Regular price$8,970.00 Sale price$6,329.23
Select a Voltage
Est. Delivery: 
<p>Earn%20[points_amount]%20when%20completing%20this%20purchase.</p>

Description

The CPAC RapidHeat RH-Pro9 HVHA Sterilizer includes three instrument trays, tray removal safety gloves, an instruction and care card, and a user manual.

Warranty: 3 Years - Parts and Labor.

The industry's most energy-efficient, medium-capacity sterilizer, the RH-Pro9 from CPAC is capable of fitting into most dental cabinets while still featuring three instrument trays to handle all your sterilization needs. Much like the larger RH-Pro11, the RH-Pro9 utilizes advanced HVHA (High-Velocity Hot Air) technology to provide the fastest instrument turnaround of any FDA-Cleared sterilization technology. No steam or water means no corrosion and a longer instrument life. It is simple and intuitive to use thanks to it's easy to operate touchscreen and you will also enjoy faster-processing and less maintenance and down time.

Features

CPAC RapidHeat RH-Pro9 HVHA Sterilizer Features

  • Waterless sterilization with no chemicals.
  • Non-corrosive sterilizer environment.
  • No steam. No drying. No corrosion. No maintenance.
  • Uses 85% less energy than steam.
  • More energy-efficient.
  • FDA-cleared 6 minute cycles (unwrapped).
  • FDA-cleared 12 minute cycles (wrapped).
  • Simple and easy touchscreen operation.
  • Faster-processing.
  • Less maintenance and down time.
  • Three large instrument trays.
  • Smaller cabinet-ready size (1,163 cubic inches). Fits easily into most dental cabinets.

Specifications

CPAC RapidHeat RH-Pro9 HVHA Sterilizer Specifications

  • Unit Size (OD): 19.6" W x 17.5" D x 13.3" H (498 x 445 x 338 mm).
  • Chamber Size (ID): 9.5" W x 15.6" D x 7.85" H (241 x 396 x 199 mm).
  • Chamber Capacity: 1,163 cubic inches (5 gal/19 liters).
  • Weight: 60 lb (27 kg).
  • Shipping Weight: 75 lb (34 kg).
  • Instrument Tray: 7.3" W x 12" D x 0.85" H.
  • Electrical:
    • 110-120 V, 60 Hz, 1400 Watts warm up, 300 Watts operating.
    • 220-240 V, 50 Hz, 1400 Watts warm up, 200 Watts operating.
    • TUV Electrical Safety/EMI.
    • CE Directive Compliance.
  • Sterilization Temperature: 375° F (190° C).
  • Safety: Meets Requirements of U.S. Electrical Safety Standards.
  • Sterilization Times:
    • Cycle 1: 6 minutes for unwrapped instruments.
    • Cycle 2: 8 minutes for hand pieces and medical drills.
    • Cycle 3: 12 minutes for wrapped, pouched instruments, trays, and cassettes.
  • Low Temperature Sterilization Times:
    • 320 degrees F: 36 minute cycle.
    • 300 degrees F: 56 minute cycle.
    • 280 degrees F: 126 minute cycle.
  • Instrument Capacity:
    • Unwrapped: 2.4 kg; 120 Dental Instruments.
    • Handpieces (Unwrapped): 15 Handpieces; 5 per Tray.
    • Wrapped Instruments: 2 kg; 8 Dental Instruments/Pouch; 4 Pouches/Tray; 3 Trays/Load. Total Instruments/Load: 96.
  • Wrapped Cassettes:
    • 5.5" x 8" x 1.5": 3 Cassettes (Total: 24 Instruments).
    • 6" x 8" x 1.5": 3 Cassettes (Total: 54 Instruments).
    • 8" x 11" x 1.5": No 8" x 11" Cassettes.
  • N95 FFR Mask Decontamination (175 degrees F): 30 minute cycle.

Voltages

CPAC RapidHeat RH-Pro9 HVHA Sterilizer Voltages

  • #RH-Pro9: 110 - 120 V.
  • #RH-Pro9-230V: 220 - 240 V.

Frequently asked questions

How fast are the sterilization cycle times?

The CPAC RapidHeat RH-Pro9 uses advanced High-Velocity Hot Air (HVHA) technology to deliver highly efficient, FDA-cleared sterilization cycles. By eliminating moisture and chemicals, it ensures your instruments are dry and ready for immediate use. The cycle times are as follows:

  • Unwrapped instruments: 6 minutes
  • Wrapped instruments: 12 minutes
  • Specialized N95 FFR mask decontamination: 30 minutes at 175° F

This system allows for a rapid instrument turnaround while simultaneously protecting your gear from the corrosion often caused by traditional steam sterilization methods.

Does it utilize advanced HVHA sterilization technology?

