speed piston ventilator works with great precision to supply a maximum peak flow far in excess of any bellows ventilator, resulting in the kind of performance previously only seen in the ICU. Additionally, unlike a bellows ventilator, it requires no drive gas. The very short response time has clear physiological benefits for your patients, while the digital precision helps you make the most of the latest ventilation modes.
  • Unique Low-Flow Wizard: Designed to support the user by providing optimal low and minimal flow settings. The consistent use of low-flow anesthesia techniques can significantly reduce the cost of inhalation anesthetic agents. Reducing the fresh gas flow from 3 L/min to 1 L/min can result in anesthetic agent savings of up to 50%.
  • Automated Startup:
    • Simple straightforward startup makes it easier for the staff and provides complete information on device status.
    • Enhanced troubleshooting with clear text directions.
    • Integrated breathing system eliminates external hoses and clutter, reducing the risk of misconnection and disconnection.
    • Fully automatic self-test lasts approximately three minutes, reflects the results to the user, and makes results available to the user at any time.
  • Monitoring:
    • Standard: Inspiratory and expiratory concentration of O2, N2O, CO2 as well as anesthetic agents (Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane); Minute volume (MV) and Tidal volume (VT); Breathing frequency; Peak pressure, plateau pressure, mean pressure, PEEP; Patient compliance CPAT.
    • Optional: Functional oxygen saturation (SpO2).
    • The following parameters maybe displayed as waveforms:
      • Standard: Concentration of CO2, O2, as well as anesthetic agents, airway pressure, inspiratory and expiratory flow.
      • Optional: Plethysmogram; Bar graph display of volumeter and tidal volume; Virtual flow tubes for O2, AIR, N2O; Display of graphical trends and numerical lists of measured values; AutoSet for alarm limits.

Specifications

Drager Apollo Anesthesia Machine Specifications

  • Weight: 365 lb (165 kg) without vaporizers and gas cylinders.
  • Dimensions: 59" (H) x 33.5" (W) x 31.5" (D) (150 cm x 85 cm x 80 cm).
  • Power: 200 W, typically.
  • Operating Voltage: 100 to 127 VAC (-15% + 10%), 45 to 65 Hz.
  • Integrated Power Backup: At least 30 min, typically 90 min; Depending on ventilation parameters.
  • Ventilator E-Vent plus: Electrically driven and electronically controlled, fresh gas decoupled.
  • Ventilation Modes:
    • Standard: Manual, spontaneous, Volume Mode, Pressure Mode.
    • Optional/Synchronization: Pressure Support (PS).
  • Pressure Limitation PMAX (in Volume Mode): (PEEP + 10) up to 70 cmH2O.
  • Pressure Limitation PINSP (in Pressure Mode): (PEEP + 5) up to 70 cmH2O.
  • Trigger: 0.3 to 15 L/min.
  • Tidal Volume VT (compliance compensated) (in Volume Mode):
    • Standard: 20 to 1400 mL.
    • With Advanced Ventilation option: 5 to 1400 mL.
  • Breathing Frequency: 3 to 100 bpm.
  • Inspiration Time (TINSP): 0.2 to 6.7 s.
  • Inspiration/Expiration Time Ratio (I:E): 5:1 max.
  • Plateau Time (TIP:TINSP): 0 to 60%.
  • Inspiratory Flow (in Pressure Mode): 150 L/min max.
  • PEEP:
    • In Volume Mode: 0 to 20 cmH2O (max. PMAX - 10 cmH2O).
    • In Pressure Mode: 0 to 20 cmH2O (max. PINSP - 5 cmH2O).
  • Fresh-Gas Flow: 0 to 10 L/min for each gas (oxygen, air, nitrous oxide).
  • TSLOPE (in Pressure Mode and Pressure Support): 0 to 2 s.
  • Total System Leakage: Less than 150 mL/min at 30 cmH2O (automatic leak test).
  • O2 Flow Control: Sensitive ORC Function: At least 21 Vol.-% with N2O as carrier gas.
  • O2 Flush: Greater than 35 L/min.
  • Serial Interface: 2 x RS 232.
  • Protocol: Medibus, Medibus X.
  • Absorber Volume (reusable canister): 1.5 L.

Accessories

Drager Apollo Anesthesia Machine Accessories

The following accessories are compatible and commonly purchased with the Apollo Anesthesia Machine:

  • #55-01-0019: Allied Healthcare Litholyme Carbon Dioxide Absorbent - Drager Style Cartridge.
  • #55-01-0029: Allied Healthcare Carbolime Carbon Dioxide Absorbent - Drager Style Cartridge.
  • Drager Vapor 2000 Vaporizer:
    • #MFI-DGR-VAPOR-2000-ISO: Isoflurane.
    • #MFI-DGR-VAPOR-2000-SEVO: Sevoflurane.
  • #MFI-GEH-CARDIOCAP-5-BASIC: GE Cardiocap 5 Patient Monitor (No 5 agent gas analysis or CO2 included).
  • #MFI-POWER-CORD-USA-10FT: MFI Medical Universal Medical Grade Hospital Power Cord.
  • #R113P10: Maxtec MAX-11 Oxygen Cell.

