Sale price$341.44
Select a Size
Est. Delivery: 
%3Cp%3EEarn%20[points_amount]%20when%20you%20buy%20this%20item.%3C/p%3E

Shop with Confidence

+
+
+

Description

The ConMed Backpad Electrode (50 / Case) provides a unique one-piece disposable monitoring system that minimizes patient set-up time, prevents leadwires from tangling, and reduces the risk of cross contamination or hospital acquired infections.

It is designed for placement on the patient's back for maximum exposure to the chest area. Application is a simple, one step process of placing the pre-gelled backpad onto the patient's skin.

Features

ConMed Backpad Electrode Features

  • Uses a dense, low profile foam substrate that conforms to the patient's skin while reducing fluid absorption. This foam substrate is coated with an acrylic adhesive that keeps the ECG Backpad in place, even when it is exposed to O.R. prep solutions.
  • Embedded within the foam, are four radiolucent electrode sensors (representing the four limb leads) coated with silver/silver chloride for maximum signal performance. The sensors are covered with a conductive adhesive hydrogel to ensure quick signal retention.
  • Pre-attached to the electrode array (to ease the application), is a low profile, 28" (71 cm) bonded leadwire system.
  • The leadwire system terminates to a durable, one-piece molex style connector (that is compatible only with ConMed ECG Backpad Cables.
  • Specialty adapters available for five lead monitoring and ease in conversion to R series safety leadwires.
  • Not made with natural rubber latex to protect against possible latex sensitivity issues.

Specifications

ConMed Backpad Electrode Specifications

Parameter Adult Backpad (#01-3130) Infant Backpad (#01-4130)
Basepad Closed cell polyethylene foam Closed cell polyethylene foam
Basepad Size 6.5" x 7.5" (16.5 cm x 19 cm) 3.5" x 6.0" (8.9 cm x 16.24 cm)
Gel 5% KCI 5% KCI
Flex Circuit Silver/Silver Chloride (Ag/AgCl) Silver/Silver Chloride (Ag/AgCl)
Adhesion Medical grade acrylic adhesive Medical grade acrylic adhesive
Carrier Silicone coated paper Silicone coated paper
Shelf Life 24 months from date of manufacture 24 months from date of manufacture
Electrical DC Offset 0.0 mV 0.6 mV
AC Impedance 85 104
Defib Recovery 10.9 mV 12.5 mV
Recovery Rate 0.3 mV / second 0.2 mV / second
Shipping Dimensions 19" x 12" x 9" (48.3 cm x 30.5 cm x 22.9 cm) 14" x 9" x 9" (35.6 cm x 22.9 cm x 22.9 cm)
Shipping Weight 5 lb (2.3 kg) 3.4 lb (1.5 kg)

Frequently asked questions

How does the one-piece backpad simplify ECG setup?

The ConMed Backpad Electrode is engineered as a one-piece disposable monitoring system to significantly streamline patient setup and enhance workflow in multi-lead ECG monitoring. It simplifies the process in the following key ways:

  • Minimized Setup Time: The pre-gelled, disposable design allows for simple, one-step application directly onto the patient’s back.
  • Clutter-Free Monitoring: It utilizes a pre-attached, low-profile 28-inch (71 cm) bonded leadwire system which prevents leadwire tangling and simplifies overall handling.
  • Reduced Contamination Risk: As a single-use, disposable system, it helps mitigate the risk of cross-contamination and hospital-acquired infections.
  • Reliable Signal Acquisition: Four integrated Silver/Silver Chloride (Ag/AgCl) sensors and conductive adhesive hydrogel ensure quick signal retention and maximum performance.
  • Superior Adhesion: Medical-grade acrylic adhesive ensures the pad remains securely in place, even when exposed to Operating Room prep solutions.
Does this backpad reduce cross-contamination risk?

Yes, the ConMed Backpad Electrode is specifically designed as a one-piece, disposable system to minimize the risk of cross-contamination and support strict infection control protocols.<ul><li>Disposable Unit: As a single-use product, it aids in preventing the transfer of pathogens between patients.</li><li>One-Piece Design: This system simplifies patient setup and minimizes handling time, further reducing potential clinical risks associated with complex multi-component setups.</li></ul>

Does the electrode backpad provide superior signal performance?