Yes, the CPAC RapidHeat RH-Pro9 utilizes High-Velocity Hot Air (HVHA) technology. This FDA-cleared, waterless, and chemical-free method is engineered for high-throughput environments, offering significant advantages over traditional steam sterilization systems.

Key Advantages of HVHA Sterilization

  • Fastest Turnaround: The RH-Pro9 provides efficient cycle times at a temperature of 375° F (190° C):
    • Unwrapped instruments: 6 minutes
    • Wrapped instruments: 12 minutes
  • Instrument Longevity: Because the process is waterless and chemical-free, it prevents the moisture-related corrosion and degradation often seen with steam autoclaves, effectively extending the lifespan of your instruments.
  • Superior Efficiency: The unit is highly energy-efficient, consuming 85% less energy compared to traditional steam sterilizers, while also reducing overall maintenance and operational downtime.
Is the sterilization process waterless and non-corrosive?

Yes, the CPAC RapidHeat RH-Pro9 utilizes advanced High-Velocity Hot Air (HVHA) technology, making the sterilization process completely waterless, chemical-free, and non-corrosive. This approach offers significant advantages over traditional steam sterilizers:

  • Extends Instrument Life: By eliminating steam and water, the unit prevents corrosion, helping to preserve the integrity and lifespan of your valuable instruments.
  • Energy Efficiency: The waterless operation results in high efficiency, using 85% less energy compared to typical steam sterilization methods.
  • Rapid Turnaround: This technology delivers the fastest FDA-cleared sterilization times, with cycles as short as 6 minutes for unwrapped instruments.
  • Reduced Maintenance: The lack of water and steam simplifies operation and significantly reduces required maintenance and downtime.
How many instrument trays are included?

The CPAC RapidHeat RH-Pro9 Sterilizer is shipped complete with the necessary accessories for immediate operation.

The package includes:

  • Three instrument trays (each sized 7.3” W x 12” D x 0.85” H) for versatile loading of instruments and cassettes.
  • Tray removal safety gloves for safe handling of hot materials after the sterilization cycle.
  • Instruction and care card
  • User manual
Does the sterilizer offer N95 mask decontamination?

Yes, the CPAC RapidHeat RH-Pro9 includes a specialized, low-temperature cycle for N95 FFR mask decontamination utilizing its High-Velocity Hot Air (HVHA) technology.

This dedicated cycle operates with the following specifications:

  • Temperature: 175° F
  • Cycle Time: 30 minutes
Is this sterilizer fully certified for safety?

Yes, the CPAC RapidHeat RH-Pro9 HVHA Sterilizer is designed with safety in mind. It meets the requirements of U.S. Electrical Safety Standards and holds TUV Electrical Safety/EMI and CE Directive Compliance certifications.

What is the maximum wrapped instrument capacity?

The CPAC RapidHeat RH-Pro9 is a medium-capacity sterilizer that includes three large instrument trays. It offers generous capacity for wrapped loads, accommodating both pouches and cassettes.

Here are the maximum wrapped capacities:

  • Wrapped Instrument Pouches:
    • Maximum Load: 3 trays
    • Total Instruments: 96 dental instruments (based on 4 pouches per tray)
    • Maximum Weight: 2 kg
  • Wrapped Cassettes: The sterilizer can accommodate a maximum of 3 wrapped cassettes per load.
    • 5.5” x 8” x 1.5” Cassettes: Total of 24 instruments.
    • 6” x 8” x 1.5” Cassettes: Total of 54 instruments.
Does the sterilizer have a cabinet-ready size?

Yes, the CPAC RapidHeat RH-Pro9 is engineered with a Cabinet Ready Size specifically to fit conveniently within most standard dental and medical cabinets, optimizing your workspace.

The compact external dimensions (OD) of the unit are:

  • Width: 19.6 inches
  • Depth: 17.5 inches
  • Height: 13.3 inches

Despite its small footprint, it offers a medium capacity with a substantial chamber volume of 1,163 cubic inches (19 liters) and accommodates the three large instrument trays included.

What is the operating temperature of the RapidHeat sterilizer?

The CPAC RapidHeat RH-Pro9 utilizes advanced High-Velocity Hot Air (HVHA) technology to achieve efficient, waterless sterilization. The primary sterilization cycle operates at a consistent temperature of 375° F (190° C).

This high-heat, moisture-free process is specifically designed to prevent corrosion and extend the life of your instruments. Additionally, the unit features a dedicated N95 FFR Mask Decontamination cycle that operates at 175° F (80° C) for a 30-minute duration.

Does the sterilizer have an intuitive touchscreen?

Yes, the CPAC RapidHeat RH-Pro9 is equipped with a simple and easy-to-use touchscreen interface. This design choice ensures:

  • Streamlined Operation: The intuitive display simplifies cycle selection and monitoring.
  • Reduced Downtime: Easy operation and the non-corrosive, waterless technology contribute to less maintenance and maximum uptime.