Frequently asked questions

What types of patients can this anesthesia machine support?

The Drager Apollo Anesthesia Machine supports a wide range of patients due to its E-Vent plus servo-controlled high-speed piston ventilator. This technology, previously found only in ICU equipment, allows the machine to ventilate patients of any age and acuity.

How long does the integrated power backup last?

The Drager Apollo Anesthesia Machine includes an integrated power backup to maintain function during power interruptions.

  • It provides a guaranteed minimum runtime of 30 minutes.
  • The typical operational duration is approximately 90 minutes.

This duration is dependent on the specific ventilation parameters in use.

How does this machine help reduce the cost of anesthetic agents?

The Drager Apollo Anesthesia Machine features a unique Low-Flow Wizard that optimizes low and minimal flow settings. This advanced feature significantly helps in reducing the consumption and overall cost of inhalation anesthetic agents.

Is the self-test procedure fully automatic?

Yes, the Drager Apollo features a fully automatic self-test designed to enhance staff efficiency and provide immediate device status.

This automated procedure:

  • Typically lasts only three minutes upon startup.
  • Provides clear text directions for troubleshooting if needed.
  • Includes an integrated automatic leak test, ensuring total system leakage is less than 150 mL/min at 30 cmH2O.
What are the machine's dimensions and weight?

The Drager Apollo Anesthesia Machine has the following physical dimensions:

  • Height: 59 inches (150 cm)
  • Width: 33.5 inches (85 cm)
  • Depth: 31.5 inches (80 cm)

The weight of the unit is 365 lb (165 kg). Please note this weight measurement excludes any attached vaporizers or gas cylinders.

How does the integrated breathing system enhance safety and efficiency?

The Drager Apollo is equipped with an integrated breathing system designed to optimize clinical workflow. By eliminating external hoses and clutter, this integration significantly reduces the risks of misconnections and disconnections, thereby enhancing both patient safety and operational efficiency.

What clinical parameters does this machine monitor?

The Drager Apollo Anesthesia Machine features an integrated gas module and display, allowing for comprehensive monitoring of critical parameters without requiring external auxiliary monitors.

Standard Monitored Parameters:

  1. Gas and Agent Concentrations: Measures both inspiratory and expiratory concentrations of:
    • Oxygen (O2), Nitrous Oxide (N2O), and Carbon Dioxide (CO2)
    • Anesthetic Agents: Halothane, Enflurane, Isoflurane, Sevoflurane, and Desflurane
  2. Ventilation Mechanics:
    • Minute Volume (MV) and Tidal Volume (VT)
    • Breathing Frequency
    • Airway Pressures (Peak pressure, Plateau pressure, Mean pressure, and PEEP)
    • Patient Compliance (CPAT)

The system also provides standard waveform displays for CO2, O2, anesthetic agents, airway pressure, and inspiratory and expiratory flow.

What are the electrical power requirements?

The Drager Apollo Anesthesia Machine requires the following electrical specifications:

  • Power Source: 100 to 127 VAC (-15% + 10%), 45 to 65 Hz
  • Typical Consumption: 200 W

For added safety and reliability, the machine features an integrated power backup that provides a minimum of 30 minutes of operation, and typically up to 90 minutes, depending on the current ventilation parameters.

What is included with the Drager Apollo Anesthesia Machine?

The certified refurbished Drager Apollo Anesthesia Machine is shipped with essential components needed for operation, including:

  • Integrated Gas Module and Display: This module is built-in and provides monitoring for O2, N2O, CO2, and various anesthetic agents.
  • CO2 Absorption Container: A container of Sodasorb for use with the 1.5 L reusable canister absorber.
  • Sensors: An O2 sensor and two flow sensors.
  • Power & Backup: A power cord and two new batteries (providing up to 90 minutes of integrated backup power).
  • Software: The unit comes installed with Software version 04.53.05.

Please Note: To ensure complete clinical functionality, compatible Vaporizers and Patient Monitors are required, but they are sold separately from this base unit configuration.

Does it have advanced ventilation features?

The Drager Apollo Anesthesia Machine features a high-speed piston ventilator technology, the E-Vent plus, which is electrically driven and electronically controlled. This advanced system allows for precise control over ventilation parameters, similar to those found in ICU settings, ensuring optimal patient support.