Yes, the ConMed Backpad Electrode is specifically engineered for superior signal performance and reliable continuous ECG monitoring. The design maximizes signal integrity through several key features:

  • High-Quality Sensors: It utilizes four radiolucent electrode sensors coated with Silver/Silver Chloride (Ag/AgCl), which is essential for maximizing signal stability and acquisition.
  • Rapid Contact: A specialized conductive adhesive hydrogel is pre-applied to ensure quick signal retention upon patient contact.
  • Exceptional Stability: The Adult variant offers outstanding electrical stability, featuring an Electrical DC Offset of 0.0 mV, which minimizes baseline drift during continuous monitoring.
  • Secure Adhesion: The low-profile foam substrate uses a durable medical-grade acrylic adhesive, ensuring secure conformity to the patient’s skin. This strong adhesion resists O.R. prep solutions, helping to prevent motion artifacts and maintain consistent signal contact.
Are different patient sizes available?

Yes, the ConMed Backpad Electrode is available in two distinct sizes—Adult and Infant—to ensure optimal fit and signal quality for different patient populations. Each case includes 50 electrodes.

The specific dimensions for the basepad size are:

  • Adult Variant: 6.5” x 7.5” (16.5 cm x 19 cm)
  • Infant Variant: 3.5” x 6.0” (8.9 cm x 16.24 cm)

It is important to note that the electrical specifications (such as AC Impedance and DC Offset) are individually calibrated for each size to guarantee superior signal performance specific to that patient group.

How many electrodes are included per case?

The ConMed Backpad Electrodes are packaged with 50 units per case.

Is the ConMed Backpad Electrode made with latex?

No, the ConMed Backpad Electrode is not made with natural rubber latex, minimizing the risk of latex sensitivity issues for patients.

How long is the pre-attached leadwire?

The ConMed Backpad Electrode includes a pre-attached, low-profile, bonded leadwire system that measures 28 inches (71 cm) in length. This integrated, disposable system is designed to streamline clinical workflow by simplifying patient setup and minimizing leadwire tangling. The leadwire terminates in a durable, proprietary Molex-style connector that is compatible only with ConMed ECG Backpad Cables.

Is the medical-grade adhesive secure?

Yes, the ConMed Backpad Electrode is designed for superior and stable adhesion throughout continuous monitoring.

Key features ensuring reliable placement include:

  • Medical-Grade Acrylic Adhesive: This robust adhesive provides strong, long-lasting adherence to the skin.
  • Resistance to Prep Solutions: The low-profile foam substrate and acrylic adhesive are specifically engineered to resist fluid absorption, maintaining secure placement even when exposed to operating room (O.R.) prep solutions.
  • Conforming Substrate: The closed cell polyethylene foam basepad conforms easily to the patient’s back, ensuring consistent contact for stable signal acquisition.
Does the ConMed Backpad Electrode have a long shelf life?

Yes, the ConMed Backpad Electrode has a shelf life of 24 months from the date of manufacture, ensuring a long usability period.

Does the one-piece system simplify patient setup?

Yes, the ConMed Backpad Electrode is specifically designed as a one-piece, disposable monitoring system to significantly streamline clinical workflow and patient setup. It is a key selling point intended for rapid application.

Key benefits that simplify the monitoring process include:

  • Rapid Application: The system is pre-gelled and applied in one simple step, which drastically reduces the time needed for patient setup.
  • Minimized Tangling: It incorporates a pre-attached, low-profile 28-inch (71 cm) bonded leadwire system, eliminating the logistical issues and tangling associated with separate leadwires.
  • Infection Control: As a single-use disposable unit, it helps minimize the risk of cross-contamination.
  • Consistent Quality: It features four radiolucent Silver/Silver Chloride (Ag/AgCl) sensors embedded in the basepad for superior signal performance immediately upon placement.